233 lines
7.8 KiB
INI
233 lines
7.8 KiB
INI
|
; Portions Copyright (c) 1996-2001 National Semiconductor Corp.
|
||
|
; Copyright (c) 1996-2001 Microsoft Corporation.
|
||
|
|
||
|
; This INF is designed for installation as part of the NT CD. To change it to
|
||
|
; floppy based install, comment out any lines ending with "; CD only"
|
||
|
; and uncomment all lines ending with "; floppy only"
|
||
|
|
||
|
[Version]
|
||
|
Signature = "$Windows NT$"
|
||
|
Provider = %NSC%
|
||
|
Class = Infrared
|
||
|
ClassGUID = {6bdd1fc5-810f-11d0-BEC7-08002BE2092F}
|
||
|
DriverVer = 05/24/2001, 1.0.0.0
|
||
|
CatalogFile = delta.cat
|
||
|
|
||
|
[SourceDisksNames] ; floppy only
|
||
|
1 = %MediaDescription%,, ; floppy only
|
||
|
|
||
|
[SourceDisksFiles] ; floppy only
|
||
|
nscirda.sys = 1 ; floppy only
|
||
|
|
||
|
[DestinationDirs]
|
||
|
;
|
||
|
; Specify destination directories for groups of files.
|
||
|
; '12' indicates the Windows drivers directory.
|
||
|
; '17' indicates the Windows Inf directory.
|
||
|
;
|
||
|
DefaultDestDir=12
|
||
|
|
||
|
[NSC_CopySys]
|
||
|
;
|
||
|
; This section lists the source and destination names of files that need
|
||
|
; to be copied to the user's drive. The destination directory is given
|
||
|
; in the [DestinationDirs] section above.
|
||
|
;
|
||
|
nscirda.sys,,,2 ; Do not Skip File
|
||
|
|
||
|
[ControlFlags]
|
||
|
ExcludeFromSelect= *NSC6001
|
||
|
|
||
|
|
||
|
[Manufacturer]
|
||
|
;
|
||
|
; Specify a name and devices section for each supported manufacturer that
|
||
|
; makes products of this class.
|
||
|
;
|
||
|
%NSC% = NSC_Devices
|
||
|
|
||
|
[NSC_Devices]
|
||
|
;
|
||
|
; This section describes the devices of this class made by a particular
|
||
|
; manufacturer.
|
||
|
; The first descriptor, delimited by '%', is a symbolic string whose actual
|
||
|
; value is given in the [Strings] section below.
|
||
|
;
|
||
|
%NSC6001.DeviceDesc% = NSC6001_ndi, *NSC6001 ; Generic NSC driver
|
||
|
|
||
|
|
||
|
[NSC6001_ndi]
|
||
|
DelReg = NSC_DelReg
|
||
|
AddReg = NSC_AddReg,*NSC6001_AddReg,Dongle_Addreg,Speed_Addreg,Help_AddReg
|
||
|
BusType = 1
|
||
|
Characteristics = 0x4 ; NCF_PHYSICAL
|
||
|
CopyFiles = NSC_CopySys
|
||
|
|
||
|
[NSC6001_ndi.Services]
|
||
|
AddService= NSCIRDA, 2, NSCIRDA.AddService, common.EventLog
|
||
|
|
||
|
[NSC6001_ndi.Coinstallers]
|
||
|
DelReg=NSC_DelCoinstallers
|
||
|
|
||
|
|
||
|
|
||
|
|
||
|
[NSC_AddReg]
|
||
|
; Interfaces
|
||
|
HKR, Ndi, Service, 0, "NSCIRDA"
|
||
|
HKR, NDI\Interfaces, DefUpper, 0, ndisirda
|
||
|
HKR, NDI\Interfaces, UpperRange, 0, ndisirda
|
||
|
HKR, Ndi\Interfaces, DefLower, 0, nolower
|
||
|
HKR, Ndi\Interfaces, LowerRange, 0, nolower
|
||
|
HKR, Ndi, RequiredAll, 0, "MS_IrDA"
|
||
|
|
||
|
[*NSC6001_AddReg]
|
||
|
HKR,,BoardType,0,"3"
|
||
|
HKR,NDI\params\Dongle_A_Type,default,,"1"
|
||
|
HKR,NDI\params\MaxConnectRate,default,,"4000000"
|
||
|
|
||
|
|
||
|
[Dongle_Addreg]
|
||
|
;
|
||
|
; These entries allow the user to select the Configuration Register
|
||
|
; Base Address that the IR108 driver uses from network properties
|
||
|
; dialog box AFTER INSTALLATION (under the 'Advanced' options).
|
||
|
; The user's selection is recorded in the registry and then read out
|
||
|
; by the nscirda.sys driver at boot time.
|
||
|
;
|
||
|
|
||
|
HKR,NDI\params\Dongle_A_Type,ParamDesc,,%Dongle_A%
|
||
|
HKR,NDI\params\Dongle_A_Type,flag,1,20,00,00,00
|
||
|
;HKR,NDI\params\Dongle_A_Type,default,,"5"
|
||
|
HKR,NDI\params\Dongle_A_Type,type,,enum
|
||
|
HKR,NDI\params\Dongle_A_Type\enum,"0",,%DongleType_0%
|
||
|
HKR,NDI\params\Dongle_A_Type\enum,"1",,%DongleType_1%
|
||
|
HKR,NDI\params\Dongle_A_Type\enum,"2",,%DongleType_2%
|
||
|
HKR,NDI\params\Dongle_A_Type\enum,"3",,%DongleType_3%
|
||
|
HKR,NDI\params\Dongle_A_Type\enum,"4",,%DongleType_4%
|
||
|
HKR,NDI\params\Dongle_A_Type\enum,"5",,%DongleType_5%
|
||
|
HKR,NDI\params\Dongle_A_Type\enum,"6",,%DongleType_6%
|
||
|
HKR,NDI\params\Dongle_A_Type\enum,"7",,%DongleType_7%
|
||
|
HKR,NDI\params\Dongle_A_Type\enum,"8",,%DongleType_8%
|
||
|
HKR,NDI\params\Dongle_A_Type\enum,"9",,%DongleType_9%
|
||
|
HKR,NDI\params\Dongle_A_Type\enum,"10",,%DongleType_10%
|
||
|
HKR,NDI\params\Dongle_A_Type\enum,"11",,%DongleType_11%
|
||
|
|
||
|
HKR,NDI\params\Dongle_B_Type,ParamDesc,,%Dongle_B%
|
||
|
HKR,NDI\params\Dongle_B_Type,flag,1,20,00,00,00
|
||
|
HKR,NDI\params\Dongle_B_Type,default,,"0"
|
||
|
HKR,NDI\params\Dongle_B_Type,type,,enum
|
||
|
HKR,NDI\params\Dongle_B_Type\enum,"0",,%DongleType_0%
|
||
|
HKR,NDI\params\Dongle_B_Type\enum,"1",,%DongleType_1%
|
||
|
HKR,NDI\params\Dongle_B_Type\enum,"2",,%DongleType_2%
|
||
|
HKR,NDI\params\Dongle_B_Type\enum,"3",,%DongleType_3%
|
||
|
HKR,NDI\params\Dongle_B_Type\enum,"4",,%DongleType_4%
|
||
|
HKR,NDI\params\Dongle_B_Type\enum,"5",,%DongleType_5%
|
||
|
HKR,NDI\params\Dongle_B_Type\enum,"6",,%DongleType_6%
|
||
|
HKR,NDI\params\Dongle_B_Type\enum,"7",,%DongleType_7%
|
||
|
HKR,NDI\params\Dongle_B_Type\enum,"8",,%DongleType_8%
|
||
|
HKR,NDI\params\Dongle_B_Type\enum,"9",,%DongleType_9%
|
||
|
HKR,NDI\params\Dongle_B_Type\enum,"10",,%DongleType_10%
|
||
|
HKR,NDI\params\Dongle_B_Type\enum,"11",,%DongleType_11%
|
||
|
|
||
|
[Speed_Addreg]
|
||
|
;
|
||
|
; These entries allow the user to select the Configuration Register
|
||
|
; Base Address that the IR108 driver uses from network properties
|
||
|
; dialog box AFTER INSTALLATION (under the 'Advanced' options).
|
||
|
; The user's selection is recorded in the registry and then read out
|
||
|
; by the nscirda.sys driver at boot time.
|
||
|
;
|
||
|
|
||
|
HKR,NDI\params\MaxConnectRate,ParamDesc,,%MaxConnectRate%
|
||
|
HKR,NDI\params\MaxConnectRate,type,,enum
|
||
|
HKR,NDI\params\MaxConnectRate\enum,"4000000",,"4,000,000 bps"
|
||
|
HKR,NDI\params\MaxConnectRate\enum,"1152000",,"1,152,000 bps"
|
||
|
HKR,NDI\params\MaxConnectRate\enum,"115200",, " 115,200 bps"
|
||
|
HKR,NDI\params\MaxConnectRate\enum,"57600",, " 57,600 bps"
|
||
|
HKR,NDI\params\MaxConnectRate\enum,"38400",, " 38,400 bps"
|
||
|
HKR,NDI\params\MaxConnectRate\enum,"19200",, " 19,200 bps"
|
||
|
HKR,NDI\params\MaxConnectRate\enum,"9600",, " 9,600 bps"
|
||
|
|
||
|
[TurnAroundTime_Addreg]
|
||
|
; Turnaround time will be used by future version of the driver.
|
||
|
;
|
||
|
; These entries allow the user to select the Minimum Turn Around Time.
|
||
|
; The default value is 1000 microseconds (1 ms)
|
||
|
; The selection is given using under the 'Advanced' options
|
||
|
; The user's selection is recorded in the registry and then read out
|
||
|
; by the nscirda.sys driver at boot time.
|
||
|
;
|
||
|
HKR,NDI\params\MinimumTurnAroundTime,ParamDesc,,%TurnaroundTime%
|
||
|
HKR,NDI\params\MinimumTurnAroundTime,flag,1,20,00,00,00
|
||
|
HKR,NDI\params\MinimumTurnAroundTime,type,,enum
|
||
|
HKR,NDI\params\MinimumTurnAroundTime,default,,"1000" ; 1 ms
|
||
|
HKR,NDI\params\MinimumTurnAroundTime\enum,"10000",,"10 ms"
|
||
|
HKR,NDI\params\MinimumTurnAroundTime\enum,"5000",," 5 ms"
|
||
|
HKR,NDI\params\MinimumTurnAroundTime\enum,"1000",," 1 ms"
|
||
|
HKR,NDI\params\MinimumTurnAroundTime\enum,"500",," 0.5 ms"
|
||
|
HKR,NDI\params\MinimumTurnAroundTime\enum,"100",," 0.1 ms"
|
||
|
|
||
|
[Help_Addreg]
|
||
|
HKR,NDI,HelpText,0,%IRMINI_HELP%
|
||
|
|
||
|
[NSC_DelReg]
|
||
|
HKR,,EnumPropPages32
|
||
|
|
||
|
[NSC_DelCoinstallers]
|
||
|
HKR,,CoInstallers32
|
||
|
|
||
|
[NSCIRDA.AddService]
|
||
|
DisplayName = %NSCIRDA.ServiceDesc%
|
||
|
ServiceType = 1 ; %SERVICE_KERNEL_DRIVER%
|
||
|
StartType = 3 ; %SERVICE_DEMAND_START%
|
||
|
ErrorControl = 1 ; %SERVICE_ERROR_NORMAL%
|
||
|
ServiceBinary = %12%\nscirda.sys ;12=drivers directory
|
||
|
LoadOrderGroup = NDIS
|
||
|
|
||
|
[common.EventLog]
|
||
|
AddReg = common.AddEventLog.reg
|
||
|
|
||
|
[common.AddEventLog.reg]
|
||
|
HKR, , EventMessageFile, 0x00020000, "%%SystemRoot%%\System32\netevent.dll"
|
||
|
HKR, , TypesSupported, 0x00010001, 7
|
||
|
|
||
|
|
||
|
|
||
|
[Strings]
|
||
|
;
|
||
|
; This section defines symbolic string constants for use in the rest
|
||
|
; of the .inf script. You should create and use symbols for all
|
||
|
; translatable strings in order to make localization easier.
|
||
|
; Also, spaces within strings elsewhere in the script confuse infedit.exe;
|
||
|
; so use symbolic constants for any multi-word strings.
|
||
|
;
|
||
|
MediaDescription = "Sample IrDA miniport install disk"
|
||
|
|
||
|
IRMINI_HELP="The IrDA infrared port. It can be used to establish wireless serial and network links to other computers."
|
||
|
NSCIRDA.ServiceDesc="NSC Infrared Device Driver"
|
||
|
NSC6001.DeviceDesc="IrDA Fast Infrared Port(Sample)"
|
||
|
|
||
|
V_CLASSNAME="Infrared adapters"
|
||
|
|
||
|
NSC="National Semiconductor"
|
||
|
|
||
|
Dongle_A="Infrared Transceiver A"
|
||
|
Dongle_B="Infrared Transceiver B"
|
||
|
|
||
|
DongleType_0="SIR Transceiver"
|
||
|
DongleType_1="HP HSDL-1100/2100"
|
||
|
DongleType_2="HP HSDL-2300/3600"
|
||
|
DongleType_3="IBM 31T1100"
|
||
|
DongleType_4="Sharp RY5HD01/KD01"
|
||
|
DongleType_5="Sharp RY6FD11E"
|
||
|
DongleType_6="Vishay TFDS-6000"
|
||
|
DongleType_7="Vishay TFDS-6500"
|
||
|
DongleType_8="Siemens IRMS/T6400"
|
||
|
DongleType_9="TI TSLM1100"
|
||
|
DongleType_10="IBM SC-20H2987"
|
||
|
DongleType_11="Dell T-97"
|
||
|
|
||
|
MaxConnectRate="Maxiumum Connect Rate"
|
||
|
TurnaroundTime="Minimum Turn Around Time"
|