windows-nt/Source/XPSP1/NT/net/snmp/mibs/printmib.mib

3552 lines
133 KiB
Plaintext
Raw Normal View History

2020-09-26 03:20:57 -05:00
Printer-MIB DEFINITIONS ::= BEGIN
--
-- Microsoft extracted from RFC1759 and made one change only:
-- line 3033 changed from MAX-ACCESS not-accessible to MAX-ACCESS read-only
--
IMPORTS
MODULE-IDENTITY,OBJECT-TYPE,experimental,Counter32,Integer32,TimeTicks,NOTIFICATION-TYPE,OBJECT-IDENTITY FROM SNMPv2-SMI
TEXTUAL-CONVENTION FROM SNMPv2-TC
MODULE-COMPLIANCE,OBJECT-GROUP FROM SNMPv2-CONF
hrDeviceIndex,hrStorageIndex FROM HOST-RESOURCES-MIB;
printmib MODULE-IDENTITY
LAST-UPDATED "9411250000Z"
ORGANIZATION "IETF Printer MIB Working Group"
CONTACT-INFO
" Steven Waldbusser
Postal: Carnegie Mellon University
4910 Forbes Ave
Pittsburgh, PA, 15213
Tel: 412-268-6628
Fax: 412-268-4987
E-mail: waldbusser@cmu.edu"
DESCRIPTION
"The MIB module for management of printers."
::= { mib-2 43 }
-- Textual conventions for this MIB module
MediaUnit ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Units of measure for media dimensions."
-- This is a type 1 enumeration.
SYNTAX INTEGER {
tenThousandthsOfInches(3), -- .0001
micrometers(4)
}
CapacityUnit ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Units of measure for media capacity."
-- This is a type 1 enumeration.
SYNTAX INTEGER {
tenThousandthsOfInches(3), -- .0001
micrometers(4),
sheets(8),
feet(16),
meters(17)
}
SubUnitStatus ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Status of a printer sub-unit.
The SubUnitStatus is an integer that is the sum of 5
distinct values, Availability, Non-Critical, Critical,
On-line, and Transitioning. These values are:
Availability value
Available and Idle 0 000'b
Available and Standby 2 010'b
Available and Active 4 100'b
Available and Busy 6 110'b
Unavailable and OnRequest 1 001'b
Unavailable because Broken 3 011'b
Unknown 5 101'b
Non-Critical
No Non-Critical Alerts 0
Non-Critical Alerts 8
Critical
No Critical Alerts 0
Critical Alerts 16
On-Line
Intended state is On-Line 0
Intended state is Off-Line 32
Transitioning
At intended state 0
Transitioning to intended state 64
"
SYNTAX INTEGER (0..126)
PresentOnOff ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Presence and configuration of a device or feature."
-- This is a type 1 enumeration.
SYNTAX INTEGER {
other(1),
on(3),
off(4),
notPresent(5)
}
CodedCharSet ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A coded character set value that specifies both a set of
characters that may be used and an encoding (as one or more
octets) that is used to represent the characters in the
set. These values are to be used to identify the encoding
employed for strings in the MIB where this is not fixed by
the MIB.
Some objects that allow a choice of coded character set
are: the prtLocalizationCharacterSet object in the
LocalizationTable and prtInterpreterDefaultCharSetIn.
The prtGeneralCurrentLocalization and prtConsoleLocalization
objects in turn contain the index in the LocalizationTable
of the current localization (country, language, and coded
character set) of the `description' objects and the console,
respectively.
The space of the coded character set enumeration has been
divide into three regions. The first region (3-999) consists
of coded character sets that have been standardized by some
standard setting organization. This region is intended for
standards that do not have subset implementations. The
second region (1000-1999) is for the Unicode and ISO/IEC 10646
coded character sets together with a specification of a (set
of) sub-repetoires that may occur. The third region (>1999)
is intended for vendor specific coded character sets.
NOTE: Unicode and ISO 10646 character coded data may be
processed and stored in either Big Endian (most significant
octet first) or Little Endian (least significant octet
first) order. Intel x86, VAX, and Alpha/AXP architectures are
examples of Little Endian processor architectures.
Furthermore, in environments where either order may occur,
so-called Unicode BYTE ORDER MARK (BOM) character (which is
ISO 10646 ZERO WIDTH NO BREAK SPACE), coded as FEFF in two
octets and 0000FEFF in four octets is used at the beginning
of the data as a signature to indicate the order of the
following data (See ISO 10646 Annex F). Thus either
ordering and BOM may occur in print data streams sent to the
interpreter. However, ISO 8824/8825 (ASN.1/BER) used by
SNMP is quite clear that Big Endian order shall be used and
BOM shall NOT be used in transmission in the protocol.
Transmitting Unicode in Big Endian order in SNMP should
not prove to be a hardship for Little Endian machines,
since SNMP ASN.1/BER requires integers to be transmitted
in Big Endian order as well. So SNMP implementations on
Little Endian machines are already reversing the order of
integers to make them Big Endian for transmission via
SNMP. Also Unicode characters are usually treated as
two-octet integers, not short text strings, so that it will
be straightforward for Little Endian machines to reverse the
order of Unicode character octets as well before
transmitting them and after receiving them via the SNMP
protocol.
Where a given coded character set may be known by more than
one name, the most commonly known name is used as the name
of the enumeration and other names are shown in the
comments. The comments also indicate where to find detailed
information on the coded character set and briefly
characterize its relationship to other similar coded
character sets.
The current list of character sets and their enumerated
values used to reference them is contained in the IANA
Character Set registry. The enum value is indicated by
the MIBenum entry in the registry. The enum symbol is
indicated by the Alias that starts with `cs' for character
set.
The IANA character sets registry is available via
anonymous ftp.
The ftp server is ftp.isi.edu.
The subdirectory is /in-notes/iana/assignments/.
The file name is character-sets.
To add a character set to the IANA Registry:
1. Format an entry like those in the current list,
omitting the MIBenum value.
2. Send the entry with a request to add the entry
to the character set list to iana@ISI.EDU.
3. The IANA will supply a unique MIBenum value
and update the list."
-- This is a type 3 enumeration.
SYNTAX INTEGER {
other(1) -- used if the designated coded
-- character set is not currently in
-- the enumeration
-- See IANA Registry for standard character sets in the
-- MIBenum range of 3-999.
-- See IANA Registry for Unicode and vendor-supplied
-- combinations of ISO collections and character sets based
-- on Unicode in the MIBenum range of 1000-1999.
-- See IANA Registry for vendor developed character sets
-- in the MIBenum range of 2000-xxxx.
}
-- The General Printer Group
--
-- The general printer sub-unit is responsible for the overall control
-- and status of the printer. There is exactly one general printer
-- sub-unit in a printer.
--
-- Implementation of every object in this group is mandatory.
prtGeneral OBJECT IDENTIFIER ::= { printmib 5 }
prtGeneralTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtGeneralEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of general information per printer.
Objects in this table are defined in various
places in the MIB, nearby the groups to
which they apply. They are all defined
here to minimize the number of tables that would
otherwise need to exist."
::= { prtGeneral 1 }
prtGeneralEntry OBJECT-TYPE
SYNTAX PrtGeneralEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry exists in this table for each
device entry in the hostmib device table who's type
is `printer'"
INDEX { hrDeviceIndex }
::= { prtGeneralTable 1 }
PrtGeneralEntry ::= SEQUENCE {
-- Note that not all of the objects in this sequence are in the
-- general printer group.
prtGeneralConfigChanges Counter32,
prtGeneralCurrentLocalization Integer32,
prtGeneralReset INTEGER,
prtGeneralCurrentOperator OCTET STRING,
prtGeneralServicePerson OCTET STRING,
prtInputDefaultIndex Integer32,
prtOutputDefaultIndex Integer32,
prtMarkerDefaultIndex Integer32,
prtMediaPathDefaultIndex Integer32,
prtConsoleLocalization Integer32,
prtConsoleNumberOfDisplayLines Integer32,
prtConsoleNumberOfDisplayChars Integer32,
prtConsoleDisable INTEGER
}
prtGeneralConfigChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts configuration changes that change the capabilities of
a printer, such as the addition/deletion of input/output bins,
the addition/deletion of interpreters, or changes in media
size. Such changes will often affect the capability of the
printer to service certain types of print jobs.
Management applications may cache infrequently changed
configuration information about sub-units on the printer.
This object should be incremented whenever the agent wishes
such applications to invalidate that cache and re-download
all of this configuration information, thereby signalling a
change in the printer's configuration.
For example, if an input tray that contained paper of
different dimensions was added, this counter would be
incremented.
As an additional example, this counter would not be
incremented when an input tray is removed or the level of an
input device changes."
::= { prtGeneralEntry 1 }
prtGeneralCurrentLocalization OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the prtLocalizationIndex corresponding to the
current language, country, and character set to be used for
localized string values that are identified as being dependent
on the value of this object. Note that this object does not
apply to localized strings in the prtConsole group or any
object that is not identified as above."
::= { prtGeneralEntry 2 }
prtGeneralReset OBJECT-TYPE
-- This value is a type 3 enumeration
SYNTAX INTEGER {
notResetting(3),
powerCycleReset(4), -- Cold Start
resetToNVRAM(5), -- Warm Start
resetToFactoryDefaults(6) -- Reset contents of
-- NVRAM to factory defaults
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this value to `powerCycleReset', `resetToNVRAM', or
`resetToFactoryDefaults' will result in the resetting of the
printer. When read, this object will always have the value
`notResetting(3)', and a SET of the value `notResetting' shall
have no effect on the printer. Some of the defined values are
optional. However, every implementation must support at least
the values `notResetting' and resetToNVRAM'."
::= { prtGeneralEntry 3 }
-- The Cover Table
--
-- The cover portion of the General print sub-unit describes the
-- covers and interlocks of the printer. The Cover Table has an
-- entry for each cover and interlock.
prtCover OBJECT IDENTIFIER ::= { printmib 6 }
prtCoverTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtCoverEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the covers and interlocks of the printer."
::= { prtCover 1 }
prtCoverEntry OBJECT-TYPE
SYNTAX PrtCoverEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a cover or interlock.
Entries may exist in the table for each device
index whose device type is `printer'."
INDEX { hrDeviceIndex, prtCoverIndex }
::= { prtCoverTable 1 }
PrtCoverEntry ::= SEQUENCE {
prtCoverIndex Integer32,
prtCoverDescription OCTET STRING,
prtCoverStatus INTEGER
}
prtCoverIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this Cover
sub-unit. Although these values may change due to a major
reconfiguration of the device (e.g. the addition of new
cover sub-units to the printer), values are expected to
remain stable across successive printer power cycles."
::= { prtCoverEntry 1 }
prtCoverDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The manufacturer provided cover sub-mechanism name in the
localization specified by prtGeneralCurrentLocalization."
::= { prtCoverEntry 2 }
prtCoverStatus OBJECT-TYPE
-- This value is a type 2 enumeration
SYNTAX INTEGER {
other(1),
doorOpen(3),
doorClosed(4),
interlockOpen(5),
interlockClosed(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of this cover sub-unit."
::= { prtCoverEntry 3 }
-- The Localization Table
--
-- The localization portion of the General printer sub-unit is
-- responsible for identifying the natural language, country, and
-- character set in which character strings are expressed. There
-- may be one or more localizations supported per printer. The
-- available localizations are represented by the Localization table.
prtLocalization OBJECT IDENTIFIER ::= { printmib 7 }
prtLocalizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtLocalizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The available localizations in this printer."
::= { prtLocalization 1 }
prtLocalizationEntry OBJECT-TYPE
SYNTAX PrtLocalizationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A description of a localization.
Entries may exist in the table for each device
index who's device type is `printer'."
INDEX { hrDeviceIndex, prtLocalizationIndex }
::= { prtLocalizationTable 1 }
PrtLocalizationEntry ::= SEQUENCE {
prtLocalizationIndex Integer32,
prtLocalizationLanguage OCTET STRING,
prtLocalizationCountry OCTET STRING,
prtLocalizationCharacterSet CodedCharSet
}
prtLocalizationIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this
localization entry. Although these values may change due to a
major reconfiguration of the device (e.g., the addition of new
Cover sub-units to the printer), values are expected to remain
stable across successive printer power cycles."
::= { prtLocalizationEntry 1 }
prtLocalizationLanguage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A two character language code from ISO 639. Examples EN, GB,
CA, FR, DE."
::= { prtLocalizationEntry 2 }
prtLocalizationCountry OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A two character country code from ISO 3166, a blank string
(two space characters) shall indicate that the country is
not defined. Examples: US, FR, DE, ..."
::= { prtLocalizationEntry 3 }
prtLocalizationCharacterSet OBJECT-TYPE
SYNTAX CodedCharSet
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The coded character set used for this localization."
::= { prtLocalizationEntry 4 }
-- The System Resources Tables
-- The Printer MIB makes use of the Host MIB to
-- define system resources by referencing the storage
-- and device groups of the print group. In order to
-- determine, amongst multiple printers serviced by
-- one agent, which printer owns a particular
-- resource, the prtStorageRef and prtDeviceRef tables
-- associate particular storage and device entries to
-- printers.
prtStorageRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtStorageRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { prtGeneral 2 }
prtStorageRefEntry OBJECT-TYPE
SYNTAX PrtStorageRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table will have an entry for each entry in
the host MIB storage table that represents storage associated
with a printer managed by this agent."
INDEX { hrStorageIndex, prtStorageRefSeqNumber }
::= { prtStorageRefTable 1 }
PrtStorageRefEntry ::= SEQUENCE {
prtStorageRefSeqNumber Integer32,
prtStorageRefIndex Integer32
}
prtStorageRefSeqNumber OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This value will be unique amongst all entries with a common
value of hrStorageIndex.
This object allows a storage entry to point to the multiple
printer devices with which it is associated."
::= { prtStorageRefEntry 1 }
prtStorageRefIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the hrDeviceIndex of the printer device that this
storageEntry is associated with."
::= { prtStorageRefEntry 2 }
prtDeviceRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDeviceRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { prtGeneral 3 }
prtDeviceRefEntry OBJECT-TYPE
SYNTAX PrtDeviceRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table will have an entry for each entry in
the host MIB device table that represents a device associated
with a printer managed by this agent."
INDEX { hrDeviceIndex, prtDeviceRefSeqNumber }
::= { prtDeviceRefTable 1 }
PrtDeviceRefEntry ::= SEQUENCE {
prtDeviceRefSeqNumber Integer32,
prtDeviceRefIndex Integer32
}
prtDeviceRefSeqNumber OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This value will be unique amongst all entries with a common
value of hrDeviceIndex.
This object allows a device entry to point to the multiple
printer devices with which it is associated."
::= { prtDeviceRefEntry 1 }
prtDeviceRefIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the hrDeviceIndex of the printer device that this
deviceEntry is associated with."
::= { prtDeviceRefEntry 2 }
-- The Responsible Party group
--
-- This group is optional. However, to claim conformance to this
-- group, it is necessary to implement every object in the group.
prtGeneralCurrentOperator OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the current human operator responsible for
operating this printer. It is suggested that this string
include information that would enable other humans to reach
the operator, such as a phone number."
::= { prtGeneralEntry 4 }
prtGeneralServicePerson OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the last human responsible for servicing
this printer. It is suggested that this string
include information that would enable other humans to reach
the service person, such as a phone number."
::= { prtGeneralEntry 5 }
-- The Input Group
--
-- Input sub-units are managed as a tabular, indexed collection of
-- possible devices capable of providing media for input to the printing
-- process. Input sub-units typically have a location, a type, an
-- identifier, a set of constraints on possible media sizes and
-- potentially other media characteristics, and may be capable of
-- indicating current status or capacity.
--
-- Implementation of every object in this group is mandatory.
prtInput OBJECT IDENTIFIER ::= { printmib 8 }
prtInputDefaultIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtInputIndex corresponding to the default input
sub-unit: that is, this object selects the default source of
input media."
::= { prtGeneralEntry 6 }
prtInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the devices capable of providing media for input
to the printing process."
::= { prtInput 2 }
prtInputEntry OBJECT-TYPE
SYNTAX PrtInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Attributes of a device capable of providing media for input
to the printing process.
Entries may exist in the table for each device
index who's device type is `printer'."
INDEX { hrDeviceIndex, prtInputIndex }
::= { prtInputTable 1 }
PrtInputEntry ::= SEQUENCE {
prtInputIndex Integer32,
prtInputType INTEGER,
prtInputDimUnit MediaUnit,
prtInputMediaDimFeedDirDeclared Integer32,
prtInputMediaDimXFeedDirDeclared Integer32,
prtInputMediaDimFeedDirChosen Integer32,
prtInputMediaDimXFeedDirChosen Integer32,
prtInputCapacityUnit CapacityUnit,
prtInputMaxCapacity Integer32,
prtInputCurrentLevel Integer32,
prtInputStatus SubUnitStatus,
prtInputMediaName OCTET STRING,
prtInputName OCTET STRING,
prtInputVendorName OCTET STRING,
prtInputModel OCTET STRING,
prtInputVersion OCTET STRING,
prtInputSerialNumber OCTET STRING,
prtInputDescription OCTET STRING,
prtInputSecurity PresentOnOff,
prtInputMediaWeight Integer32,
prtInputMediaType OCTET STRING,
prtInputMediaColor OCTET STRING,
prtInputMediaFormParts Integer32
}
prtInputIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this input
sub-unit. Although these values may change due to a major
reconfiguration of the device (e.g. the addition of new
input sub-units to the printer), values are expected to
remain stable across successive printer power cycles."
::= { prtInputEntry 1 }
prtInputType OBJECT-TYPE
-- This value is a type 2 enumeration
SYNTAX INTEGER {
other(1),
unknown(2),
sheetFeedAutoRemovableTray(3),
sheetFeedAutoNonRemovableTray(4),
sheetFeedManual(5),
continuousRoll(6),
continuousFanFold(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of technology (discriminated primarily according to
feeder mechanism type) employed by the input sub-unit. Note,
the Optional Input Class provides for a descriptor field to
further qualify the other choice."
::= { prtInputEntry 2 }
prtInputDimUnit OBJECT-TYPE
SYNTAX MediaUnit
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measurement for use calculating and relaying
dimensional values for this input sub-unit."
::= { prtInputEntry 3 }
prtInputMediaDimFeedDirDeclared OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object provides the value of the declared dimension, in
the feed direction, of the media that is (or, if empty, was or
will be) in this input sub-unit. The feed direction is the
direction in which the media is fed on this sub-unit. This
dimension is measured in input sub-unit dimensional units
(prtInputDimUnit). If this input sub-unit can reliably sense
this value, the value is sensed by the printer and may not be
changed by management requests. Otherwise, the value may be
changed. The value (-1) means other and specifically means
that this sub-unit places no restriction on this parameter.
The value (-2) indicates unknown."
::= { prtInputEntry 4 }
prtInputMediaDimXFeedDirDeclared OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object provides the value of the declared dimension, in
the cross feed direction, of the media that is (or, if empty,
was or will be) in this input sub-unit. The cross feed
direction is ninety degrees relative to the feed direction
associated with this sub-unit. This dimension is measured in
input sub-unit dimensional units (prtInputDimUnit). If this
input sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed by management
requests. Otherwise, the value may be changed. The value (-1)
means other and specifically means that this sub-unit places
no restriction on this parameter. The value (-2) indicates
unknown."
::= { prtInputEntry 5 }
prtInputMediaDimFeedDirChosen OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The printer will act as if media of the chosen dimension (in
the feed direction) is present in this input source. Note
that this value will be used even if the input tray is empty.
Feed dimension measurements
are taken parallel relative to the feed direction
associated with that sub-unit and are in input sub-unit
dimensional units (DimUnit). If the printer supports the
declared dimension, the granted dimension is the same as
the declared dimension. If not, the granted dimension is
set to the closest dimension that the printer supports
when the declared dimension is set. The value (-1) means
other and specifically indicates that this sub-unit
places no restriction on this parameter. The value (-2)
indicates unknown."
::= { prtInputEntry 6 }
prtInputMediaDimXFeedDirChosen OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The printer will act as if media of the chosen dimension (in
the cross feed direction) is present in this input source.
Note that this value will be used even if the input tray is
empty. The cross feed direction is ninety degrees relative
to the feed direction associated with this sub-unit. This
dimension is measured in input sub-unit dimensional units
(DimUnit). If the printer supports the declared
dimension, the granted dimension is the same as the
declared dimension. If not, the granted dimension is set
to the closest dimension that the printer supports when
the declared dimension is set. The value (-1) means other
and specifically indicates that this sub-unit places no
restriction on this parameter. The value (-2) indicates
unknown."
::= { prtInputEntry 7 }
prtInputCapacityUnit OBJECT-TYPE
SYNTAX CapacityUnit
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measurement for use in calculating and relaying
capacity values for this input sub-unit."
::= { prtInputEntry 8 }
prtInputMaxCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum capacity of the input sub-unit in input
sub-unit capacity units (CapacityUnit). There is no
convention associated with the media itself so this value
reflects claimed capacity. If this input sub-unit can
reliably sense this value, the value is sensed by the
printer and may not be changed by management requests;
otherwise, the value may be written (by a Remote
Contol Panel or a Management Application).
The value (-1) means other and specifically
indicates that the sub-unit places no restrictions
on this parameter. The value (-2) means unknown."
::= { prtInputEntry 9 }
prtInputCurrentLevel OBJECT-TYPE
SYNTAX Integer32 -- in capacity units (CapacityUnit).
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current capacity of the input sub-unit in input
sub-unit capacity units (CapacityUnit). If this input
sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed by
management requests; otherwise, the value may
be written (by a Remote Contol Panel or a
Management Application). The value (-1) means other and
specifically indicates that the sub-unit places no
restrictions on this parameter. The value (-2) means unknown.
The value (-3) means that the printer knows that at least one
unit remains."
::= { prtInputEntry 10 }
prtInputStatus OBJECT-TYPE
SYNTAX SubUnitStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of this input sub-unit."
::= { prtInputEntry 11 }
prtInputMediaName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A description of the media contained in this input sub-unit;
This description is intended for display to a human operator.
This description is not processed by the printer. It is used
to provide information not expressible in terms of the other
media attributes (e.g. prtInputMediaDimFeedDirChosen,
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
prtInputMediaType). An example would be `legal tender bond
paper'."
::= { prtInputEntry 12 }
-- INPUT MEASUREMENT
--
-- _______ | |
-- ^ | |
-- | | | |
-- | |_ _ _ _ _ _ _ _ _ _ _| _________________ |direction
-- | | | ^ v
-- MaxCapacity | | |
-- | | Sheets left in tray | CurrentLevel
-- | | | |
-- v | | v
-- _______ +_____________________+ _______
-- The Extended Input Group
--
-- This group is optional. However, to claim conformance to this
-- group, it is necessary to implement every object in the group.
prtInputName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name assigned to this input sub-unit."
::= { prtInputEntry 13 }
prtInputVendorName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor name of this input sub-unit."
::= { prtInputEntry 14 }
prtInputModel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The model name of this input sub-unit."
::= { prtInputEntry 15 }
prtInputVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of this input sub-unit."
::= { prtInputEntry 16 }
prtInputSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number assigned to this input sub-unit."
::= { prtInputEntry 17 }
prtInputDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A free-form text description of this input
sub-unit in the localization specified by
prtGeneralCurrentLocalization."
::= { prtInputEntry 18 }
prtInputSecurity OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if this input sub-unit has some security
associated with it."
::= { prtInputEntry 19 }
-- The Input Media Group
--
-- The Input Media Group supports identification of media installed
-- or available for use on a printing device. Medium resources are
-- identified by name, and include a collection of characteristic
-- attributes that may further be used for selection and management
-- of them. The Input Media group consists of a set of optional
-- "columns" in the Input Table. In this manner, a minimally
-- conforming implementation may choose to not support reporting
-- of media resources if it cannot do so.
--
-- This group is optional. However, to claim conformance to this
-- group, it is necessary to implement every object in the group.
prtInputMediaWeight OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The weight of the medium associated with this input
sub-unit in grams / per meter squared. The value (-2) means
unknown."
::= { prtInputEntry 20 }
prtInputMediaType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the type of medium associated with this input
sub-unit. This name need not be processed by the printer; it
might simply be displayed to an operator. The standardized
string values from ISO 10175 (DPA) and ISO 10180 (SPDL) are:
stationery Separately cut sheets of an opaque material
transparency Separately cut sheets of a transparent material
envelope Envelopes that can be used for conventional
mailing purposes
envelope-plain Envelopes that are not preprinted and have no
windows
envelope-window Envelopes that have windows for addressing
purposes
continuous-long Continuously connected sheets of an opaque
material connected along the long edge
continuous-short Continuously connected sheets of an opaque
material connected along the short edge
tab-stock Media with tabs
multi-part-form Form medium composed of multiple layers not
pre-attached to one another; each sheet may be
drawn separately from an input source
labels Label stock
multi-layer Form medium composed of multiple layers which
are pre-attached to one another; e.g., for
use with impact printers"
::= { prtInputEntry 21 }
prtInputMediaColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the color of the medium associated with
this input sub-unit using standardized string values
from ISO 10175 (DPA) and ISO 10180 (SPDL) which are:
other
unknown
white
pink
yellow
buff
goldenrod
blue
green
transparent
Implementors may add additional string values. The naming
conventions in ISO 9070 are recommended in order to avoid
potential name clashes."
::= { prtInputEntry 22 }
prtInputMediaFormParts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of parts associated with the medium
associated with this input sub-unit if the medium is a
multi-part form. The value (-1) means other and
specifically indicates that the device places no
restrictions on this parameter. The value (-2) means
unknown."
::= { prtInputEntry 23 }
-- The Output Group
--
-- Output sub-units are managed as a tabular, indexed collection of
-- possible devices capable of receiving media delivered from the
-- printing process. Output sub-units typically have a location,
-- a type, an identifier, a set of constraints on possible media
-- sizes and potentially other characteristics, and may be capable
-- of indicating current status or capacity.
--
-- Implementation of every object in this group is mandatory.
prtOutput OBJECT IDENTIFIER ::= { printmib 9 }
prtOutputDefaultIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtOutputIndex corresponding to the default
output sub-unit; that is, this object selects the default
output destination."
::= { prtGeneralEntry 7 }
prtOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the devices capable of receiving media delivered
from the printing process."
::= { prtOutput 2 }
prtOutputEntry OBJECT-TYPE
SYNTAX PrtOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Attributes of a device capable of receiving media delivered
from the printing process.
Entries may exist in the table for each device
index who's device type is `printer'."
INDEX { hrDeviceIndex, prtOutputIndex }
::= { prtOutputTable 1 }
PrtOutputEntry ::= SEQUENCE {
prtOutputIndex Integer32,
prtOutputType INTEGER,
prtOutputCapacityUnit CapacityUnit,
prtOutputMaxCapacity Integer32,
prtOutputRemainingCapacity Integer32,
prtOutputStatus SubUnitStatus,
prtOutputName OCTET STRING,
prtOutputVendorName OCTET STRING,
prtOutputModel OCTET STRING,
prtOutputVersion OCTET STRING,
prtOutputSerialNumber OCTET STRING,
prtOutputDescription OCTET STRING,
prtOutputSecurity PresentOnOff,
prtOutputDimUnit MediaUnit,
prtOutputMaxDimFeedDir Integer32,
prtOutputMaxDimXFeedDir Integer32,
prtOutputMinDimFeedDir Integer32,
prtOutputMinDimXFeedDir Integer32,
prtOutputStackingOrder INTEGER,
prtOutputPageDeliveryOrientation INTEGER,
prtOutputBursting PresentOnOff,
prtOutputDecollating PresentOnOff,
prtOutputPageCollated PresentOnOff,
prtOutputOffsetStacking PresentOnOff
}
prtOutputIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by this printer to identify this
output sub-unit. Although these values may change due
to a major reconfiguration of the sub-unit (e.g. the
addition of new output devices to the printer), values
are expected to remain stable across successive printer
power cycles."
::= { prtOutputEntry 1 }
prtOutputType OBJECT-TYPE
-- This value is a type 2 enumeration
SYNTAX INTEGER {
other(1),
unknown(2),
removableBin(3),
unRemovableBin(4),
continuousRollDevice(5),
mailBox(6),
continuousFanFold(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of technology supported by this output sub-unit."
::= { prtOutputEntry 2 }
prtOutputCapacityUnit OBJECT-TYPE
SYNTAX CapacityUnit
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measurement for use in calculating and relaying
capacity values for this output sub-unit."
::= { prtOutputEntry 3 }
prtOutputMaxCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum capacity of this output sub-unit in output
sub-unit capacity units (CapacityUnit). There is no
convention associated with the media itself so this value
essentially reflects claimed capacity. If this output
sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed by management
requests; otherwise, the value may be written
(by a Remote Contol Panel or a Management Application).
The value (-1) means other and specifically indicates
that the sub-unit places no restrictions on this parameter.
The value (-2) means unknown."
::= { prtOutputEntry 4 }
prtOutputRemainingCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The remaining capacity of the possible output sub-unit
capacity in output sub-unit capacity units (CapacityUnit)
of this output sub-unit. If this output sub-unit can
reliably sense this value, the value is sensed by the
printer and may not be modified by management requests;
otherwise, the value may be written (by
a Remote Contol Panel or a Management
Application). The value (-1) means other and
specifically indicates that the sub-unit places no
restrictions on this parameter. The value (-2) means
unknown. The value (-3) means that the printer knows that
there remains capacity for at least one unit."
::= { prtOutputEntry 5 }
prtOutputStatus OBJECT-TYPE
SYNTAX SubUnitStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of this output sub-unit."
::= { prtOutputEntry 6 }
-- OUTPUT MEASUREMENT
--
-- _______ | | _______
-- ^ | | ^
-- | | | |
-- | | | RemainingCapacity
-- MaxCapacity | | |
-- | | | v ^
-- | |_ _ _ _ _ _ _ _ _ _ _| ___________________ |direction
-- | | | |
-- | | Sheets in output |
-- v | |
-- _______ +_____________________+
-- The Extended Output Group
--
-- This group is optional. However, to claim conformance to this
-- group, it is necessary to implement every object in the group.
prtOutputName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name assigned to this output sub-unit."
::= { prtOutputEntry 7 }
prtOutputVendorName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor name of this output sub-unit."
::= { prtOutputEntry 8 }
prtOutputModel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name assigned to this output sub-unit."
::= { prtOutputEntry 9 }
prtOutputVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of this output sub-unit."
::= { prtOutputEntry 10 }
prtOutputSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number assigned to this output sub-unit."
::= { prtOutputEntry 11 }
prtOutputDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" A free-form text description of this output sub-unit in the
localization specified by prtGeneralCurrentLocalization."
::= { prtOutputEntry 12 }
prtOutputSecurity OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if this output sub-unit has some security associated
with it and if that security is enabled or not."
::= { prtOutputEntry 13 }
-- The Output Dimensions Group
--
-- This group is optional. However, to claim conformance to this
-- group, it is necessary to implement every object in the group.
prtOutputDimUnit OBJECT-TYPE
SYNTAX MediaUnit
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measurement for use in calculating and relaying
dimensional values for this output sub-unit."
::= { prtOutputEntry 14 }
prtOutputMaxDimFeedDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum dimensions supported by this output sub-unit
for measurements taken parallel relative to the feed
direction associated with that sub-unit in output
sub-unit dimensional units (DimUnit). If this output
sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed with
management protocol operations."
::= { prtOutputEntry 15 }
prtOutputMaxDimXFeedDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum dimensions supported by this output sub-unit
for measurements taken ninety degrees relative to the
feed direction associated with that sub-unit in output
sub-unit dimensional units (DimUnit). If this output
sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed with
management protocol operations."
::= { prtOutputEntry 16 }
prtOutputMinDimFeedDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum dimensions supported by this output sub-unit
for measurements taken parallel relative to the feed
direction associated with that sub-unit in output
sub-unit dimensional units (DimUnit). If this output
sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed with
management protocol operations."
::= { prtOutputEntry 17 }
prtOutputMinDimXFeedDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum dimensions supported by this output sub-unit
for measurements taken ninety degrees relative to the
feed direction associated with that sub-unit in output
sub-unit dimensional units (DimUnit). If this output
sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed with
management protocol operations."
::= { prtOutputEntry 18 }
-- The Output Features Group
--
-- This group is optional. However, to claim conformance to this
-- group, it is necessary to implement every object in the group.
prtOutputStackingOrder OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
unknown(2),
firstToLast(3),
lastToFirst(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current state of the stacking order for the
associated output sub-unit. `FirstToLast' means
that as pages are output the front of the next page is
placed against the back of the previous page.
`LasttoFirst' means that as pages are output the back
of the next page is placed against the front of the
previous page."
::= { prtOutputEntry 19 }
prtOutputPageDeliveryOrientation OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
faceUp(3),
faceDown(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The reading surface that will be `up' when pages are
delivered to the associated output sub-unit. Values are
Face-Up and Face-Down. (Note: interpretation of these
values is in general context-dependent based on locale;
presentation of these values to an end-user should be
normalized to the expectations of the user)."
::= { prtOutputEntry 20 }
prtOutputBursting OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates that the outputing sub-unit
supports bursting, and if so, whether the feature is enabled.
Bursting is the process by which continuous media is separated
into individual sheets, typically by bursting along pre-formed
perforations."
::= { prtOutputEntry 21 }
prtOutputDecollating OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates that the output supports
supports decollating, and if so, whether the feature
is enabled. Decollating is the process by which the
individual parts within a multi-part form are separated
and sorted into separate stacks for each part."
::= { prtOutputEntry 22 }
prtOutputPageCollated OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates that the output sub-unit
supports page collation, and if so, whether the feature is
enabled."
::= { prtOutputEntry 23 }
prtOutputOffsetStacking OBJECT-TYPE
SYNTAX PresentOnOff
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates that the output supports
supports offset stacking, and if so, whether the feature is
enabled."
::= { prtOutputEntry 24 }
-- The Marker Group
--
-- A marker is the mechanism that produces marks on the print media. The
-- marker sub-units and their associated supplies are represented by the
-- Marker Group in the model. A printer can contain one or more marking
-- mechanisms. Some examples of multiple marker sub-units are: a printer
-- with separate markers for normal and magnetic ink or an imagesetter
-- that can output to both a proofing device and final film. Each marking
-- device can have its own set of characteristics associated with it,
-- such as marking technology and resolution.
--
-- Implementation of every object in this group is mandatory.
prtMarker OBJECT IDENTIFIER ::= { printmib 10 }
prtMarkerDefaultIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtMarkerIndex corresponding to the
default markersub-unit; that is, this object selects the
default marker."
::= { prtGeneralEntry 8 }
-- The printable area margins as listed below define an area of the print
-- media which is guaranteed to be printable for all combinations of
-- input, media paths, and interpreters for this marker.
prtMarkerTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMarkerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { prtMarker 2 }
prtMarkerEntry OBJECT-TYPE
SYNTAX PrtMarkerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries may exist in the table for each device
index who's device type is `printer'."
INDEX { hrDeviceIndex, prtMarkerIndex }
::= { prtMarkerTable 1 }
PrtMarkerEntry ::= SEQUENCE {
prtMarkerIndex Integer32,
prtMarkerMarkTech INTEGER,
prtMarkerCounterUnit INTEGER,
prtMarkerLifeCount Counter32,
prtMarkerPowerOnCount Counter32,
prtMarkerProcessColorants Integer32,
prtMarkerSpotColorants Integer32,
prtMarkerAddressabilityUnit INTEGER,
prtMarkerAddressabilityFeedDir Integer32,
prtMarkerAddressabilityXFeedDir Integer32,
prtMarkerNorthMargin Integer32,
prtMarkerSouthMargin Integer32,
prtMarkerWestMargin Integer32,
prtMarkerEastMargin Integer32,
prtMarkerStatus SubUnitStatus
}
prtMarkerIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this marking
SubUnitStatus. Although these values may change due to a major
reconfiguration of the device (e.g. the addition of new marking
sub-units to the printer), values are expected to remain
stable across successive printer power cycles."
::= { prtMarkerEntry 1 }
prtMarkerMarkTech OBJECT-TYPE
-- This value is a type 2 enumeration
SYNTAX INTEGER {
other(1),
unknown(2),
electrophotographicLED(3),
electrophotographicLaser(4),
electrophotographicOther(5),
impactMovingHeadDotMatrix9pin(6),
impactMovingHeadDotMatrix24pin(7),
impactMovingHeadDotMatrixOther(8),
impactMovingHeadFullyFormed(9),
impactBand(10),
impactOther(11),
inkjetAqueous(12),
inkjetSolid(13),
inkjetOther(14),
pen(15),
thermalTransfer(16),
thermalSensitive(17),
thermalDiffusion(18),
thermalOther(19),
electroerosion(20),
electrostatic(21),
photographicMicrofiche(22),
photographicImagesetter(23),
photographicOther(24),
ionDeposition(25),
eBeam(26),
typesetter(27)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of marking technology used for this marking sub-unit."
::= { prtMarkerEntry 2 }
prtMarkerCounterUnit OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
tenThousandthsOfInches(3), -- .0001
micrometers(4),
characters(5),
lines(6),
impressions(7),
sheets(8),
dotRow(9),
hours(11),
feet(16),
meters(17)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit that will be used by the printer when reporting
counter values for this marking sub-unit. The
time units of measure are provided for a device like a
strip recorder that does not or cannot track the physical
dimensions of the media and does not use characters,
lines or sheets."
::= { prtMarkerEntry 3}
prtMarkerLifeCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of the number of units of measure counted during
the life of printer using units of measure as specified by
CounterUnit."
::= { prtMarkerEntry 4 }
prtMarkerPowerOnCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of the number of units of measure counted since the
equipment was most recently powered on using units of measure as
specified by CounterUnit."
::= { prtMarkerEntry 5 }
prtMarkerProcessColorants OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of process colors supported by this marker. A
process color of 1 implies monochrome. The value of this
object and SpotColorants cannot both be 0. Must be 0 or
greater."
::= { prtMarkerEntry 6 }
prtMarkerSpotColorants OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of spot colors supported by this marker. The
value of this object and ProcessColorants cannot
both be 0. Must be 0 or greater."
::= { prtMarkerEntry 7 }
prtMarkerAddressabilityUnit OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
tenThousandthsOfInches(3), -- .0001
micrometers(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measure of distances."
::= { prtMarkerEntry 8 }
prtMarkerAddressabilityFeedDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of addressable marking positions in the feed
direction per 10000 units of measure specified by
AddressabilityUnit. A value of (-1) implies 'other' or
'infinite' while a value of (-2) implies 'unknown'."
::= { prtMarkerEntry 9 }
prtMarkerAddressabilityXFeedDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of addressable marking positions in the cross
feed direction in 10000 units of measure specified by
AddressabilityUnit. A value of (-1) implies 'other' or
'infinite' while a value of (-2) implies 'unknown'."
::= { prtMarkerEntry 10 }
prtMarkerNorthMargin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The margin, in units identified by AddressabilityUnit,
from the leading edge of the medium as the medium flows
throught the marking engine with the side to be imaged
facing the observer. The leading edge is the North edge
and the other edges are defined by the normal compass
layout of directions with the compass facing the
observer. Printing within the area bounded by all four
margins is guaranteed for all interpreters. The value
(-2) means unknown."
::= { prtMarkerEntry 11 }
prtMarkerSouthMargin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The margin from the South edge (see NorthMargin)
of the medium in units identified by
AddressabilityUnit. Printing within the area bounded by
all four margins is guaranteed for all interpreters.
The value (-2) means unknown."
::= { prtMarkerEntry 12 }
prtMarkerWestMargin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The margin from the West edge (see NorthMargin) of the
medium in units identified by AddressabilityUnit.
Printing within the area bouned by all four margins is
guaranteed for all interpreters. The value (-2) means
unknown."
::= { prtMarkerEntry 13 }
prtMarkerEastMargin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The margin from the East edge (see NorthMargin) of the
medium in units identified by AddressabilityUnit.
Printing within the area bounded by all four margins is
guaranteed for all interpreters. The value (-2) means
unknown."
::= { prtMarkerEntry 14 }
prtMarkerStatus OBJECT-TYPE
SYNTAX SubUnitStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of this marker sub-unit."
::= { prtMarkerEntry 15 }
prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }
prtMarkerSuppliesTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMarkerSuppliesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of the marker supplies available on this printer."
::= { prtMarkerSupplies 1 }
prtMarkerSuppliesEntry OBJECT-TYPE
SYNTAX PrtMarkerSuppliesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Attributes of a marker supply.
Entries may exist in the table for each device
index who's device type is `printer'."
INDEX { hrDeviceIndex, prtMarkerSuppliesIndex }
::= { prtMarkerSuppliesTable 1 }
PrtMarkerSuppliesEntry ::= SEQUENCE {
prtMarkerSuppliesIndex Integer32,
prtMarkerSuppliesMarkerIndex Integer32,
prtMarkerSuppliesColorantIndex Integer32,
prtMarkerSuppliesClass INTEGER,
prtMarkerSuppliesType INTEGER,
prtMarkerSuppliesDescription OCTET STRING,
prtMarkerSuppliesSupplyUnit INTEGER,
prtMarkerSuppliesMaxCapacity Integer32,
prtMarkerSuppliesLevel Integer32
}
prtMarkerSuppliesIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this marker
supply. Although these values may change due to a major
reconfiguration of the device (e.g. the addition of new marker
supplies to the printer), values are expected to remain stable
across successive printer power cycles."
::= { prtMarkerSuppliesEntry 1 }
prtMarkerSuppliesMarkerIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of prtMarkerIndex corresponding to the
marking sub-unit with which this marker supply
sub-unit is associated."
::= { prtMarkerSuppliesEntry 2 }
prtMarkerSuppliesColorantIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of prtMarkerColorantIndex
corresponding to the colorant with which this
marker supply sub-unit is associated. This value
shall be 0 if there is no colorant table."
::= { prtMarkerSuppliesEntry 3 }
prtMarkerSuppliesClass OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
other(1),
supplyThatIsConsumed(3),
receptacleThatIsFilled(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether this supply entity represents a supply
container that is consumed or a receptacle that is filled."
::= { prtMarkerSuppliesEntry 4 }
prtMarkerSuppliesType OBJECT-TYPE
-- This value is a type 3 enumeration
SYNTAX INTEGER {
other(1),
unknown(2),
toner(3),
wasteToner(4),
ink(5),
inkCartridge(6),
inkRibbon(7),
wasteInk(8),
opc(9),
developer(10),
fuserOil(11),
solidWax(12),
ribbonWax(13),
wasteWax(14)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of this supply."
::= { prtMarkerSuppliesEntry 5 }
prtMarkerSuppliesDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of this supply container/receptacle in the
localization specified by prtGeneralCurrentLocalization."
::= { prtMarkerSuppliesEntry 6 }
prtMarkerSuppliesSupplyUnit OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
tenThousandthsOfInches(3), -- .0001
micrometers(4),
thousandthsOfOunces(12),
tenthsOfGrams(13),
hundrethsOfFluidOunces(14),
tenthsOfMilliliters(15)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit of this marker supply container/receptacle."
::= { prtMarkerSuppliesEntry 7 }
prtMarkerSuppliesMaxCapacity OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum capacity of this supply container/receptacle
expressed in SupplyUnit. If this supply
container/receptacle can reliably sense this value, the
value is sensed by the printer and is read-only;
otherwise, the value may be written (by a Remote Contol
Panel or a Management Application). The value (-1) means
other and specifically indicates that the sub-unit places
no restrictions on this parameter. The value (-2) means
unknown."
::= { prtMarkerSuppliesEntry 8 }
prtMarkerSuppliesLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current level if this supply is a container; the
remaining space if this supply is a receptacle. If this
supply container/receptacle can reliably sense this
value, the value is sensed by the printer and is
read-only; otherwise, the value may be written (by a
Remote Contol Panel or a Management Application). The
value (-1) means other and specifically indicates that
the sub-unit places no restrictions on this parameter.
The value (-2) means unknown. A value of (-3) means that the
printer knows that there is some supply/remaining space,
respectively."
::= { prtMarkerSuppliesEntry 9 }
-- The Marker Colorant Group
--
-- This group is optional. However, to claim conformance to this
-- group, it is necessary to implement every object in the group.
prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 }
prtMarkerColorantTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMarkerColorantEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of all of the colorants available on the printer."
::= { prtMarkerColorant 1 }
prtMarkerColorantEntry OBJECT-TYPE
SYNTAX PrtMarkerColorantEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Attributes of a colorant available on the printer.
Entries may exist in the table for each device
index who's device type is `printer'."
INDEX { hrDeviceIndex, prtMarkerColorantIndex }
::= { prtMarkerColorantTable 1 }
PrtMarkerColorantEntry ::= SEQUENCE {
prtMarkerColorantIndex Integer32,
prtMarkerColorantMarkerIndex Integer32,
prtMarkerColorantRole INTEGER,
prtMarkerColorantValue OCTET STRING,
prtMarkerColorantTonality Integer32
}
prtMarkerColorantIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this colorant.
Although these values may change due to a major
reconfiguration of the device (e.g. the addition of new
colorants to the printer), values are expected to remain
stable across successive printer power cycles."
::= { prtMarkerColorantEntry 1 }
prtMarkerColorantMarkerIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of prtMarkerIndex corresponding to the
marker sub-unit with which this colorant entry is
associated."
::= { prtMarkerColorantEntry 2 }
prtMarkerColorantRole OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER { -- Colorant Role
other(1),
process(3),
spot(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The role played by this colorant."
::= { prtMarkerColorantEntry 3 }
prtMarkerColorantValue OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the color of this The name of the color of this
colorant using standardized string names from ISO 10175 (DPA)
and ISO 10180 (SPDL) which are:
other
unknown
white
red
green
blue
cyan
magenta
yellow
black
Implementors may add additional string values. The naming
conventions in ISO 9070 are recommended in order to avoid
potential name clashes"
::= { prtMarkerColorantEntry 4 }
prtMarkerColorantTonality OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The distinct levels of tonality realizable by a marking
sub-unit when using this colorant. This value does not
include the number of levels of tonal difference that an
interpreter can obtain by techniques such as half toning.
This value must be at least 2."
::= { prtMarkerColorantEntry 5 }
-- The Media Path Group
--
-- The media paths encompass the mechanisms in the printer that move the
-- media through the printer and connect all other media related sub-
-- units: inputs, outputs, markers and finishers. A printer contains one
-- or more media paths. These are represented by the Media Path Group in
-- the model. The Media Path group has some attributes that apply to all
-- paths plus a table of the separate media paths.
prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }
prtMediaPathDefaultIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtMediaPathIndex corresponding to
the default media path; that is, the selection of the
default media path."
::= { prtGeneralEntry 9 }
prtMediaPathTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMediaPathEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { prtMediaPath 4 }
prtMediaPathEntry OBJECT-TYPE
SYNTAX PrtMediaPathEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries may exist in the table for each device
index who's device type is `printer'."
INDEX { hrDeviceIndex, prtMediaPathIndex }
::= { prtMediaPathTable 1 }
PrtMediaPathEntry ::= SEQUENCE {
prtMediaPathIndex Integer32,
prtMediaPathMaxSpeedPrintUnit INTEGER,
prtMediaPathMediaSizeUnit MediaUnit,
prtMediaPathMaxSpeed Integer32,
prtMediaPathMaxMediaFeedDir Integer32,
prtMediaPathMaxMediaXFeedDir Integer32,
prtMediaPathMinMediaFeedDir Integer32,
prtMediaPathMinMediaXFeedDir Integer32,
prtMediaPathType INTEGER,
prtMediaPathDescription OCTET STRING,
prtMediaPathStatus SubUnitStatus
}
prtMediaPathIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this media
path. Although these values may change due to a major
reconfiguration of the device (e.g. the addition of new
media paths to the printer), values are expected to remain
stable across successive printer power
cycles."
::= { prtMediaPathEntry 1 }
prtMediaPathMaxSpeedPrintUnit OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
tenThousandthsOfInchesPerHour(3), -- .0001/hour
micrometersPerHour(4),
charactersPerHour(5),
linesPerHour(6),
impressionsPerHour(7),
sheetsPerHour(8),
dotRowPerHour(9),
feetPerHour(16),
metersPerHour(17)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The unit of measure used in specifying the speed of all media
paths in the printer."
::= { prtMediaPathEntry 2 }
prtMediaPathMediaSizeUnit OBJECT-TYPE
SYNTAX MediaUnit
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The units of measure of media size for use in calculating and
relaying dimensional values for all media paths in the printer."
::= { prtMediaPathEntry 3 }
prtMediaPathMaxSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum printing speed of this media path expressed in
prtMediaPathMaxSpeedUnit's. A value of (-1) implies
'other'."
::= { prtMediaPathEntry 4 }
prtMediaPathMaxMediaFeedDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum physical media size in the feed direction of this
media path expressed in units of measure specified by
MediaSizeUnit. A value of (-1) implies 'unlimited'. A value
of (-2) implies 'unknown'"
::= { prtMediaPathEntry 5 }
prtMediaPathMaxMediaXFeedDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum physical media size across the feed direction of
this media path expressed in units of measure specified by
MediaSizeUnit. A value of (-2) implies 'unknown'."
::= { prtMediaPathEntry 6 }
prtMediaPathMinMediaFeedDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum physical media size in the feed direction of this
media path expressed in units of measure specified by
MediaSizeUnit. A value of (-2) implies 'unknown'."
::= { prtMediaPathEntry 7 }
prtMediaPathMinMediaXFeedDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum physical media size across the feed direction of
this media path expressed in units of measure specified by
MediaSizeUnit. A value of (-2) implies 'unknown'."
::= { prtMediaPathEntry 8 }
prtMediaPathType OBJECT-TYPE
-- This value is a type 2 enumeration
SYNTAX INTEGER {
other(1),
unknown(2),
longEdgeBindingDuplex(3),
shortEdgeBindingDuplex(4),
simplex(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the media path for this media path."
::= { prtMediaPathEntry 9 }
prtMediaPathDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The manufacturer-provided description of this media path in
the localization specified by prtGeneralCurrentLocalization."
::= { prtMediaPathEntry 10 }
prtMediaPathStatus OBJECT-TYPE
SYNTAX SubUnitStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of this media path."
::= { prtMediaPathEntry 11 }
-- The Channel Group
--
-- Implementation of every object in this group is mandatory.
-- Channels are independent sources of print data. Here,
-- print data is the term used for the information that is
-- used to construct printed pages and may have both data
-- and control aspects. The output of a channel is in a form
-- suitable for input to one of the interpreters as a
-- stream. A channel may be independently enabled (allowing
-- print data to flow) or disabled (stopping the flow of
-- print data). A printer may have one or more channels.
--
-- Basically, the channel abstraction is intended to cover
-- all the aspects of getting the print data to an
-- interpreter. This might include transporting the data
-- from one place to another, it might include (invisible)
-- compression, it might include encoding or packetizing to
-- provide multiple information sources over a single
-- physical interface and it might include filtering
-- characters that were destined for another kind of
-- channel. All of these aspects are hidden in the channel
-- abstraction.(Note some Page Description Languages have
-- compression built into them so "invisible" compression
-- refers to compression done by the transport medium and
-- removed before the data is presented to the interpreter.)
--
-- There are many kinds of channels;some of which are based
-- on networks and others which are not. For example, a
-- channel can be a serial (or parallel) connection; it can
-- be a service, such as the Unix Line Printer Daemon (LPD),
-- offering itself over a network connection (interface); or
-- it could be a disk drive into which a floppy disks with
-- the print data is inserted. Each channel is typically
-- identified by the electronic path and/or service protocol
-- used to deliver print data to the printer.
--
-- Channel example Implementation
--
-- serial port channel bi-directional data channel
-- parallel port channel often uni-directional channel
-- IEEE 1284 port channel bi-directional channel
-- SCSI port channel bi-directional
-- Apple PAP channel may be based on Local-, Ether-or
-- TokenTalk
-- LPD Server channel typically TCP/IP based, port 515
-- Novell Remote Printer typically SPX/IPX based channel
-- Novell Print Server typically SPX/IPX based channel
-- port 9100 channel HP and friends
-- Adobe AppSocket(9101) channel a bi-directional extension of LPD
--
-- It is easy to note that this is a mixed bag. There are
-- some physical connections over which no (or very meager)
-- protocols are run (e.g. the serial or old parallel ports)
-- and there are services which often have elaborate
-- protocols that run over a number of protocol stacks. In
-- the end what is important is the delivery of print data
-- thru the channel.
--
-- The channel sub-units are represented by the Channel
-- Group in the Model. It has a current Control Language
-- which can be used to specify which interpreter is to be
-- used for the print data and to query and change
-- environment variables used by the interpreters (and
-- Mangement Applications). There is also a default
-- interpreter that is to be used if an interpreter is not
-- explicitly specified using the Control Language. Channel
-- sub-units are based on an underlying interface.
-- The channel table and its underlying structure
--
-- The first seven items in the Channel Table define the
-- "channel" itself. A channel typically depends on other
-- protocols and interfaces to provide the data that flows
-- thru the channel. It is necessary to provide control of
-- the (perhaps complex) process by which print data arrives
-- at an interpreter. Control is largely limited to enabling
-- or disabling the whole channel. It is likely, however,
-- that more control of the process of accessing print data
-- will be needed over time. Thus, the ChannelType will
-- allow type specific data to be associated with each
-- channel (using ChannelType specific groups in a fashion
-- analogous to the media specific MIBs that are associated
-- with the IANAIfType in the Interfaces Table). As a first
-- step in this direction, each channel will identify the
-- underlying Interface on which it is based. This is the
-- eighth object in each row of the table.
-- Some examples of the kind of control are where
-- compression or encoding is used; and whether the data is
-- filtered to remove file storage anomolies such as those
-- created by using MS-DOS/PC-DOS LPT1:.
--
-- The Channel Table
--
-- The prtChannelTable represents the set of input data sources which
-- can provide print data to one or more of the interpreters
-- available on a printer
prtChannel OBJECT IDENTIFIER ::= { printmib 14 }
prtChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { prtChannel 1 }
prtChannelEntry OBJECT-TYPE
SYNTAX PrtChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries may exist in the table for each device
index who's device type is `printer'."
INDEX { hrDeviceIndex, prtChannelIndex }
::= { prtChannelTable 1 }
PrtChannelEntry ::= SEQUENCE {
prtChannelIndex Integer32,
prtChannelType INTEGER,
prtChannelProtocolVersion OCTET STRING,
prtChannelCurrentJobCntlLangIndex Integer32,
prtChannelDefaultPageDescLangIndex Integer32,
prtChannelState INTEGER,
prtChannelIfIndex Integer32,
prtChannelStatus SubUnitStatus
}
prtChannelIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this data
channel. Although these values may change due to a major
reconfiguration of the device (e.g. the addition of new data
channels to the printer), values are expected to remain
stable across successive printer power cycles."
::= { prtChannelEntry 1 }
prtChannelType OBJECT-TYPE
-- This value is a type 2 enumeration
SYNTAX INTEGER {
other(1),
chSerialPort(3),
chParallelPort(4),
chIEEE1284Port(5),
chSCSIPort(6),
chAppleTalkPAP(7), -- AppleTalk Printer Achess Protocol
chLPDServer(8),
chNetwareRPrinter(9), -- Netware
chNetwarePServer(10), -- Netware
chPort9100(11),
chAppSocket(12), -- a bi-directional, LPD-like
-- protocol using 9101 for
-- control and 9100 for data.
-- Adobe Systems, Inc.
chFTP(13), -- FTP "PUT" to printer
chTFTP(14),
chDLCLLCPort(15),
chIBM3270(16),
chIBM5250(17),
chFax(18),
chIEEE1394(19),
chTransport1(20), -- port 35
chCPAP(21), -- port 170
chDCERemoteProcCall(22), -- OSF
chONCRemoteProcCall(23), -- Sun Microsystems
chOLE(24), -- Microsoft
chNamedPipe(25),
chPCPrint(26), -- Banyan
chServerMessageBlock(27),
-- File/Print sharing protocol used by
-- various network operating systems
-- from IBM 3Com, Microsoft and others
chDPMF(28), -- Distributed Print Mgt. Framework, IBM
chDLLAPI(29), -- Microsoft
chVxDAPI(30), -- Microsoft
chSystemObjectManager(31), -- IBM
chDECLAT(32), -- Digital Equipment Corp.
chNPAP(33)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of this print data channel. This
object provides the linkage to ChannelType-specific
groups that may (conceptually) extend the prtChannelTable
with additional details about that channel."
::= { prtChannelEntry 2 }
prtChannelProtocolVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the protocol used on this
channel. The format used for version numbering depends
on prtChannelType."
::= { prtChannelEntry 3 }
prtChannelCurrentJobCntlLangIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtInterpreterIndex corresponding to the
Control Language Interpreter for this channel. This
interpreter defines the syntax used for control
functions, such as querying or changing environment
variables and identifying job boundaries (e.g. PJL,
PostScript, NPAP). Must be 1 or greater."
::= { prtChannelEntry 4 }
prtChannelDefaultPageDescLangIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of prtInterpreterIndex corresponding to the
Page Description Language Interpreter for this channel.
This interpreter defines the default Page Description
Language interpreter to be used for the print data unless
the Control Language is used to select a specific
interpreter (e.g., PCL, PostScript Language,
auto-sense). Must be 1 or greater."
::= { prtChannelEntry 5 }
prtChannelState OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
other(1),
printDataAccepted(3),
noDataAccepted(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The state of this print data channel. The value determines
whether control information and print data is allowed through
this channel or not."
::= { prtChannelEntry 6 }
prtChannelIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of ifIndex (in the ifTable; see the interface
section of MIB-2/RFC 1213) which corresponds to this channel.
When more than one row of the ifTable is relevant, this is
the index of the row representing the topmost layer in the
interface hierarchy. A value of zero indicates that no
interface is associated with this channel."
::= { prtChannelEntry 7 }
prtChannelStatus OBJECT-TYPE
SYNTAX SubUnitStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the channel."
::= { prtChannelEntry 8 }
-- The Interpreter Group
--
-- The interpreter sub-units are responsible for the conversion of a
-- description of intended print instances into images that are to be
-- marked on the media. A printer may have one or more interpreters. The
-- interpreter sub-units are represented by the Interpreter Group in the
-- Model. Each interpreter is generally implemented with software running
-- on the System Controller sub-unit. The Interpreter Table has one entry
-- per interpreter where the interpreters include both Page Description
-- Language (PDL) Interpreters and Control Language Interpreters.
--
-- Implementation of every object in this group is mandatory.
prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 }
-- Interpreter Table
--
-- The prtInterpreterTable is a table representing the interpreters in
-- the printer. An entry shall be placed in the interpreter table for
-- each interpreter on the printer.
prtInterpreterTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInterpreterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { prtInterpreter 1 }
prtInterpreterEntry OBJECT-TYPE
SYNTAX PrtInterpreterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries may exist in the table for each device
index who's device type is `printer'."
INDEX { hrDeviceIndex, prtInterpreterIndex }
::= { prtInterpreterTable 1 }
PrtInterpreterEntry ::= SEQUENCE {
prtInterpreterIndex Integer32,
prtInterpreterLangFamily INTEGER,
prtInterpreterLangLevel OCTET STRING,
prtInterpreterLangVersion OCTET STRING,
prtInterpreterDescription OCTET STRING,
prtInterpreterVersion OCTET STRING,
prtInterpreterDefaultOrientation INTEGER,
prtInterpreterFeedAddressability Integer32,
prtInterpreterXFeedAddressability Integer32,
prtInterpreterDefaultCharSetIn CodedCharSet,
prtInterpreterDefaultCharSetOut CodedCharSet,
prtInterpreterTwoWay INTEGER
}
prtInterpreterIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each PDL or control language for which
there exists an interpreter or emulator in the printer. The
value is used to identify this interpreter. Although these
values may change due to a major reconfiguration of the device
(e.g. the addition of new interpreters to the printer), values
are expected to remain stable across successive printer power
cycles."
::= { prtInterpreterEntry 1 }
prtInterpreterLangFamily OBJECT-TYPE
-- This value is a type 2 enumeration
SYNTAX INTEGER {
other(1),
langPCL(3), -- PCL. Starting with PCL version 5,
-- HP-GL/2 is included as part of the
-- PCL language.
-- PCL and HP-GL/2 are registered
-- trademarks of Hewlett-Packard Company.
langHPGL(4), -- Hewlett-Packard Graphics Language.
-- HP-GL is a registered trademark of
-- Hewlett-Packard Company.
langPJL(5), -- Peripheral Job Language. Appears in the
-- data stream between data intended for a
-- page description language.
-- Hewlett-Packard Co.
langPS(6), -- PostScript Language (tm)
-- Postscript - a trademark of Adobe
-- Systems Incorporated which may be
-- registered in certain jurisdictions
langPSPrinter(42), -- The PostScript Language used for
-- control (with any PDLs)
-- Adobe Systems Incorporated
langIPDS(7), -- Intelligent Printer Data Stream
-- Bi-directional print data stream for
-- documents consisting of data objects
-- (text, image, graphics, bar codes),
-- resources (fonts, overlays) and page,
-- form and finishing instructions.
-- Facilitates system level device
-- control, document tracking and error
-- recovery throughout the print process.
-- Pennant Systems, IBM
langPPDS(8), -- IBM Personal Printer Data Stream.
-- Originally called IBM ASCII, the name
-- was changed to PPDS when the Laser
-- Printer was introduced in 1989.
-- Lexmark International, Inc.
langEscapeP(9),
langEpson(10),
langDDIF(11), -- Digital Document Interchange Format
-- Digital Equipment Corp., Maynard MA
langInterpress(12),
langISO6429(13), -- ISO 6429. Control functions for Coded
-- Character Sets (has ASCII control
-- characters, plus additional controls for
-- character imaging devices.)
-- ISO Standard, Geneva, Switzerland
langLineData(14), -- line-data: Lines of data as separate
-- ASCII or EBCDIC records and containing
-- no control functions (no CR, LF, HT, FF,
-- etc.). For use with traditional line
-- printers. May use CR and/or LF to
-- delimit lines, instead of records. See
-- ISO 10175 Document Printing Application
-- (DPA)
-- ISO standard, Geneva, Switzerland
langMODCA(15), -- Mixed Object Document Content Architecture
-- Definitions that allow the composition,
-- interchange, and presentation of final
-- form documents as a collection of data
-- objects (text, image, graphics, bar
-- codes), resources (fonts, overlays) and
-- page, form and finishing instructions.
-- Pennant Systems, IBM
langREGIS(16), -- Remote Graphics Instruction Set,
-- Digital Equipment Corp., Maynard MA
langSCS(17), -- SNA Character String
-- Bi-directional print data stream for SNA
-- LU-1 mode of communications
-- IBM
langSPDL(18), -- ISO 10180 Standard Page Description
-- Language
-- ISO Standard
langTEK4014(19),
langPDS(20),
langIGP(21),
langCodeV(22), -- Magnum Code-V, Image and printer control
-- language used to control impact/dot-
-- matrix printers.
-- QMS, Inc., Mobile AL
langDSCDSE(23), -- DSC-DSE: Data Stream Compatible and
-- Emulation Bi-directional print data
-- stream for non-SNA (DSC) and SNA LU-3
-- 3270 controller (DSE) communications
-- IBM
langWPS(24), -- Windows Printing System, Resource based
-- command/data stream used by Microsoft At
-- Work Peripherals.
-- Developed by the Microsoft Corporation.
langLN03(25), -- Early DEC-PPL3, Digital Equipment Corp.
langCCITT(26),
langQUIC(27), -- QUIC (Quality Information Code), Page
-- Description Language for laser printers.
-- Included graphics, printer control
-- capability and emulation of other well-
-- known printer .
-- QMS, Inc.
langCPAP(28), -- Common Printer Access Protocol
-- Digital Equipment Corp.
langDecPPL(29), -- Digital ANSI-Compliant Printing Protocol
-- (DEC-PPL)
-- Digital Equipment Corp.
langSimpleText(30),-- simple-text: character coded data,
-- including NUL, CR , LF, HT, and FF
-- control characters. See ISO 10175
-- Document Printing Application (DPA)
-- ISO standard, Geneva, Switzerland
langNPAP(31), -- Network Printer Alliance Protocol
-- IEEE 1284.1
langDOC(32), -- Document Option Commands, Appears in the
-- data stream between data intended for a
-- page description .
-- QMS, Inc.
langimPress(33), -- imPRESS, Page description language
-- originally developed for the ImageServer
-- line of systems. A binary language
-- providing representations for text,
-- simple graphics (rules, lines, conic
-- sections), and some large forms (simple
-- bit-map and CCITT group 3/4 encoded).The
-- language was intended to be sent over an
-- 8-bit channel and supported early
-- document preparation languages (e.g. TeX
-- and TROFF).
-- QMS, Inc.
langPinwriter(34), -- 24 wire dot matrix printer for
-- USA, Europe, and Asia except Japan.
-- More widely used in Germany, and some
-- Asian countries than in US.
-- NEC
langNPDL(35), -- Page printer for Japanese
-- market.
-- NEC
langNEC201PL(36), -- Serial printer language used in the
-- Japanese market.
-- NEC
langAutomatic(37), -- Automatic PDL sensing. Automatic
-- sensing of the interpreter language
-- family by the printer examining the
-- document content. Which actual
-- interpreter language families are sensed
-- depends on the printer implementation.
langPages(38), -- Page printer Advanced Graphic Escape Set
-- IBM Japan
langLIPS(39), -- LBP Image Processing System
langTIFF(40), -- Tagged Image File Format (Aldus)
langDiagnostic(41),-- A hex dump of the input to the
-- interpreter
langCaPSL(43), -- Canon Print Systems Language
langEXCL(44), -- Extended Command Language
-- Talaris Systems Inc.
langLCDS(45), -- Line Conditioned Data Stream
-- Xerox Corporation
langXES(46) -- Xerox Escape Sequences
-- Xerox Corporation
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The family name of a Page Description Language (PDL) or
control language which this interpreter in the printer can
interpret or emulate. This type 2 list of enumerations
requires review before additional entries are made."
::= { prtInterpreterEntry 2 }
prtInterpreterLangLevel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The level of the language which this interpreter is
interpreting or emulating. This might contain a value like
'5e' for an interpreter which is emulating level 5e of the PCL
language. It might contain '2' for an interpreter which is
emulating level 2 of the PostScript language. Similarly it
might contain '2' for an interpreter which is emulating level
2 of the HPGL language."
::= { prtInterpreterEntry 3 }
prtInterpreterLangVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date code or version of the language which this interpreter
is interpreting or emulating."
::= { prtInterpreterEntry 4 }
prtInterpreterDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A string to identify this interpreter in the localization
specified by prtGeneralCurrentLocalization as opposed to the
language which is being interpreted. It is anticipated that
this string will allow manufacturers to unambiguously identify
their interpreters."
::= { prtInterpreterEntry 5 }
prtInterpreterVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date code, version number, or other product specific
information tied to this interpreter. This value is
associated with the interpreter, rather than with the version
of the language which is being interpreted or emulated."
::= { prtInterpreterEntry 6 }
prtInterpreterDefaultOrientation OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
other(1),
portrait(3),
landscape(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current orientation default for this interpreter. This
value may be overridden for a particular job (e.g., by a
command in the input data stream)."
::= { prtInterpreterEntry 7 }
prtInterpreterFeedAddressability OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum interpreter addressability in the feed
direction in 10000 prtMarkerAddressabilityUnit s (see
prtMarkerAddressabilityFeedDir ) for this interpreter.
The value (-1) means other and specifically indicates
that the sub-unit places no restrictions on this parameter."
::= { prtInterpreterEntry 8 }
prtInterpreterXFeedAddressability OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum interpreter addressability in the cross feed
direction in 10000 prtMarkerAddressabilityUnit s (see
prtMarkerAddressabilityXFeedDir) for this interpreter.
The value (-1) means other and specifically indicates
that the sub-unit places no restrictions on this
parameter."
::= { prtInterpreterEntry 9 }
prtInterpreterDefaultCharSetIn OBJECT-TYPE
SYNTAX CodedCharSet
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default coded character set for input octets
encountered outside a context in which the Page
Description Language established the interpretation
of the octets.
This value shall be (2) if there is no default."
::= { prtInterpreterEntry 10 }
prtInterpreterDefaultCharSetOut OBJECT-TYPE
SYNTAX CodedCharSet
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default character set for data coming from this interpreter
through the printer's output channel.
This value shall be (2) if there is no default."
::= { prtInterpreterEntry 11 }
prtInterpreterTwoWay OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
yes(3),
no(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether or not this interpreter returns information
back to the host."
::= { prtInterpreterEntry 12 }
-- The Console Group
--
-- Many printers have a console on the printer, the operator console,
-- that is used to display and modify the state of the printer. The
-- console can be as simple as a few indicators and switches or as
-- complicated as full screen displays and keyboards. There can be
-- at most one such console.
--
-- Implementation of every object in this group is mandatory.
prtConsoleLocalization OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the prtLocalizationIndex corresponding to
the language, country, and character set to be used for the
console. This localization applies both to the actual display
on the console as well as the encoding of these console
objects in management operations."
::= { prtGeneralEntry 10 }
prtConsoleNumberOfDisplayLines OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of lines on the printer's physical
display. This value is 0 if there are no lines on the
physical display or if there is no physical display"
::= { prtGeneralEntry 11 }
prtConsoleNumberOfDisplayChars OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of characters per line displayed on the physical
display. This value is 0 if there are no lines on the
physical display or if there is no physical display"
::= { prtGeneralEntry 12 }
prtConsoleDisable OBJECT-TYPE
SYNTAX INTEGER {
enabled(3),
disabled(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables or disables manual input from the
operators console."
::= { prtGeneralEntry 13 }
-- The Display Buffer Table
prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 }
prtConsoleDisplayBufferTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtConsoleDisplayBufferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { prtConsoleDisplayBuffer 5 }
prtConsoleDisplayBufferEntry OBJECT-TYPE
SYNTAX PrtConsoleDisplayBufferEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one entry for each physical line on
the display. Lines cannot be added or deleted.
Entries may exist in the table for each device
index who's device type is `printer'."
INDEX { hrDeviceIndex, prtConsoleDisplayBufferIndex }
::= { prtConsoleDisplayBufferTable 1 }
PrtConsoleDisplayBufferEntry ::= SEQUENCE {
prtConsoleDisplayBufferIndex Integer32,
prtConsoleDisplayBufferText OCTET STRING
}
prtConsoleDisplayBufferIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value for each console line in the printer. The
value is used to identify this console line. Although
these values may change due to a major reconfiguration of
the device (e.g. the addition of new console lines to the
printer), values are expected to remain stable across
successive printer power cycles."
::= { prtConsoleDisplayBufferEntry 1 }
prtConsoleDisplayBufferText OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The content of a line in the logical display buffer of
the operator's console of the printer. When a write
operation occurs, normally a critical message, to one of
the LineText strings, the agent should make that line
displayable if a physical display is present. Writing
a zero length string clears the line. It is an
implementation-specific matter as to whether the agent allows
a line to be overwritten before it has been cleared.
Printer generated strings shall be in the localization
specified by ConsoleLocalization. Management Application
generated strings should be localized by the Management
Application."
::= { prtConsoleDisplayBufferEntry 2 }
-- The Console Light Table
prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 }
prtConsoleLightTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtConsoleLightEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { prtConsoleLights 6 }
prtConsoleLightEntry OBJECT-TYPE
SYNTAX PrtConsoleLightEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries may exist in the table for each device
index who's device type is `printer'."
INDEX { hrDeviceIndex, prtConsoleLightIndex }
::= { prtConsoleLightTable 1 }
PrtConsoleLightEntry ::= SEQUENCE {
prtConsoleLightIndex Integer32,
prtConsoleOnTime Integer32,
prtConsoleOffTime Integer32,
prtConsoleColor INTEGER,
prtConsoleDescription OCTET STRING
}
prtConsoleLightIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value used by the printer to identify this light.
Although these values may change due to a major
reconfiguration of the device (e.g. the addition of new lights
to the printer), values are expected to remain stable across
successive printer power cycles."
::= { prtConsoleLightEntry 1 }
prtConsoleOnTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The on time in milliseconds of blinking of this light; 0
indicates off always. If both prtConsoleOnTime
and prtConsoleOffTime are 0, then the light is
always off."
::= { prtConsoleLightEntry 2 }
prtConsoleOffTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The off time in milliseconds of blinking of this light; 0
indicates on always. If both prtConsoleOnTime
and prtConsoleOffTime are 0, then the light is
always off."
::= { prtConsoleLightEntry 3 }
prtConsoleColor OBJECT-TYPE
-- This value is a type 2 enumeration
SYNTAX INTEGER {
other(1),
unknown(2),
white(3),
red(4),
green(5),
blue(6),
cyan(7),
magenta(8),
yellow(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The color of this light."
::= { prtConsoleLightEntry 4 }
prtConsoleDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor description or label of this light in the
localization specified by prtConsoleLocalization."
::= { prtConsoleLightEntry 5 }
-- The Alerts Group
--
-- The prtAlertTable lists all the critical and non-critical alerts
-- currently active in the printer. A critical alert is one that stops
-- the printer from printing immediately and printing can not continue
-- until the critical alert condition is eliminated. Non-critical
-- alerts are those items that do not stop printing but may at some
-- future time.
-- The table contains information on the severity, component, detail
-- location within the component, alert code and description of each
-- critical alert that is currently active within the printer. See
-- 2.2.13 for a more complete description of the alerts table and
-- its management.
--
-- Implementation of every object in this group is mandatory.
prtAlert OBJECT IDENTIFIER ::= { printmib 18 }
prtAlertTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtAlertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { prtAlert 1 }
prtAlertEntry OBJECT-TYPE
SYNTAX PrtAlertEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries may exist in the table for each device
index who's device type is `printer'."
INDEX { hrDeviceIndex, prtAlertIndex }
::= { prtAlertTable 1 }
PrtAlertEntry ::= SEQUENCE {
prtAlertIndex Integer32,
prtAlertSeverityLevel INTEGER,
prtAlertTrainingLevel INTEGER,
prtAlertGroup INTEGER,
prtAlertGroupIndex Integer32,
prtAlertLocation Integer32,
prtAlertCode INTEGER,
prtAlertDescription OCTET STRING,
prtAlertTime TimeTicks
}
prtAlertIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index value used to determine which alerts
have been added or removed from the alert table.
This is an incrementing integer starting from zero
every time the printer is reset. When the printer
adds an alert to the table, that alert is assigned
the next higher integer value from the last item
entered into the table. If the index value reaches
its maximum value, the next item entered will cause
the index value to roll over and start at zero
again. The first event placed in the alert table
after a reset of the printer shall
have an index value of 1. NOTE: The management
application will read the alert table when a trap
or event notification occurs or at a periodic rate
and then parse the table to determine if any new
entries were added by comparing the last known index
value with the current highest index value. The
management application will then update its copy of
the alert table. When the printer discovers that
an alert is no longer active, the printer shall
remove the row for that alert from the table and
shall reduce the number of rows in the table. The
printer may add or delete any number of rows from
the table at any time. The management station
can detect when binary alerts have been deleted by
requesting an attribute of each alert, and noting
alerts as deleted when that retrieval is not possible."
::= { prtAlertEntry 1 }
prtAlertSeverityLevel OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
other(1),
critical(3),
warning(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The level of severity of this alert table entry. The printer
determines the severity level assigned to each entry into the
table."
::= { prtAlertEntry 2 }
prtAlertTrainingLevel OBJECT-TYPE
-- This value is a type 2 enumeration
SYNTAX INTEGER {
other(1),
unknown(2),
untrained(3),
trained(4),
fieldService(5),
management(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The level of training required to handle this alert. The
training level is an enumeration that is determined and
assigned by the printer manufacturer based on the information
or the training required to handle this alert. The printer
will break alerts into these different training levels. It is
the responsibility of the management application in the system
to determine how a particular alert is handled and how and to
whom that alert is routed. The following are the four
training levels of alerts:
Field Service - Alerts that typically require advanced
training and technical knowledge of the printer
and its sub-units. An example of a technical
person would be a manufacture's Field Service
representative, or other person formally
trained by the manufacturer or similar
representative.
Trained - Alerts that require an intermediate or moderate
level of knowledge of the printer and its
sub-units. A typical examples of alerts that
a trained operator can handle is replacing
toner cartridges.
Untrained - Alerts that can be fixed without prior
training either because the action to correct
the alert is obvious or the printer can help the
untrained person fix the problem. A typical
example of such an alert is reloading paper
trays and emptying output bins on a low end
printer.
Management - Alerts that have to do with overall
operation of and configuration of the printer.
Examples of management events are configuration
change of sub-units."
::= { prtAlertEntry 3 }
prtAlertGroup OBJECT-TYPE
-- This value is a type 1 enumeration
SYNTAX INTEGER {
other(1),
hostResourcesMIBStorageTable(3),
hostResourcesMIBDeviceTable(4),
generalPrinter(5),
cover(6),
localization(7),
input(8),
output(9),
marker(10),
markerSupplies(11),
markerColorant(12),
mediaPath(13),
channel(14),
interpreter(15),
consoleDisplayBuffer(16),
consoleLights(17)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of sub-unit within the printer model that this alert
is related. Input, output, and markers are examples of
printer model groups, i.e., examples of types of sub-units.
Whereever possible, these enumerations match the
sub-identifier that identifies the relevant table in the
printmib."
::= { prtAlertEntry 4 }
prtAlertGroupIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index of the row within the principle table in the
group identified by prtAlertGroup that represents the
sub-unit of the printer that caused this alert. The
combination of the Group and the GroupIndex defines
exactly which printer sub-unit caused the alert.; for
example, Input #3, Output #2, and Marker #1.
Every object in this MIB is indexed with hrDeviceIndex and
optionally, another index variable. If this other index
variable is present in the table that generated the alert, it
will be used as the value for this object. Otherwise, this
value shall be -1."
::= { prtAlertEntry 5 }
prtAlertLocation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sub-unit location that is defined by the printer
manufacturer to further refine the location of this alert
within the designated sub-unit. The location is used in
conjunction with the Group and GroupIndex values; for
example, there is an alert in Input #2 at location number 7."
::= { prtAlertEntry 6 }
prtAlertCode OBJECT-TYPE
-- This value is a type 2 enumeration
SYNTAX INTEGER {
other(1),
unknown(2),
-- codes common to serveral groups
coverOpen(3),
coverClosed(4),
interlockOpen(5),
interlockClosed(6),
configurationChange(7),
jam(8),
-- general Printer group
doorOpen(501),
doorClosed(502),
powerUp(503),
powerDown(504),
-- Input Group
inputMediaTrayMissing(801),
inputMediaSizeChange(802),
inputMediaWeightChange(803),
inputMediaTypeChange(804),
inputMediaColorChange(805),
inputMediaFormPartsChange(806),
inputMediaSupplyLow(807),
inputMediaSupplyEmpty(808),
-- Output Group
outputMediaTrayMissing(901),
outputMediaTrayAlmostFull(902),
outputMediaTrayFull(903),
-- Marker group
markerFuserUnderTemperature(1001),
markerFuserOverTemperature(1002),
-- Marker Supplies group
markerTonerEmpty(1101),
markerInkEmpty(1102),
markerPrintRibbonEmpty(1103),
markerTonerAlmostEmpty(1104),
markerInkAlmostEmpty(1105),
markerPrintRibbonAlmostEmpty(1106),
markerWasteTonerReceptacleAlmostFull(1107),
markerWasteInkReceptacleAlmostFull(1108),
markerWasteTonerReceptacleFull(1109),
markerWasteInkReceptacleFull(1110),
markerOpcLifeAlmostOver(1111),
markerOpcLifeOver(1112),
markerDeveloperAlmostEmpty(1113),
markerDeveloperEmpty(1114),
-- Media Path Device Group
mediaPathMediaTrayMissing(1301),
mediaPathMediaTrayAlmostFull(1302),
mediaPathMediaTrayFull(1303),
-- interpreter Group
interpreterMemoryIncrease(1501),
interpreterMemoryDecrease(1502),
interpreterCartridgeAdded(1503),
interpreterCartridgeDeleted(1504),
interpreterResourceAdded(1505),
interpreterResourceDeleted(1506),
interpreterResourceUnavailable(1507)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The code that describes the type of alert for this entry in
the table. There are different codes for each
sub-unit type: for example, Media Supply Low and Media
Supply Empty are Aler codes for the Input sub-unit."
::= { prtAlertEntry 7}
prtAlertDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of this alert entry in the localization
specified by prtGeneralCurrentLocalization. The description is
provided by the printer to further elaborate on the enumerated
alert or provide information in the case where the code is
classified ask `other' or `unknown'. The printer is required
to return a description string but the string may be a null
string."
::= { prtAlertEntry 8 }
printerV1Alert OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The value of the enterprise-specific oid in a SNMPv1 trap sent
signalling a critical event in the prtAlertTable."
::= { prtAlert 2 }
printerV2AlertPrefix OBJECT IDENTIFIER ::= { printerV1Alert 0 }
printerV2Alert NOTIFICATION-TYPE
OBJECTS { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup,
prtAlertGroupIndex, prtAlertLocation, prtAlertCode }
STATUS current
DESCRIPTION
"This trap is sent whenever a critical event is added to the
prtAlertTable."
::= { printerV2AlertPrefix 1 }
-- Note that the SNMPv2 to SNMPv1 translation rules dictate that the
-- preceding structure will result in SNMPv1 traps of the following
-- form:
--
-- printerAlert TRAP-TYPE
-- ENTERPRISE printerV1Alert
-- VARIABLES { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup,
-- prtAlertGroupIndex, prtAlertLocation, prtAlertCode }
-- DESCRIPTION
-- "This trap is sent whenever a critical event is added to the
-- prtAlertTable."
-- ::= 1
-- The Alert Time Group
--
-- This group is optional. However, to claim conformance to this
-- group, it is necessary to implement every object in the group.
prtAlertTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time that this alert was
generated."
::= { prtAlertEntry 9 }
-- Conformance Information
prtMIBConformance OBJECT IDENTIFIER ::= { printmib 2 }
-- compliance statements
prtMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for agents that implement the
printer MIB."
MODULE -- this module
MANDATORY-GROUPS { prtGeneralGroup, prtInputGroup, prtOutputGroup,
prtMarkerGroup, prtMediaPathGroup,
prtChannelGroup, prtInterpreterGroup,
prtConsoleGroup, prtAlertTableGroup }
OBJECT prtGeneralReset
SYNTAX INTEGER {
notResetting(3),
resetToNVRAM(5)
}
DESCRIPTION
"It is conformant to implement just these two states in
this object. Any additional states are optional."
OBJECT prtConsoleOnTime
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only."
OBJECT prtConsoleOffTime
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only."
-- the prtResponsiblePartyGroup, prtExtendedInputGroup,
-- prtInputMediaGroup, prtExtendedOutputGroup,
-- prtOutputDimensionsGroup, prtOutputFeaturesGroup,
-- prtMarkerSuppliesGroup, prtMarkerColorantGroup,
-- and the prtAlertTimeGroup are completely optional.
::= { prtMIBConformance 1 }
prtMIBGroups OBJECT IDENTIFIER ::= { prtMIBConformance 2 }
prtGeneralGroup OBJECT-GROUP
OBJECTS { prtGeneralConfigChanges, prtGeneralCurrentLocalization,
prtGeneralReset, prtCoverDescription, prtCoverStatus,
prtLocalizationLanguage, prtLocalizationCountry,
prtLocalizationCharacterSet, prtStorageRefIndex,
prtDeviceRefIndex }
STATUS current
DESCRIPTION
"The general printer group."
::= { prtMIBGroups 1 }
prtResponsiblePartyGroup OBJECT-GROUP
OBJECTS { prtGeneralCurrentOperator, prtGeneralServicePerson }
STATUS current
DESCRIPTION
"The responsible party group contains contact information for
humans responsible for the printer."
::= { prtMIBGroups 2 }
prtInputGroup OBJECT-GROUP
OBJECTS { prtInputDefaultIndex, prtInputType, prtInputDimUnit,
prtInputMediaDimFeedDirDeclared,
prtInputMediaDimXFeedDirDeclared,
prtInputMediaDimFeedDirChosen,
prtInputMediaDimXFeedDirChosen, prtInputCapacityUnit,
prtInputMaxCapacity, prtInputCurrentLevel,
prtInputStatus, prtInputMediaName }
STATUS current
DESCRIPTION
"The input group."
::= { prtMIBGroups 3 }
prtExtendedInputGroup OBJECT-GROUP
OBJECTS { prtInputName, prtInputVendorName, prtInputModel,
prtInputVersion, prtInputSerialNumber,
prtInputDescription, prtInputSecurity }
STATUS current
DESCRIPTION
"The extended input group."
::= { prtMIBGroups 4 }
prtInputMediaGroup OBJECT-GROUP
OBJECTS { prtInputMediaWeight, prtInputMediaType,
prtInputMediaColor, prtInputMediaFormParts }
STATUS current
DESCRIPTION
"The input media group."
::= { prtMIBGroups 5 }
prtOutputGroup OBJECT-GROUP
OBJECTS { prtOutputDefaultIndex, prtOutputType,
prtOutputCapacityUnit, prtOutputMaxCapacity,
prtOutputRemainingCapacity, prtOutputStatus }
STATUS current
DESCRIPTION
"The output group."
::= { prtMIBGroups 6 }
prtExtendedOutputGroup OBJECT-GROUP
OBJECTS { prtOutputName, prtOutputVendorName, prtOutputModel,
prtOutputVersion, prtOutputSerialNumber,
prtOutputDescription, prtOutputSecurity }
STATUS current
DESCRIPTION
"The extended output group."
::= { prtMIBGroups 7 }
prtOutputDimensionsGroup OBJECT-GROUP
OBJECTS { prtOutputDimUnit, prtOutputMaxDimFeedDir,
prtOutputMaxDimXFeedDir, prtOutputMinDimFeedDir,
prtOutputMinDimXFeedDir }
STATUS current
DESCRIPTION
"The output dimensions group"
::= { prtMIBGroups 8 }
prtOutputFeaturesGroup OBJECT-GROUP
OBJECTS { prtOutputStackingOrder,
prtOutputPageDeliveryOrientation, prtOutputBursting,
prtOutputDecollating, prtOutputPageCollated,
prtOutputOffsetStacking }
STATUS current
DESCRIPTION
"The output features group."
::= { prtMIBGroups 9 }
prtMarkerGroup OBJECT-GROUP
OBJECTS { prtMarkerDefaultIndex, prtMarkerMarkTech,
prtMarkerCounterUnit, prtMarkerLifeCount,
prtMarkerPowerOnCount, prtMarkerProcessColorants,
prtMarkerSpotColorants, prtMarkerAddressabilityUnit,
prtMarkerAddressabilityFeedDir,
prtMarkerAddressabilityXFeedDir, prtMarkerNorthMargin,
prtMarkerSouthMargin, prtMarkerWestMargin,
prtMarkerEastMargin, prtMarkerStatus }
STATUS current
DESCRIPTION
"The marker group."
::= { prtMIBGroups 10 }
prtMarkerSuppliesGroup OBJECT-GROUP
OBJECTS { prtMarkerSuppliesMarkerIndex,
prtMarkerSuppliesColorantIndex, prtMarkerSuppliesClass,
prtMarkerSuppliesType, prtMarkerSuppliesDescription,
prtMarkerSuppliesSupplyUnit,
prtMarkerSuppliesMaxCapacity, prtMarkerSuppliesLevel }
STATUS current
DESCRIPTION
"The marker supplies group."
::= { prtMIBGroups 11 }
prtMarkerColorantGroup OBJECT-GROUP
OBJECTS { prtMarkerColorantMarkerIndex, prtMarkerColorantRole,
prtMarkerColorantValue, prtMarkerColorantTonality }
STATUS current
DESCRIPTION
"The marker colorant group."
::= { prtMIBGroups 12 }
prtMediaPathGroup OBJECT-GROUP
OBJECTS { prtMediaPathDefaultIndex, prtMediaPathMaxSpeedPrintUnit,
prtMediaPathMediaSizeUnit, prtMediaPathMaxSpeed,
prtMediaPathMaxMediaFeedDir,
prtMediaPathMaxMediaXFeedDir,
prtMediaPathMinMediaFeedDir,
prtMediaPathMinMediaXFeedDir, prtMediaPathType,
prtMediaPathDescription, prtMediaPathStatus}
STATUS current
DESCRIPTION
"The media path group."
::= { prtMIBGroups 13 }
prtChannelGroup OBJECT-GROUP
OBJECTS { prtChannelType, prtChannelProtocolVersion,
prtChannelCurrentJobCntlLangIndex,
prtChannelDefaultPageDescLangIndex, prtChannelState,
prtChannelIfIndex, prtChannelStatus }
STATUS current
DESCRIPTION
"The channel group."
::= { prtMIBGroups 14 }
prtInterpreterGroup OBJECT-GROUP
OBJECTS { prtInterpreterLangFamily, prtInterpreterLangLevel,
prtInterpreterLangVersion, prtInterpreterDescription,
prtInterpreterVersion, prtInterpreterDefaultOrientation,
prtInterpreterFeedAddressability,
prtInterpreterXFeedAddressability,
prtInterpreterDefaultCharSetIn,
prtInterpreterDefaultCharSetOut, prtInterpreterTwoWay }
STATUS current
DESCRIPTION
"The interpreter group."
::= { prtMIBGroups 15 }
prtConsoleGroup OBJECT-GROUP
OBJECTS { prtConsoleLocalization, prtConsoleNumberOfDisplayLines,
prtConsoleNumberOfDisplayChars, prtConsoleDisable,
prtConsoleDisplayBufferText, prtConsoleOnTime,
prtConsoleOffTime, prtConsoleColor,
prtConsoleDescription }
STATUS current
DESCRIPTION
"The console group."
::= { prtMIBGroups 16 }
prtAlertTableGroup OBJECT-GROUP
OBJECTS { prtAlertSeverityLevel, prtAlertTrainingLevel,
prtAlertGroup, prtAlertGroupIndex, prtAlertLocation,
prtAlertCode, prtAlertDescription }
STATUS current
DESCRIPTION
"The alert table group."
::= { prtMIBGroups 17 }
prtAlertTimeGroup OBJECT-GROUP
OBJECTS { prtAlertTime }
STATUS current
DESCRIPTION
"The alert time group."
::= { prtMIBGroups 18 }
END