135 lines
4.3 KiB
C
135 lines
4.3 KiB
C
|
/*++ BUILD Version: 0001 // Increment this if a change has global effects
|
||
|
|
||
|
Copyright (c) 1995-1999, Microsoft Corporation
|
||
|
|
||
|
Module Name:
|
||
|
|
||
|
wownt16.h
|
||
|
|
||
|
Abstract:
|
||
|
|
||
|
Procedure declarations for functions in WOW32.DLL callable by
|
||
|
3rd-party 16-bit thunking code.
|
||
|
|
||
|
--*/
|
||
|
|
||
|
#ifndef _WOWNT16_
|
||
|
#define _WOWNT16_
|
||
|
|
||
|
#if defined(_MSC_VER)
|
||
|
#if _MSC_VER > 1000
|
||
|
#pragma once
|
||
|
#endif
|
||
|
#endif
|
||
|
|
||
|
#ifdef __cplusplus
|
||
|
extern "C" {
|
||
|
#endif
|
||
|
|
||
|
//
|
||
|
// 16:16 -> 0:32 Pointer translation.
|
||
|
//
|
||
|
// GetVDMPointer32W will convert the passed in 16-bit address
|
||
|
// to the equivalent 32-bit flat pointer. The upper 16 bits
|
||
|
// of the address are treated according to the value passed in
|
||
|
// fMode: if fMode = 1, then the hiword of vp is used as a
|
||
|
// protected mode selector. Otherwise it is used as a real mode
|
||
|
// segment value.
|
||
|
// The lower 16 bits are treated as the offset.
|
||
|
//
|
||
|
// The return value is 0 if the selector is invalid.
|
||
|
//
|
||
|
// NOTE: Limit checking is not performed in the retail build
|
||
|
// of Windows NT. It is performed in the checked (debug) build
|
||
|
// of WOW32.DLL, which will cause 0 to be returned when the
|
||
|
// limit is exceeded by the supplied offset.
|
||
|
//
|
||
|
|
||
|
DWORD FAR PASCAL GetVDMPointer32W(LPVOID vp, UINT fMode);
|
||
|
|
||
|
|
||
|
//
|
||
|
// Win32 module management.
|
||
|
//
|
||
|
// The following routines accept parameters that correspond directly
|
||
|
// to the respective Win32 API function calls that they invoke. Refer
|
||
|
// to the Win32 reference documentation for more detail.
|
||
|
|
||
|
DWORD FAR PASCAL LoadLibraryEx32W(LPCSTR lpszLibFile, DWORD hFile, DWORD dwFlags);
|
||
|
DWORD FAR PASCAL GetProcAddress32W(DWORD hModule, LPCSTR lpszProc);
|
||
|
DWORD FAR PASCAL FreeLibrary32W(DWORD hLibModule);
|
||
|
|
||
|
//
|
||
|
// Generic Thunk Routine:
|
||
|
//
|
||
|
// CallProc32W
|
||
|
//
|
||
|
// Transitions to 32 bits and calls specified routine
|
||
|
//
|
||
|
// This routine can pass a variable number of arguments, up to 32, to the
|
||
|
// target 32-bit routine. These arguments are given to CallProc32W following
|
||
|
// the 3 required parameters.
|
||
|
//
|
||
|
// DWORD cParams - Number of optional DWORD parameters (0-32)
|
||
|
//
|
||
|
// LPVOID fAddressConvert - Bit Field, for 16:16 address Convertion. The
|
||
|
// optional parameters can be automatically converted
|
||
|
// from a 16:16 address format to flat by specifying
|
||
|
// a 1 bit in the corresponding position in this mask.
|
||
|
// eg (bit 1 means convert parameter 1 from 16:16
|
||
|
// to flat address before calling routine)
|
||
|
//
|
||
|
// DWORD lpProcAddress - 32 bit native address to call (use LoadLibraryEx32W
|
||
|
// and GetProcAddress32W to get this address).
|
||
|
//
|
||
|
// Returns:
|
||
|
// What ever the API returned on 32 bit side in AX:DX
|
||
|
//
|
||
|
// Error Returns:
|
||
|
// AX = 0, more than 32 parameters.
|
||
|
//
|
||
|
//
|
||
|
// The function prototype must be declared by the application source code
|
||
|
// in the following format:
|
||
|
//
|
||
|
// DWORD FAR PASCAL CallProc32W( DWORD p1, ... , DWORD lpProcAddress,
|
||
|
// DWORD fAddressConvert, DWORD cParams);
|
||
|
//
|
||
|
// where the value in cParams must match the actual number of optional
|
||
|
// parameters (p1-pn) given AND the "DWORD p1, ..." must be replaced by
|
||
|
// the correct number of parameters being passed. For example, passing 3
|
||
|
// parameter would simply require the removal of the ... and it insertion of
|
||
|
// "DWORD p2, DWORD p3" instead. The fAddressConvert parameter uses bit 1
|
||
|
// for the last parameter (p3 in our example), with bit 2 for the next to last,
|
||
|
// etc.
|
||
|
//
|
||
|
// Generic Thunk Routine:
|
||
|
//
|
||
|
// CallProcEx32W
|
||
|
//
|
||
|
// Transitions to 32 bits and calls specified routine
|
||
|
//
|
||
|
// Similar to the CallProc32W function, the CallProcEx32W is an equivalent
|
||
|
// function that is C calling convention and allows easier and more flexible
|
||
|
// prototyping. See the prototype below. The fAddressConvert parameter uses
|
||
|
// bit 1 for the 1st parameter, bit 2 for the 2nd parameter, etc.
|
||
|
//
|
||
|
// Both CallProc32W and CallProcEx32W accept a flag OR'd with the parameter
|
||
|
// count to indicate the calling convention of the function in 32 bits.
|
||
|
// For example, to call a cdecl function in 32-bits with 1 parameter, it would
|
||
|
// look like this:
|
||
|
//
|
||
|
// dwResult = CallProcEx32W( CPEX_DEST_CDECL | 1, 0, dwfn32, p1 );
|
||
|
//
|
||
|
|
||
|
DWORD FAR CDECL CallProcEx32W( DWORD, DWORD, DWORD, ... );
|
||
|
|
||
|
#define CPEX_DEST_STDCALL 0x00000000L
|
||
|
#define CPEX_DEST_CDECL 0x80000000L
|
||
|
|
||
|
#ifdef __cplusplus
|
||
|
}
|
||
|
#endif
|
||
|
|
||
|
#endif /* !_WOWNT16_ */
|