;/****************************************************************************** ;* $ProjectName: $ ;* $ProjectRevision: $ ;*----------------------------------------------------------------------------- ;* $Source: z:/pr/cmapiifd/sw/sccmn50m.ms/rcs/sccmlog.mc $ ;* $Revision: 1.1 $ ;*----------------------------------------------------------------------------- ;* $Author: TBruendl $ ;*----------------------------------------------------------------------------- ;* History: see EOF ;*----------------------------------------------------------------------------- ;* ;* Copyright © 1996-99 Utimaco Safeware AG ;******************************************************************************/ ;#ifndef _SCCMLOG ;#define _SCCMLOG ; ;// ;// Status values are 32 bit values layed out as follows: ;// ;// 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 ;// 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 ;// +---+-+-------------------------+-------------------------------+ ;// |Sev|C| Facility | Code | ;// +---+-+-------------------------+-------------------------------+ ;// ;// where ;// ;// Sev - is the severity code ;// ;// 00 - Success ;// 01 - Informational ;// 10 - Warning ;// 11 - Error ;// ;// C - is the Customer code flag ;// ;// Facility - is the facility code ;// ;// Code - is the facility's status code ;// ; MessageIdTypedef=NTSTATUS SeverityNames=(Success=0x0:STATUS_SEVERITY_SUCCESS Informational=0x1:STATUS_SEVERITY_INFORMATIONAL Warning=0x2:STATUS_SEVERITY_WARNING Error=0x3:STATUS_SEVERITY_ERROR ) FacilityNames=(System=0x0 RpcRuntime=0x2:FACILITY_RPC_RUNTIME RpcStubs=0x3:FACILITY_RPC_STUBS Io=0x4:FACILITY_IO_ERROR_CODE Smartcard=0x10:FACILITY_SCARD ) MessageId=0x0001 Facility=Io Severity=Error SymbolicName=SCCMN50M_CANT_CREATE_DEVICE Language=English A new device cannot be created due to an system call failure. . MessageId=0x0002 Facility=Io Severity=Error SymbolicName=SCCMN50M_NO_MEMORY Language=English The system does not have enough memory. . MessageId=0x0003 Facility=Smartcard Severity=Error SymbolicName=SCCMN50M_BUFFER_TOO_SMALL Language=English An internal i/o buffer is too small. . MessageId=0x0004 Facility=Io Severity=Error SymbolicName=SCCMN50M_CANT_CONNECT_TO_ASSIGNED_PORT Language=English Internal error: Cannot connect to assigned serial port. . MessageId=0x0005 Facility=Io Severity=Error SymbolicName=SCCMN50M_CANT_CREATE_MORE_DEVICES Language=English The maximum number of devices has already been created. A new device cannot be created. . MessageId=0x0006 Facility=Io Severity=Informational SymbolicName=SCCMN50M_WRONG_LIB_VERSION Language=English The version of the dependency driver smclib.sys is not compatbile to this driver. . MessageId=0x0007 Facility=Io Severity=Informational SymbolicName=SCCMN50M_IRQ_BUSY Language=English The current serial port cannot be used because it uses a shared interrupt which is already in use. Please connect the smart card reader to a different serial port. . ;#endif /* _SCCMLOG */ ;/***************************************************************************** ;* History: ;* $Log: sccmlog.mc $ ;* Revision 1.1 2000/03/29 06:07:48 TBruendl ;* No comment given ;* ;* Revision 1.1 1999/02/02 13:34:38 TBruendl ;* This is the first release (R01.00) of the IFD handler for CardMan running under NT5.0. ;* ;* ;*****************************************************************************/