#include "ups.h" //#include "control.rcv" UPSICON ICON PRELOAD ups.ico CP_ACCEL ACCELERATORS PRELOAD BEGIN VK_F1, MENU_INDHELP, VIRTKEY END #include "ups.dlg" STRINGTABLE DISCARDABLE LOADONCALL BEGIN /* initialization strings */ ERRMEM, "Insufficient memory for this operation." LSFAIL, "LoadString fail due to the string resource does not exist." CPCAPTION, "Control Panel" /* for message box titles */ _STOPPED, "Stopped" _START_PENDING, "Start_pending" _STOP_PENDING, "Stop_pending" _RUNNING, "running" _CONTINUE_PENDING, "Continue_pending" _PAUSE_PENDING, "Pause_pending" _PAUSED, "Paused" UPS_STATUS_ERROR, "The status of the UPS service is unknown." UPS_REGISTRY_ERROR, "Cannot read/save UPS information in the registry." CHILDREN, "&UPS" INFO, "Configures the Uninterruptible Power Supply" UPS_OPTIONS_ERROR, "The UPS must support signal on either low battery or power failure." UPS_ACCESS_ERROR, "You do not have access to set UPS options." UPS_SERVICE_ERROR, "Cannot restart UPS service. Please restart the system." UPS_FW_WARNING, "Time before first warning message is greater than the battery life." UPS_DELAY_WARNING, "Time between Warning messages is greater than the battery life." UPS_FWRange, "Time between power failure and initial warning message is out of the valid range. (0-120 sec)" UPS_WIRange, "Delay between warning message is out of the valid range. (5-300 sec)" UPS_BLRange, "Expected Battery Life is out of the valid range. (2-720 min)" UPS_RPMRange, "Battery recharge time per minute of run time is out of the valid range. (1-250 min)" UPS_START_MSG, "The UPS service has not been started. Would you like to start it now?" UPS_RESTART_MSG, "The UPS service is running. Would you like to restart it now?" UPS_STOP_MSG, "The UPS service is running. Would you like to stop it now?" UPS_PENDING_MSG, "The UPS service is in a pending state. Use the Services applet in the Control Panel." UPS_STARTFAIL_MSG,"Could not start the UPS service. Check the connections and the interface signals." UPS_STOPFAIL_MSG, "Could not stop the UPS service. Use the Services applet in the Control Panel." UPS_UNKNOWNSTATE_MSG, "The UPS service is in an unknown state. Use the Services applet in the Control Panel." UPS_INVALID_PATH, "The command file specified is not valid. Please specify the filename only." UPS_INVALID_FILENAME, "The command file specified is not valid." UPS_FILE_NOT_EXIST, "The command file specified does not exist on your %1 directory." UPS_CANT_FIND_SYSDIR, "Cannot find the system directory." END #include #define VER_FILETYPE VFT_DLL #define VER_FILESUBTYPE VFT2_UNKNOWN #define VER_FILEDESCRIPTION_STR "Control Panel UPS Applet" #define VER_INTERNALNAME_STR "ups\0" #include "common.ver"