268 lines
6 KiB
C
268 lines
6 KiB
C
/*++
|
|
|
|
Copyright (c) 1999 Microsoft Corporation
|
|
|
|
Module Name:
|
|
|
|
Shutdown.c
|
|
|
|
Abstract:
|
|
|
|
This module contains the server side implementation for the Win32 remote
|
|
shutdown APIs, that is:
|
|
|
|
- BaseInitiateSystemShutdown
|
|
- BaseAbortSystemShutdown
|
|
- BaseInitiateSystemShutdownEx
|
|
|
|
Author:
|
|
|
|
Dragos C. Sambotin 18-May-1999
|
|
|
|
Notes:
|
|
|
|
These server side APIs are just stubs RPCalling in the winlogon's shutdown
|
|
interface. They are provided only for backward compatibility. When support
|
|
for older versions is dropped, these stubs can be removed.
|
|
|
|
Revision History:
|
|
|
|
--*/
|
|
|
|
|
|
#define UNICODE
|
|
|
|
#include <rpc.h>
|
|
#include "regrpc.h"
|
|
#include "shutinit.h"
|
|
#include "..\regconn\regconn.h"
|
|
|
|
|
|
ULONG
|
|
BaseInitiateSystemShutdown(
|
|
IN PREGISTRY_SERVER_NAME ServerName,
|
|
IN PUNICODE_STRING lpMessage OPTIONAL,
|
|
IN DWORD dwTimeout,
|
|
IN BOOLEAN bForceAppsClosed,
|
|
IN BOOLEAN bRebootAfterShutdown
|
|
)
|
|
/*++
|
|
|
|
Routine Description:
|
|
|
|
This routine is provided for backward compatibility. It does nothing
|
|
|
|
Arguments:
|
|
|
|
ServerName - Name of machine this server code is running on. (Ignored)
|
|
|
|
lpMessage - message to display during shutdown timeout period.
|
|
|
|
dwTimeout - number of seconds to delay before shutting down
|
|
|
|
bForceAppsClosed - Normally applications may prevent system shutdown.
|
|
- If this true, all applications are terminated unconditionally.
|
|
|
|
bRebootAfterShutdown - TRUE if the system should reboot. FALSE if it should
|
|
- be left in a shutdown state.
|
|
|
|
Return Value:
|
|
|
|
Returns ERROR_SUCCESS (0) for success; error-code for failure.
|
|
|
|
--*/
|
|
|
|
{
|
|
DWORD Result;
|
|
SHUTDOWN_CONTEXT ShutdownContext;
|
|
RPC_STATUS RpcStatus ;
|
|
|
|
//
|
|
// If we are here, we have been called by an NT4 or Win9x machine
|
|
// which doesn't know about the new interface
|
|
//
|
|
|
|
//
|
|
// Explicitly bind to the given server.
|
|
//
|
|
if (!ARGUMENT_PRESENT(ServerName)) {
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
RpcStatus = RpcImpersonateClient( NULL );
|
|
|
|
if ( RpcStatus != 0 )
|
|
{
|
|
return RpcStatus ;
|
|
}
|
|
|
|
//
|
|
// do it locally
|
|
//
|
|
ServerName = L"";
|
|
ShutdownContext.dwTimeout = dwTimeout;
|
|
ShutdownContext.bForceAppsClosed = (bForceAppsClosed != 0);
|
|
ShutdownContext.bRebootAfterShutdown = (bRebootAfterShutdown != 0);
|
|
|
|
//
|
|
// delegate the call to the new interface
|
|
//
|
|
|
|
Result = BaseBindToMachineShutdownInterface(ServerName,
|
|
NewShutdownCallback,
|
|
lpMessage,
|
|
&ShutdownContext);
|
|
|
|
RevertToSelf();
|
|
|
|
return Result;
|
|
}
|
|
|
|
ULONG
|
|
BaseInitiateSystemShutdownEx(
|
|
IN PREGISTRY_SERVER_NAME ServerName,
|
|
IN PUNICODE_STRING lpMessage OPTIONAL,
|
|
IN DWORD dwTimeout,
|
|
IN BOOLEAN bForceAppsClosed,
|
|
IN BOOLEAN bRebootAfterShutdown,
|
|
IN DWORD dwReason
|
|
)
|
|
/*++
|
|
|
|
Routine Description:
|
|
|
|
This routine is provided for backward compatibility. It does nothing
|
|
|
|
Arguments:
|
|
|
|
ServerName - Name of machine this server code is running on. (Ignored)
|
|
|
|
lpMessage - message to display during shutdown timeout period.
|
|
|
|
dwTimeout - number of seconds to delay before shutting down
|
|
|
|
bForceAppsClosed - Normally applications may prevent system shutdown.
|
|
- If this true, all applications are terminated unconditionally.
|
|
|
|
bRebootAfterShutdown - TRUE if the system should reboot. FALSE if it should
|
|
- be left in a shutdown state.
|
|
|
|
dwReason - Reason for initiating the shutdown. This reason is logged
|
|
in the eventlog #6006 event.
|
|
|
|
Return Value:
|
|
|
|
Returns ERROR_SUCCESS (0) for success; error-code for failure.
|
|
|
|
--*/
|
|
|
|
{
|
|
DWORD Result;
|
|
SHUTDOWN_CONTEXTEX ShutdownContext;
|
|
RPC_STATUS RpcStatus ;
|
|
|
|
//
|
|
// If we are here, we have been called by an NT4 or Win9x machine
|
|
// which doesn't know about the new interface
|
|
//
|
|
|
|
//
|
|
// Explicitly bind to the given server.
|
|
//
|
|
if (!ARGUMENT_PRESENT(ServerName)) {
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
RpcStatus = RpcImpersonateClient( NULL );
|
|
|
|
if ( RpcStatus != 0 )
|
|
{
|
|
return RpcStatus ;
|
|
}
|
|
|
|
// do it locally
|
|
ServerName = L"";
|
|
ShutdownContext.dwTimeout = dwTimeout;
|
|
ShutdownContext.bForceAppsClosed = (bForceAppsClosed != 0);
|
|
ShutdownContext.bRebootAfterShutdown = (bRebootAfterShutdown != 0);
|
|
ShutdownContext.dwReason = dwReason;
|
|
|
|
//
|
|
// delegate the call to the new interface
|
|
//
|
|
|
|
Result = BaseBindToMachineShutdownInterface(ServerName,
|
|
NewShutdownCallbackEx,
|
|
lpMessage,
|
|
&ShutdownContext);
|
|
|
|
RevertToSelf();
|
|
|
|
return Result;
|
|
}
|
|
|
|
ULONG
|
|
BaseAbortSystemShutdown(
|
|
IN PREGISTRY_SERVER_NAME ServerName
|
|
)
|
|
/*++
|
|
|
|
Routine Description:
|
|
|
|
This routine is provided for backward compatibility. It does nothing
|
|
|
|
Arguments:
|
|
|
|
ServerName - Name of machine this server code is running on. (Ignored)
|
|
|
|
Return Value:
|
|
|
|
Returns ERROR_SUCCESS (0) for success; error-code for failure.
|
|
|
|
--*/
|
|
|
|
{
|
|
DWORD Result;
|
|
RPC_BINDING_HANDLE binding;
|
|
RPC_STATUS RpcStatus ;
|
|
|
|
//
|
|
// If we are here, we have been called by an NT4 or Win9x machine
|
|
// which doesn't know about the new interface
|
|
//
|
|
|
|
//
|
|
// Explicitly bind to the given server.
|
|
//
|
|
if (!ARGUMENT_PRESENT(ServerName)) {
|
|
return ERROR_SUCCESS;
|
|
}
|
|
|
|
//
|
|
// Call the server
|
|
//
|
|
|
|
RpcStatus = RpcImpersonateClient( NULL );
|
|
|
|
if ( RpcStatus != 0 )
|
|
{
|
|
return RpcStatus ;
|
|
}
|
|
|
|
// do it locally
|
|
ServerName = L"";
|
|
|
|
//
|
|
// delegate the call to the new interface
|
|
//
|
|
Result = BaseBindToMachineShutdownInterface(ServerName,
|
|
NewAbortShutdownCallback,
|
|
NULL,
|
|
NULL);
|
|
|
|
RevertToSelf();
|
|
|
|
return Result;
|
|
}
|
|
|