'* File: ADPlus.vbs
|
|
'* Version: 4.01
|
|
'* Date: 5/29/2001
|
|
'* Author: Robert Hensing, Solution Integration Engineering
|
|
'* Purpose: AutodumpPlus is used to automatically generate memory dumps or log files containing
|
|
'* scripted debug output usefull for troubleshooting N-tier WinDNA / .Net applications.
|
|
'* Since WinDNA / .Net applications often encompass multiple, interdependent
|
|
'* processes on one or more machines, when troubleshooting an application hang
|
|
'* or crash it is often necessary to 'look' at all of the processes at the same time.
|
|
'* AutodumpPlus allows you to profile an application that may be hanging by taking
|
|
'* 'snapshots' (memory dumps, or debug log files) of that application and all of
|
|
'* its processes, all at the same time. Multiple 'snapshots' can then be compared
|
|
'* or analyzed to build a history or profile of an application over time.
|
|
'*
|
|
'* In addition to taking 'snapshots' of hung/non-responsive WinDNA / .Net applications
|
|
'* AutodumpPlus can be used to troubleshoot applications that are crashing or throwing
|
|
'* unhandled exceptions which can lead to a crash.
|
|
'* Usage:
|
|
'* AutodumpPlus has 3 modes of operation: 'Hang', 'Quick' and 'Crash' mode.
|
|
'*
|
|
'* In 'Hang' mode, AutodumpPlus assumes that a process is hung and it will attach a
|
|
'* debugger to the process(s) specified on the command line with either the '-p'
|
|
'* or '-pn' or '-iis' switches. After the debugger is attached to the process(s)
|
|
'* AutodumpPlus will dump the memory of each process to a .dmp file for later analysis
|
|
'* with a debugger (such as WinDBG). In this mode, processes are paused briefly
|
|
'* while their memory is being dumped to a file and then resumed.
|
|
'*
|
|
'* In '-quick' mode AutodumpPlus assumes that a process is hung and it will attach a
|
|
'* debugger to the process(s) specified on the command line with either the '-p'
|
|
'* or '-pn' or '-iis' switches. After the debugger is attached to the process(s)
|
|
'* AutodumpPlus will create text files for each process, containing commonly requested
|
|
'* debug information, rather than dumping the entire memory for each process.
|
|
'* 'Quick' mode is generally faster than 'Hang' mode, but requires symbols to be
|
|
'* installed on the server where AutodumpPlus is running.
|
|
'*
|
|
'* In 'Crash' mode, AutodumpPlus assumes that a process will crash and it will attach
|
|
'* a debugger to the process(s) specified on the command line with either the '-p'
|
|
'* or '-pn' or '-iis' switches. After the debugger is attached to the process(s)
|
|
'* AutodumpPlus will configure the debugger to log 'first chance' access violations
|
|
'* (AV's) to a text file. When a 'second chance' access violation occurs, the
|
|
'* processes memory is dumped to a .dmp file for analysis with a debugger such as
|
|
'* WinDBG. In this mode, a debugger remains attached to the process(s) until the
|
|
'* process exits or the debugger is exited by pressing CTRL-C in the minimized
|
|
'* debugger window. When the process crashes, or CTRL-C is pressed, it will
|
|
'* need to be re-started.
|
|
'*
|
|
'* For more information on using AutodumpPlus, please refer to the following KB:
|
|
'* http://support.microsoft.com/support/kb/articles/q286/3/50.asp
|
|
'***********************************************************************************************
|
|
'*--------------------------------------------------------------------------
|
|
'*
|
|
'* Switches: '-hang', '-quick', '-crash', '-iis', '-p <PID>', '-pn <Process Name>
|
|
'* '-pageheap', '-quiet', '-o <output directory>, '-notify <target>
|
|
'*
|
|
'*
|
|
'* Required: ('-hang', or '-quick', or '-crash') AND ('-iis' or '-p' or '-pn')
|
|
'*
|
|
'* Optional: '-pageheap', '-quiet', '-o <outputdir>', '-notify <computer>'
|
|
'*
|
|
'* Examples: 'ADPlus -hang -iis', Produces memory dumps of IIS and all
|
|
'* MTS/COM+ packages currently running.
|
|
'*
|
|
'* 'ADPlus -crash -p 1896', Attaches the debugger to process with PID
|
|
'* 1896, and monitors it for 1st and 2nd
|
|
'* chance access violations (crashes).
|
|
'*
|
|
'* 'ADPlus -quick -pn mmc.exe', Attaches the debugger to all instances
|
|
'* of MMC.EXE and dumps debug information
|
|
'* about these processes to a text file.
|
|
'*
|
|
'* 'ADPlus -?' or 'ADPlus -help': Displays detailed help.
|
|
'*-------------------------------------------------------------------------------
|
|
'For more information on using AutodumpPlus, please refer to the following KB:
|
|
'http://support.microsoft.com/support/kb/articles/q286/3/50.asp
|
|
'****************************************************************************
|
|
|
|
Option Explicit
|
|
|
|
' These are AutodumpPlus's constants. By default, they should all be set to FALSE for performance reasons.
|
|
' These constants should only be set to TRUE for troubleshooting script problems or producing verbose debug
|
|
' information. Setting some of these constant to TRUE can have a performance impact on production servers.
|
|
|
|
' Set DEBUGGING = TRUE to turn on verbose debug output, usefull for troubleshooting ADPlus problems.
|
|
Const DEBUGGING = FALSE
|
|
|
|
' Set Full_Dump_on_CONTRL_C to TRUE if you wish to have ADPlus produce a full memory dump (as opposed to a
|
|
' mini-memory dump) whenever CTRL-C is pressed to stop debugging, when running in 'crash' mode.
|
|
' Note: Depending upon the number of processes being monitored, this could generate a signifigant amount
|
|
' of memory dumps.
|
|
Const Full_Dump_on_CONTRL_C = FALSE
|
|
|
|
' Set Create_Full_Dump_on_1st_Chance_Exception to TRUE if you wish to have ADPlus produce a full memory dump
|
|
' for the process each time a 1st chance exception is encountered. This is disabled by default for performance reasons.
|
|
' This is particulairly usefull if troubleshooting MTS or COM+ packages that get shut down after a 1st chance
|
|
' unhandled exception and do not reach a 2nd chance exception state before the process is shut down.
|
|
Const Create_Full_Dump_on_1st_Chance_Exception = FALSE
|
|
|
|
' Set No_Dump_on_1st_Chance_Exception to TRUE if you wish to have ADPlus not produce any memory dumps
|
|
' when 1st chance exceptions are encountered. You may wish to do this if a very high rate of 1st chance
|
|
' exceptions is encountered (i.e. hundreds per minute) and the debugger is spending too much time producing mini-memory dumps
|
|
' causing the process to appear hung.
|
|
' NOTE: This constant should NOT be set to TRUE if Create_Full_Dump_on_1st_Chance_Exception (above) is ALSO set to TRUE
|
|
' as this would produce mutually exclusive behavior.
|
|
Const No_Dump_on_1st_Chance_Exception = FALSE
|
|
|
|
' Set Dump_on_EH_Exceptions to TRUE if you wish to have ADPlus and produce a memory dump each time
|
|
' a C++ EH exception is encountered. This is disabled by default for performance reasons.
|
|
Const Dump_on_EH_Exceptions = FALSE
|
|
|
|
' Set Dump_on_Unknown_Exceptions = TRUE if you wish to have ADPlus produce a memory dump each time
|
|
' an unknown exception is encountered. This is disabled by default for performance reasons.
|
|
Const Dump_on_Unknown_Exceptions = FALSE
|
|
|
|
' Set Dump_Stack_on_DLL_Load = TRUE if you wish to have ADPlus dump the stack each time
|
|
' a DLL is loaded. This is disabled by default for performance reasons.
|
|
Const Dump_Stack_on_DLL_Load = FALSE
|
|
|
|
' Set Dump_Stack_on_DLL_Load_Unload = TRUE if you wish to have ADPlus dump the stack each time
|
|
' a DLL is unloaded. This is disabled by default for performance reasons.
|
|
Const Dump_Stack_on_DLL_UnLoad = FALSE
|
|
|
|
' Set No_CrashMode_Log = TRUE if you do NOT want ADPlus to create a log file in Crash Mode. If a process is generating
|
|
' a lot of exceptions, the debug log file created in crash mode could become quite large.
|
|
Const No_CrashMode_Log = FALSE
|
|
|
|
' Set No_Free_Space_Checking = TRUE if you do NOT want ADPlus to check for free space before running. Certain RAID drivers
|
|
' can cause problems for the free space checking routines and it may be necessary to set this to TRUE to allow ADPlus to run.
|
|
Const No_Free_Space_Checking = FALSE
|
|
|
|
' Set MAX_APPLICATIONS_TO_DEBUG to whatever upper limit you wish to impose on the -IIS switch.
|
|
' By default MAX_APPLICATIONS_TO_DEBUG defaults to 20 to limit the number of MTS or COM+ applications ADPlus will dump / monitor.
|
|
' NOTE: If there are 30 running MTS or COM+ applications and MAX_APPLICATIONS_TO_DEBUG is set to 20, ADPlus will display
|
|
' an error message indicating that there are too many applications running and it will quit.
|
|
Const MAX_APPLICATIONS_TO_DEBUG = 20
|
|
|
|
' AudotumpPlus version
|
|
Const VERSION = "4.01"
|
|
|
|
' The following constants are used by ADPlus for launching command shells and for the FileSystemObject.
|
|
' These constants should NOT be changed.
|
|
Const MINIMIZE_NOACTIVATE = 7
|
|
Const ACTIVATE_AND_DISPLAY = 1
|
|
Const ForReading = 1, ForWriting = 2, ForAppending = 8
|
|
Const TristateUseDefault = -2, TristateTrue = -1, TristateFalse = 0
|
|
|
|
' AutodumpPlus's global variables
|
|
Dim objArgs
|
|
Dim objShell
|
|
Dim objFileSystem
|
|
Dim objFolder
|
|
Dim HangMode
|
|
Dim IISMode
|
|
Dim QuickMode
|
|
Dim QuietMode
|
|
Dim CrashMode
|
|
Dim PageHeapMode
|
|
Dim OSwitchUsed
|
|
Dim OSVer
|
|
Dim OSBuildNumber
|
|
Dim ComputerName
|
|
Dim LogDir
|
|
Dim CDBScriptsDir
|
|
Dim CDBScriptName
|
|
Dim InstallDir
|
|
Dim ShortInstallDir
|
|
Dim OutPutDir
|
|
Dim OutPutDirShortPath
|
|
Dim PackageCount
|
|
Dim ErrorsDuringRuntime
|
|
Dim HangDir
|
|
Dim ShortHangDir
|
|
Dim CrashDir
|
|
Dim ShortCrashDir
|
|
Dim IISPid
|
|
Dim IISVer
|
|
Dim IISProcessCount
|
|
Dim GenericProcessPIDDictionary
|
|
Dim GenericProcessNameDictionary
|
|
Dim GenericModePID
|
|
Dim GenericModeProcessName
|
|
Dim DumpGenericProcess
|
|
Dim DateTimeStamp
|
|
Dim strPackageName
|
|
Dim NotifyAdmin
|
|
Dim NotifyTarget
|
|
Dim LocalUserName
|
|
Dim SymPathError
|
|
Dim WinDir
|
|
Dim EightDotThreePath
|
|
Dim EightDotThreeValue
|
|
|
|
|
|
' Initialize global variables to default values
|
|
Set GenericProcessPIDDictionary = CreateObject("Scripting.Dictionary")
|
|
Set GenericProcessNameDictionary = CreateObject("Scripting.Dictionary")
|
|
PackageCount = 0
|
|
IISProcessCount = 0
|
|
ErrorsDuringRuntime = false
|
|
HangMode = false
|
|
IISMode = false
|
|
QuickMode = false
|
|
QuietMode = false
|
|
CrashMode = false
|
|
GenericModePID = false
|
|
GenericModeProcessName = false
|
|
DumpGenericProcess = false
|
|
OSwitchUsed = false
|
|
NotifyAdmin = false
|
|
EightDotThreePath = "HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\FileSystem\NTFSDisable8Dot3NameCreation"
|
|
|
|
On Error Resume Next
|
|
|
|
' Get the installation directory name, used for verifying required files are present.
|
|
Set objShell = createobject("Wscript.shell")
|
|
Set objFileSystem = CreateObject("Scripting.FileSystemObject")
|
|
|
|
|
|
'Check to see if NTFSDisable8Dot3NameCreation is set to 1
|
|
'If so then display an error and then exit to work around an issue with the Scripting.FileSystemObject's shortpath method.
|
|
EightDotThreeValue = objShell.RegRead(EightDotThreePath)
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "-----------------------"
|
|
wscript.echo "In InitializeAutodump, checking the following registry key: " & EightDotThreePath
|
|
wscript.echo "Err.number after reading key: " & err.number
|
|
wscript.echo "Err.Description after reading key: " & err.description
|
|
wscript.echo "-----------------------"
|
|
err.clear
|
|
End If
|
|
|
|
If EightDotThreeValue = 1 Then 'Its TRUE, display an error and quit
|
|
If QuietMode = False Then
|
|
objShell.Popup "AutodumpPlus has detected that the following registry value " & EightDotThreePath & " is set to 1. AutodumpPlus will not work properly with 8.3 path's disabled. Please set this value to 0 and reboot the server before running AutodumpPlus again.",,"AutoDumpPlus", 0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus has detected that the following registry value " & EightDotThreePath & " is set to 1. AutodumpPlus will not work properly with 8.3 path's disabled. Please set this value to 0 and reboot the server before running AutodumpPlus again."
|
|
wscript.echo "AutodumpPlus has detected that the following registry value " & EightDotThreePath & " is set to 1. AutodumpPlus will not work properly with 8.3 path's disabled. Please set this value to 0 and reboot the server before running AutodumpPlus again."
|
|
End If
|
|
wscript.quit 1
|
|
Else
|
|
|
|
End If
|
|
|
|
|
|
|
|
InstallDir = Left(wscript.scriptfullname,Len(wscript.scriptfullname)-Len(wscript.scriptname)-1)
|
|
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "-----------------------------------------------------------"
|
|
wscript.echo "Initial info, prior to calling any functions . . ."
|
|
wscript.echo "The Wscript.scriptfullname is: " & Wscript.scriptfullname
|
|
wscript.echo "The Install Directory is: " & InstallDir
|
|
End If
|
|
|
|
Set objFolder = objFileSystem.GetFolder(InstallDir)
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "Trying to call objFileSystem.GetFolder on: " & InstallDir
|
|
Wscript.echo "Error number after calling objFileSystem.GetFolder = " & err.number
|
|
Wscript.echo "Error description: " & err.description
|
|
If InstallDir = "" Then
|
|
Wscript.quit 1
|
|
End If
|
|
End If
|
|
err.clear
|
|
|
|
ShortInstallDir = objFolder.ShortPath
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "Trying to get ShortInstallDir . . ."
|
|
Wscript.echo "Error number after calling objFolder.Shortpath = " & err.number
|
|
Wscript.echo "Error description: " & err.description
|
|
Wscript.echo "ShortInstallDir = " & ShortInstallDir
|
|
wscript.echo " ------------------------------------------------------------"
|
|
If ShortInstallDir = "" Then
|
|
Wscript.quit 1
|
|
End If
|
|
End If
|
|
|
|
If ShortInstallDir = "" Then
|
|
objShell.Popup "AutodumpPlus encountered an error trying to get the short path name for the following directory: " & InstallDir & ". AutodumpPlus can not continue.",,"AutodumpPlus",0
|
|
Wscript.quit 1
|
|
End If
|
|
|
|
err.clear
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: Main
|
|
' The following subroutines and functions provide the core functionality for
|
|
' AutodumpPlus. All core functionality should be encapsulated in these sub's or functions.
|
|
'---------------------------------------------------------------------------------------------
|
|
Call GetArguments(objArgs)
|
|
Call DetectOSVersion()
|
|
Call GetDateTimeStamp()
|
|
Call CheckFiles()
|
|
Call InitializeAutodump()
|
|
Call RunTlist()
|
|
If IISMode = True Then
|
|
If CrashMode = True Then
|
|
Call DumpIIS(CrashDir & "\Process_List.txt", OSVer)
|
|
Else
|
|
Call DumpIIS(HangDir & "\Process_List.txt", OSVer)
|
|
End If
|
|
End If
|
|
If DumpGenericProcess = True Then
|
|
Call DumpAnyProc()
|
|
End If
|
|
Call ShowStatus(OSVer)
|
|
' ------------------------------------------------------------------------------------------
|
|
|
|
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: GetArguments
|
|
' This function is responsible for getting the arguments the user passed in on the
|
|
' command line and storing them in an array.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub GetArguments(objArgs)
|
|
On Error Resume Next
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the GetArguments() function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
Dim IsValidArgument
|
|
Dim IsValidMode, IsValidAction
|
|
Dim CallPrintHelp
|
|
Dim x, y, z
|
|
Dim Arg
|
|
Dim EnvVar
|
|
Dim Args
|
|
Dim YesNo
|
|
Dim objShell
|
|
Dim SysEnv, UserEnv, VolatileEnv
|
|
Dim Sympath
|
|
Dim objFileSystem
|
|
Dim oFS2
|
|
Dim WShNetwork
|
|
Dim CallDetectIISFromPNSwitch
|
|
|
|
Set WShNetwork = CreateObject("Wscript.Network")
|
|
Set objFileSystem = CreateObject("Scripting.FileSystemObject")
|
|
Set objShell = CreateObject("Wscript.Shell")
|
|
IsValidArgument = False
|
|
IsValidMode = False
|
|
IsValidACtion = False
|
|
x = 0
|
|
y = 0
|
|
z = 0
|
|
OutPutDir = InstallDir
|
|
ComputerName = WshNetwork.ComputerName
|
|
Args = wscript.arguments.count
|
|
If Wscript.arguments.Count > 0 Then
|
|
Set objArgs = Wscript.Arguments
|
|
For x=0 to Args-1
|
|
If UCase(objArgs(x)) = "-QUIET" Then
|
|
QuietMode = True
|
|
IsValidArgument = True
|
|
ElseIf UCase(objArgs(x)) = "-HANG" Then
|
|
HangMode = True
|
|
IsValidArgument = True
|
|
IsValidMode = True
|
|
ElseIf UCase(objArgs(x)) = "-QUICK" Then
|
|
QuickMode = True
|
|
HangMode = True
|
|
IsValidArgument = True
|
|
IsValidMode = True
|
|
ElseIf UCase(objArgs(x)) = "-CRASH" Then
|
|
CrashMode = True
|
|
HangMode = False
|
|
IsValidArgument = True
|
|
IsValidMode = True
|
|
ElseIf UCase(objArgs(x)) = "-PAGEHEAP" Then
|
|
PageHeapMode = True
|
|
IsValidArgument = True
|
|
IsValidMode = True
|
|
ElseIf UCase(objArgs(x)) = "-NOTIFY" Then
|
|
If UCase(objArgs(x+1)) = "" or UCase(objArgs(x+1)) = " " or UCase(objArgs(x+1)) = "-PN" or UCase(objArgs(x+1)) = "-O" or UCase(objArgs(x+1)) = "-P" or UCase(objArgs(x+1)) = "-HANG" or UCase(objArgs(x+1)) = "-CRASH" or UCase(objArgs(x+1)) = "-QUICK" or UCase(objArgs(x+1)) = "-IIS" or UCase(objArgs(x+1)) = "-PAGEHEAP" or UCase(objArgs(x+1)) = "-QUIET" Then
|
|
If QuietMode = False Then
|
|
objShell.PopUp "No computer name or username was specified after the '-notify' switch on the command line. If the '-notify' switch is used, the next command line argument argument must specify a valid computer name or username for AutodumpPlus to send messages to (using the Messenger Service). It is recommended that you specify a computer name as it is generally more reliable than specifying a username.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "No computer name or username was specified after the '-notify' switch on the command line. If the '-notify' switch is used, the next command line argument argument must specify a valid computer name or username for AutodumpPlus to send messages to (using the Messenger Service). It is recommended that you specify a computer name as it is generally more reliable than specifying a username."
|
|
objShell.LogEvent 1, "No computer name or username was specified after the '-notify' switch on the command line. If the '-notify' switch is used, the next command line argument argument must specify a valid computer name or username for AutodumpPlus to send messages to (using the Messenger Service). It is recommended that you specify a computer name as it is generally more reliable than specifying a username."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
wscript.quit 1
|
|
End If
|
|
NotifyTarget = objArgs(x+1)
|
|
NotifyAdmin = True
|
|
IsValidArgument = True
|
|
ElseIf UCase(objArgs(x)) = "-?" Then
|
|
CallPrintHelp = True
|
|
IsValidArgument = True
|
|
ElseIf UCase(objArgs(x)) = "-HELP" Then
|
|
CallPrintHelp = True
|
|
IsValidArgument = True
|
|
ElseIf UCase(objArgs(x)) = "-IIS" Then
|
|
IISMode = True
|
|
IsValidArgument = True
|
|
IsValidAction = True
|
|
ElseIf UCase(objArgs(x)) = "-O" Then
|
|
If UCase(objArgs(x+1)) = "" or UCase(objArgs(x+1)) = " " or UCase(objArgs(x+1)) = "-PN" or UCase(objArgs(x+1)) = "-O" or UCase(objArgs(x+1)) = "-P" or UCase(objArgs(x+1)) = "-HANG" or UCase(objArgs(x+1)) = "-CRASH" or UCase(objArgs(x+1)) = "-QUICK" or UCase(objArgs(x+1)) = "-IIS" or UCase(objArgs(x+1)) = "-PAGEHEAP" or UCase(objArgs(x+1)) = "-QUIET" Then
|
|
If QuietMode = False Then
|
|
objShell.PopUp "No valid directory or UNC path was specified after the '-o' switch. If the '-o' switch is used, the next command line argument must specify a valid path for AutodumpPlus to output files to, i.e. '-o " & Chr(34) & "\\fileserver\share" & Chr(34) & "'",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "No valid directory or UNC path was specified after the '-o' switch. If the '-o' switch is used, the next command line argument must specify a valid path for AutodumpPlus to output files to, i.e. '-o " & Chr(34) & "\\fileserver\share" & Chr(34) & "'"
|
|
objShell.LogEvent 1, "No valid directory or UNC path was specified after the '-o' switch. If the '-o' switch is used, the next command line argument must specify a valid path for AutodumpPlus to output files to, i.e. '-o " & Chr(34) & "\\fileserver\share" & Chr(34) & "'"
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
wscript.quit 1
|
|
End If
|
|
|
|
OutPutDir = objArgs(x+1)
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In GetArguments, OutPutDir = " & OutPutDir
|
|
End If
|
|
If InStr(1,OutPutDir,"\\",1) Then
|
|
OutputDir = OutPutDir & "\" & WshNetwork.ComputerName
|
|
End If
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In GetArguments, OutPutDir with server name = " & OutPutDir
|
|
End If
|
|
CreateDirectory(OutPutDir)
|
|
Set oFS2 = objFileSystem.GetFolder(OutPutDir)
|
|
OutPutDirShortPath = oFS2.ShortPath
|
|
IsValidArgument = True
|
|
OSwitchUsed = True
|
|
ElseIf UCase(objArgs(x)) = "-P" Then
|
|
If UCase(objArgs(x+1)) = "" or UCase(objArgs(x+1)) = " " or UCase(objArgs(x+1)) = "-PN" or UCase(objArgs(x+1)) = "-O" or UCase(objArgs(x+1)) = "-P" Then
|
|
If QuietMode = False Then
|
|
objShell.PopUp "If the '-p' switch is used, you must specify the PID (Process ID) of a process to attach to, i.e. '-p 1896'",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "If the '-p' switch is used, you must specify the PID (Process ID) of a process to attach to, i.e. '-p 1896'"
|
|
objShell.LogEvent 1, "If the '-p' switch is used, you must specify the PID (Process ID) of a process to attach to, i.e. '-p 1896'"
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
wscript.quit 1
|
|
End If
|
|
|
|
GenericProcessPIDDictionary.add y, objArgs(x+1)
|
|
y = y+1
|
|
DumpGenericProcess = True
|
|
GenericModePID = True
|
|
IsValidArgument = True
|
|
IsValidAction = True
|
|
ElseIf UCase(objArgs(x)) = "-PN" Then
|
|
If UCase(objArgs(x+1)) = "" or UCase(objArgs(x+1)) = " " or UCase(objArgs(x+1)) = "-P" or UCase(objArgs(x+1)) = "-O" or UCase(objArgs(x+1)) = "-PN" Then
|
|
If QuietMode = False Then
|
|
objShell.PopUp "If the '-pn' switch is used, you must specify the name of a process to attach to, i.e. '-pn mmc.exe'",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "If the '-pn' switch is used, you must specify the name of a process to attach to, i.e. '-pn mmc.exe'"
|
|
objShell.LogEvent 1, "If the '-pn' switch is used, you must specify the name of a process to attach to, i.e. '-pn mmc.exe'"
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
wscript.quit 1
|
|
End If
|
|
|
|
GenericProcessNameDictionary.add z, objArgs(x+1)
|
|
z = z+1
|
|
DumpGenericProcess = True
|
|
GenericModeProcessName = True
|
|
IsValidArgument = True
|
|
IsValidAction = True
|
|
|
|
End If
|
|
|
|
Next
|
|
|
|
Else 'No arguments were typed, display the usage info . . .
|
|
'After getting the arguments, the first thing we need to do is determine the script engine that is running AutodumpPlus.
|
|
Call DetectScriptEngine()
|
|
Call PrintUsage()
|
|
End If
|
|
|
|
'Check to see if PageHeapMode is being used in Crash mode or hang mode. If used in hang mode, display an error and quit.
|
|
If PageHeapMode = True and CrashMode = False Then
|
|
If QuietMode = False Then
|
|
objShell.PopUp "AutodumpPlus must be running in crash mode ('-crash' switch) in order to use the '-pageheap' switch. Please re-run AutodumpPlus using the '-crash' switch if you are trying to use Pageheap to troubleshoot heap corruption.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "AutodumpPlus must be running in crash mode ('-crash' switch) in order to use the '-pageheap' switch. Please re-run AutodumpPlus using the '-crash' switch if you are trying to use Pageheap to troubleshoot heap corruption."
|
|
objShell.LogEvent 1, "AutodumpPlus must be running in crash mode ('-crash' switch) in order to use the '-pageheap' switch. Please re-run AutodumpPlus using the '-crash' switch if you are trying to use Pageheap to troubleshoot heap corruption."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
wscript.quit 1
|
|
End If
|
|
|
|
'Check to see if the -notify switch is being used in 'Hang' mode, if so display an error.
|
|
If NotifyAdmin = True and HangMode = True Then
|
|
If QuietMode = False Then
|
|
objShell.PopUp "The '-notify' switch is only valid when running in crash mode. Please try running AutodumpPlus again in 'crash' mode or without the '-notify' switch.",,"AutodumpPlus",0
|
|
ErrorsDuringRuntime = True
|
|
wscript.quit 1
|
|
Else
|
|
Wscript.echo "The '-notify' switch is only valid when running in crash mode. Please try running AutodumpPlus again in 'crash' mode or without the '-notify' switch."
|
|
objShell.LogEvent 1, "The '-notify' switch is only valid when running in crash mode. Please try running AutodumpPlus again in 'crash' mode or without the '-notify' switch."
|
|
ErrorsDuringRuntime = True
|
|
wscript.quit 1
|
|
End If
|
|
End If
|
|
|
|
'After getting the arguments, the first thing we need to do is determine the script engine that is running AutodumpPlus.
|
|
Call DetectScriptEngine()
|
|
|
|
'Check to see whether the '-iis' switch was used along with the '-pn' switch for any duplicate process dumping / monitoring
|
|
'objShell.Popup "Debug Break", 0
|
|
For Arg = 0 to objArgs.Count -1
|
|
If IISMode = True Then
|
|
DetectIISVersion()
|
|
End If
|
|
If IISMode = True and UCase(objArgs(Arg)) = "DLLHOST.EXE" Then
|
|
If HangMode = True or QuickMode = True Then
|
|
If QuietMode = False Then
|
|
objShell.Popup "You have specified the '-iis' switch on the command line in addition to '-pn dllhost.exe'. The '-iis' switch when used in 'hang' or 'quick' mode will automatically dump all running instances of dllhost.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to dump the System package, please use the '-p' switch and specify the PID for the System package.",,"Autodump",0
|
|
Wscript.quit 1
|
|
Else
|
|
wscript.echo "You have specified the '-iis' switch on the command line in addition to '-pn dllhost.exe'. The '-iis' switch when used in 'hang' or 'quick' mode will automatically dump all running instances of dllhost.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to dump the System package, please use the '-p' switch and specify the PID for the System package."
|
|
objShell.logevent 1, "You have specified the '-iis' switch on the command line in addition to '-pn dllhost.exe'. The '-iis' switch when used in 'hang' or 'quick' mode will automatically dump all running instances of dllhost.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to dump the System package, please use the '-p' switch and specify the PID for the System package."
|
|
Wscript.quit 1
|
|
End If
|
|
Else
|
|
If QuietMode = False Then
|
|
objShell.Popup "You have specified the '-iis' switch on the command line in addition to '-pn dllhost.exe'. The '-iis' switch when used in 'crash' mode will automatically attach a debugger to all running instances of dllhost.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to attach a debugger to the System package, please use the '-p' switch and specify the PID for the System package.",,"Autodump",0
|
|
Wscript.quit 1
|
|
Else
|
|
wscript.echo "You have specified the '-iis' switch on the command line in addition to '-pn dllhost.exe'. The '-iis' switch when used in 'crash' mode will automatically attach a debugger to all running instances of dllhost.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to attach a debugger to the System package, please use the '-p' switch and specify the PID for the System package."
|
|
objShell.logevent 1, "You have specified the '-iis' switch on the command line in addition to '-pn dllhost.exe'. The '-iis' switch when used in 'crash' mode will automatically attach a debugger to all running instances of dllhost.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to attach a debugger to the System package, please use the '-p' switch and specify the PID for the System package."
|
|
Wscript.quit 1
|
|
End If
|
|
End If
|
|
ElseIf IISMode = True and UCase(objArgs(Arg)) = "MTX.EXE" Then
|
|
If HangMode = True or QuickMode = True Then
|
|
If QuietMode = False Then
|
|
objShell.Popup "You have specified the '-iis' switch on the command line in addition to '-pn mtx.exe'. The '-iis' switch when used in 'hang' or 'quick' mode will automatically dump all running instances of mtx.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to dump the System package, please use the '-p' switch and specify the PID for the System package.",,"Autodump",0
|
|
Wscript.quit 1
|
|
Else
|
|
wscript.echo "You have specified the '-iis' switch on the command line in addition to '-pn mtx.exe'. The '-iis' switch when used in 'hang' or 'quick' mode will automatically dump all running instances of mtx.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to dump the System package, please use the '-p' switch and specify the PID for the System package."
|
|
objShell.logevent 1, "You have specified the '-iis' switch on the command line in addition to '-pn mtx.exe'. The '-iis' switch when used in 'hang' or 'quick' mode will automatically dump all running instances of mtx.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to dump the System package, please use the '-p' switch and specify the PID for the System package."
|
|
Wscript.quit 1
|
|
End If
|
|
Else
|
|
If QuietMode = False Then
|
|
objShell.Popup "You have specified the '-iis' switch on the command line in addition to '-pn mtx.exe'. The '-iis' switch when used in 'crash' mode will automatically attach a debugger to all running instances of mtx.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to attach a debugger to the System package, please use the '-p' switch and specify the PID for the System package.",,"Autodump",0
|
|
Wscript.quit 1
|
|
Else
|
|
wscript.echo "You have specified the '-iis' switch on the command line in addition to '-pn mtx.exe'. The '-iis' switch when used in 'crash' mode will automatically attach a debugger to all running instances of mtx.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to attach a debugger to the System package, please use the '-p' switch and specify the PID for the System package."
|
|
objShell.logevent 1, "You have specified the '-iis' switch on the command line in addition to '-pn mtx.exe'. The '-iis' switch when used in 'crash' mode will automatically attach a debugger to all running instances of mtx.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to attach a debugger to the System package, please use the '-p' switch and specify the PID for the System package."
|
|
Wscript.quit 1
|
|
End If
|
|
End If
|
|
ElseIf IISMode = True and UCase(objArgs(Arg)) = "INETINFO.EXE" Then
|
|
If HangMode = True or QuickMode = True Then
|
|
If QuietMode = False Then
|
|
objShell.Popup "You have specified the '-iis' switch on the command line in addition to '-pn inetinfo.exe'. The '-iis' switch when used in 'hang' or 'quick' mode will automatically dump all running instances of inetinfo.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to dump the System package, please use the '-p' switch and specify the PID for the System package.",,"Autodump",0
|
|
Wscript.quit 1
|
|
Else
|
|
wscript.echo "You have specified the '-iis' switch on the command line in addition to '-pn inetinfo.exe'. The '-iis' switch when used in 'hang' or 'quick' mode will automatically dump all running instances of inetinfo.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to dump the System package, please use the '-p' switch and specify the PID for the System package."
|
|
objShell.logevent 1, "You have specified the '-iis' switch on the command line in addition to '-pn inetinfo.exe'. The '-iis' switch when used in 'hang' or 'quick' mode will automatically dump all running instances of inetinfo.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to dump the System package, please use the '-p' switch and specify the PID for the System package."
|
|
Wscript.quit 1
|
|
End If
|
|
Else
|
|
If QuietMode = False Then
|
|
objShell.Popup "You have specified the '-iis' switch on the command line in addition to '-pn inetinfo.exe'. The '-iis' switch when used in 'crash' mode will automatically attach a debugger to all running instances of inetinfo.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to attach a debugger to the System package, please use the '-p' switch and specify the PID for the System package.",,"Autodump",0
|
|
Wscript.quit 1
|
|
Else
|
|
wscript.echo "You have specified the '-iis' switch on the command line in addition to '-pn inetinfo.exe'. The '-iis' switch when used in 'crash' mode will automatically attach a debugger to all running instances of inetinfo.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to attach a debugger to the System package, please use the '-p' switch and specify the PID for the System package."
|
|
objShell.logevent 1, "You have specified the '-iis' switch on the command line in addition to '-pn inetinfo.exe'. The '-iis' switch when used in 'crash' mode will automatically attach a debugger to all running instances of inetinfo.exe. Please run AutodumpPlus again without the '-pn' switch. If you are trying to attach a debugger to the System package, please use the '-p' switch and specify the PID for the System package."
|
|
Wscript.quit 1
|
|
End If
|
|
End If
|
|
End If
|
|
Next
|
|
|
|
|
|
'Check to see if we need to print the help screen
|
|
If CallPrintHelp = True Then
|
|
PrintHelp()
|
|
End If
|
|
|
|
If IsValidArgument = False Then 'No valid arguments were passed in, display the usage info . . .
|
|
Call PrintUsage()
|
|
QuickMode = False
|
|
QuietMode = False
|
|
CrashMode = False
|
|
End If
|
|
|
|
If not (IsValidMode and IsValidAction) Then
|
|
PrintUsage()
|
|
End If
|
|
|
|
|
|
If HangMode = True AND CrashMode = True Then 'Can't run in both hang and crash mode at the same time
|
|
Call PrintUsage()
|
|
ElseIf CrashMode = True AND QuickMode = True Then 'Can't run in both crash and quick mode at the same time
|
|
Call PrintUsage()
|
|
ElseIf HangMode <> True and CrashMode <> True and QuickMode <> True Then 'You have to at least be running in hang, crash, or quick mode
|
|
Call PrintUsage()
|
|
End If
|
|
|
|
|
|
Set SysEnv = objShell.Environment("SYSTEM")
|
|
Set UserEnv = objShell.Environment("USER")
|
|
If QuickMode = True or CrashMode = True Then
|
|
If SysEnv("_NT_SYMBOL_PATH") <> "" Then
|
|
Sympath = SysEnv("_NT_SYMBOL_PATH")
|
|
ElseIf UserEnv("_NT_SYMBOL_PATH") <> "" Then
|
|
Sympath = UserEnv("_NT_SYMBOL_PATH")
|
|
Else
|
|
If QuietMode = False Then
|
|
objShell.Popup "WARNING! An '_NT_SYMBOL_PATH' environment variable is not set, as a result AutodumpPlus will be forced to use 'export' symbols (if present) to resolve function names in the stack trace information for each thread listed in the log file for the processes being debugged. To resolve this warning, please copy the appropriate symbols to a directory on the server and then create an environment variable with a name of '_NT_SYMBOL_PATH' and a value containing the path to the proper symbols (i.e. c:\winnt\symbols) before running AutodumpPlus in quick or crash modes again. NOTE: After creating the '_NT_SYMBOL_PATH' system environment variable you will need to close the current command shell and open a new one before running AutodumpPlus again.",,"AutodumpPlus",0
|
|
SymPathError = True
|
|
ErrorsDuringScriptRuntime = True
|
|
Else
|
|
Wscript.echo "WARNING! An '_NT_SYMBOL_PATH' environment variable is not set."
|
|
Wscript.echo "Please check the application event log or the AutodumpPlus-report.txt"
|
|
Wscript.echo "for more details."
|
|
Wscript.echo ""
|
|
objShell.LogEvent 1, "WARNING! An '_NT_SYMBOL_PATH' environment variable is not set, as a result AutodumpPlus will be forced to use 'export' symbols (if present) to resolve function names in the stack trace information for each thread listed in the log file for the processes being debugged. To resolve this warning, please copy the appropriate symbols to a directory on the server and then create an environment variable with a name of '_NT_SYMBOL_PATH' and a value containing the path to the proper symbols (i.e. c:\winnt\symbols) before running AutodumpPlus in quick or crash modes again. NOTE: After creating the '_NT_SYMBOL_PATH' system environment variable you will need to close the current command shell and open a new one before running AutodumpPlus again."
|
|
SymPathError = True
|
|
End If
|
|
'Wscript.Quit
|
|
End If
|
|
|
|
End If
|
|
|
|
'If not running on Windows XP, check to see if the user account is running inside of a terminal server session.
|
|
'If so, and the -crash switch is being used, display an error since 'crash' mode doesn't work inside of a terminal
|
|
'server session on NT 4.0 or Windows 2000.
|
|
'If the server doesn't have terminal services installed, we can assume they aren't running ADPlus in a TS session
|
|
'so check for that first.
|
|
'I have not tested this on NT 4.0 TSE so I'm not sure if this code will work properly on NT 4.0 TSE boxes.
|
|
|
|
Call DetectOSVersion
|
|
If CInt(OSBuildNumber) <= 2195 Then
|
|
Dim TermServDeviceDesc
|
|
Dim TermServKey
|
|
TermServKey = "HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum\Root\RDPDR\0000\DeviceDesc"
|
|
err.clear
|
|
TermServDeviceDesc = objShell.RegRead(TermServKey)
|
|
If err.number <> -2147024894 Then 'The TS RDPDR key was found, Terminal services is installed, check to make sure the user isn't in a TS session.
|
|
Set VolatileEnv = objShell.Environment("PROCESS")
|
|
|
|
If (UCase(VolatileEnv("SESSIONNAME")) <> "CONSOLE" and VolatileEnv("SESSIONNAME") <> "") and (CrashMode = True) Then
|
|
If QuietMode = False Then
|
|
objShell.Popup "AutodumpPlus has detected that you are attempting to run in 'Crash' mode, but this account is currently logged into terminal server session ID: " & UCase(VolatileEnv("SESSIONNAME")) & ". 'Crash' mode (invoked via the '-crash' switch) will not work inside a terminal server session. To run AutodumpPlus in 'Crash' mode, please log in locally at the console.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "AutodumpPlus has detected that you are attempting to run in 'Crash' mode, but this account is currently logged into terminal server session ID: " & UCase(VolatileEnv("SESSIONNAME")) & ". 'Crash' mode (invoked via the '-crash' switch) will not work inside a terminal server session. To run AutodumpPlus in 'Crash' mode, please log in locally at the console."
|
|
objShell.LogEvent 1, "AutodumpPlus has detected that you are attempting to run in 'Crash' mode, but this account is currently logged into terminal server session ID: " & UCase(VolatileEnv("SESSIONNAME")) & ". 'Crash' mode (invoked via the '-crash' switch) will not work inside a terminal server session. To run AutodumpPlus in 'Crash' mode, please log in locally at the console."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
Wscript.Quit
|
|
End If
|
|
End If
|
|
End If
|
|
|
|
'Get the locally logged on users name for use with the !Net_send command
|
|
LocalUserName = VolatileEnv("USERNAME")
|
|
|
|
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "--------------------------------"
|
|
wscript.echo "In GetArguments(), QuickMode = " & QuickMode
|
|
wscript.echo "In GetArguments(), QuietMode = " & QuietMode
|
|
wscript.echo "In GetArguments(), CrashMode = " & CrashMode
|
|
wscript.echo "In GetArguments(), HangMode = " & HangMode
|
|
wscript.echo "In GetArguments(), LocaluserName = " & LocalUserName
|
|
wscript.echo "--------------------------------"
|
|
End If
|
|
|
|
End Sub
|
|
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: GetDateTimeStamp
|
|
' This function is responsible for getting the unique Date / Time stamp used for
|
|
' creating unique directory / file names.
|
|
' To Change the names of the output directories, edit them below.
|
|
'---------------------------------------------------------------------------------------------
|
|
Function GetDateTimeStamp()
|
|
On Error Resume Next
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the GetDateTimeStamp() function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
Dim AMorPM
|
|
Dim Seconds
|
|
Dim Minutes
|
|
Dim Hours
|
|
Dim theDay
|
|
Dim theMonth
|
|
Hours = Hour(Now)
|
|
Minutes = Minute(Now)
|
|
Seconds = Second(Now)
|
|
theDay = Day(Now)
|
|
theMonth = Month(Now)
|
|
AMorPM = Right(Now(),2)
|
|
|
|
If Len(Hours) = 1 Then Hours = "0" & Hours
|
|
If Len(Minutes) = 1 Then Minutes = "0" & Minutes
|
|
If Len(Seconds) = 1 Then Seconds = "0" & Seconds
|
|
If Len(theDay) = 1 Then theDay = "0" & theDay
|
|
If Len(theMonth) = 1 Then theMonth = "0" & theMonth
|
|
|
|
DateTimeStamp = "Date_" & theMonth & "-" & theDay & "-" & Year(Now) & "__Time_" & Hours & "-" & Minutes & "-" & Seconds & AMorPM
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In GetDateTimeStamp(), DateTimeStamp = " & DateTimeStamp
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
|
|
If QuickMode = True Then
|
|
HangDir = OutPutDir & "\Quick_Hang_Mode__" + DateTimeStamp
|
|
|
|
Else
|
|
HangDir = OutPutDir & "\Normal_Hang_Mode__" + DateTimeStamp
|
|
CrashDir = OutPutDir + "\Crash_Mode__" + DateTimeStamp
|
|
End If
|
|
|
|
End Function
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: CheckFiles
|
|
' This function is responsible for ensuring that all the required files are
|
|
' installed in the 'InstallDir'. If files are missing, display an error or
|
|
' log an error to the event log if running in quiet mode.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub CheckFiles()
|
|
On Error Resume Next
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the CheckFiles() function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
Dim objFS
|
|
Dim objShell
|
|
Set objFS = CreateObject("Scripting.FileSystemObject")
|
|
Set objShell = CreateObject("Wscript.Shell")
|
|
|
|
'Make sure CDB.EXE & ADPlus.vbs are in the right place. If its not it could mean ADPlus.vbs isn't running from the debuggers directory.
|
|
If not FileExists(InstallDir & "\cdb.exe") Then
|
|
If QuietMode = False Then
|
|
objShell.popup "AutodumpPlus is not configured properly. Either the file CDB.EXE is missing from " & InstallDir & " or ADPlus.vbs is not running from the debuggers installation directory. Please place ADPlus.vbs in the debuggers installation directory or try re-installing the Debugging Tools for Windows.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus is not configured properly. Either the file CDB.EXE is missing from " & InstallDir & " or ADPlus.vbs is not running from the debuggers installation directory. Please place ADPlus.vbs in the debuggers installation directory or try re-installing the Debugging Tools for Windows."
|
|
wscript.echo "AutodumpPlus is not configured properly. Either the file CDB.EXE is missing from " & InstallDir & " or ADPlus.vbs is not running from the debuggers installation directory. Please place ADPlus.vbs in the debuggers installation directory or try re-installing the Debugging Tools for Windows."
|
|
End If
|
|
wscript.quit 1
|
|
End If
|
|
|
|
|
|
'Make sure the NT 4.0 debug extensions are installed
|
|
If OSVer = "4.0" Then
|
|
If not FileExists(InstallDir & "\nt4fre\userexts.dll") Then
|
|
If QuietMode = False Then
|
|
objShell.popup "AutodumpPlus is not configured properly. The file userexts.dll is missing from " & InstallDir & "\nt4fre" & ". Please re-install the Debugging Tools for Windows.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus is not configured properly. The file userexts.dll is missing from " & InstallDir & "\nt4fre" & ". Please re-install the Debugging Tools for Windows."
|
|
wscript.echo "AutodumpPlus is not configured properly. The file userexts.dll is missing from " & InstallDir & "\nt4fre" & ". Please re-install the Debugging Tools for Windows."
|
|
End If
|
|
wscript.quit 1
|
|
End If
|
|
End If
|
|
|
|
'Make sure the Windows 2000 debug extensions are installed
|
|
If CInt(OSBuildNumber) = 2195 Then
|
|
If not FileExists(InstallDir & "\w2kfre\userexts.dll") Then
|
|
If QuietMode = False Then
|
|
objShell.popup "AutodumpPlus is not configured properly. The file userexts.dll is missing from " & InstallDir & "\w2kfre" & ". Please re-install the Debugging Tools for Windows.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus is not configured properly. The file userexts.dll is missing from " & InstallDir & "\w2kfre" & ". Please re-install the Debugging Tools for Windows."
|
|
wscript.echo "AutodumpPlus is not configured properly. The file userexts.dll is missing from " & InstallDir & "\w2kfre" & ". Please re-install the Debugging Tools for Windows."
|
|
End If
|
|
wscript.quit 1
|
|
End If
|
|
End If
|
|
|
|
'Make sure the Windows XP debug extensions are installed
|
|
'If CInt(OSBuildNumber) > 2195 Then
|
|
' If not FileExists(InstallDir & "\w2001\userexts.dll") Then
|
|
' If QuietMode = False Then
|
|
' objShell.popup "AutodumpPlus is not configured properly. The file userexts.dll is missing from " & InstallDir & "\winxp" & ". Please re-install the Debugging Tools for Windows.",,"AutodumpPlus",0
|
|
' Else
|
|
' objShell.LogEvent 1, "AutodumpPlus is not configured properly. The file userexts.dll is missing from " & InstallDir & "\winxp" & ". Please re-install the Debugging Tools for Windows."
|
|
' wscript.echo "AutodumpPlus is not configured properly. The file userexts.dll is missing from " & InstallDir & "\winxp" & ". Please re-install the Debugging Tools for Windows."
|
|
' End If
|
|
' wscript.quit 1
|
|
' End If
|
|
'End If
|
|
|
|
|
|
If not FileExists(InstallDir & "\cdb.exe") then
|
|
If QuietMode = False Then
|
|
objShell.popup "AutodumpPlus is not configured properly. The file cdb.exe is missing from " & InstallDir & ". Please re-install the Debugging Tools for Windows.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus is not configured properly. The file cdb.exe is missing from " & InstallDir & ". Please re-install the Debugging Tools for Windows."
|
|
wscript.echo "AutodumpPlus is not configured properly. The file cdb.exe is missing from " & InstallDir & ". Please re-install the Debugging Tools for Windows."
|
|
End If
|
|
wscript.quit 1
|
|
end If
|
|
|
|
If not FileExists(InstallDir & "\dbgeng.dll") Then
|
|
If QuietMode = False Then
|
|
objShell.popup "AutodumpPlus is not configured properly. The file dbgeng.dll is missing from " & InstallDir & ". Please re-install the Debugging Tools for Windows.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus is not configured properly. The file dbgeng.dll is missing from " & InstallDir & ". Please re-install the Debugging Tools for Windows."
|
|
wscript.echo "AutodumpPlus is not configured properly. The file dbgeng.dll is missing from " & InstallDir & ". Please re-install the Debugging Tools for Windows."
|
|
End If
|
|
wscript.quit 1
|
|
end If
|
|
|
|
If not FileExists(InstallDir & "\dbghelp.dll") then
|
|
If QuietMode = False Then
|
|
objShell.popup "AutodumpPlus is not configured properly. The file dbghelp.dll is missing from " & InstallDir & ". Please re-install the Debugging Tools for Windows.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus is not configured properly. The file dbghelp.dll is missing from " & InstallDir & ". Please re-install the Debugging Tools for Windows."
|
|
wscript.echo "AutodumpPlus is not configured properly. The file dbghelp.dll is missing from " & InstallDir & ". Please re-install the Debugging Tools for Windows."
|
|
End If
|
|
wscript.quit 1
|
|
end If
|
|
|
|
If not FileExists(InstallDir & "\tlist.exe") then
|
|
If QuietMode = False Then
|
|
objShell.popup "AutodumpPlus is not configured properly. The file tlist.exe is missing from " & InstallDir & ". Please re-install the Debugging Tools for Windows.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus is not configured properly. The file tlist.exe is missing from " & InstallDir & ". Please re-install the Debugging Tools for Windows."
|
|
wscript.echo "AutodumpPlus is not configured properly. The file tlist.exe is missing from " & InstallDir & ". Please re-install the Debugging Tools for Windows."
|
|
End If
|
|
wscript.quit 1
|
|
end If
|
|
|
|
set objFS= nothing
|
|
set objShell = nothing
|
|
|
|
End Sub
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: InitializeAutodump
|
|
' This function is responsible for creating the crash or hang directories.
|
|
' The CreateDirectory function is called from this function and handles any
|
|
' permissions / directory creation problems by displaying an error or logging to
|
|
' the event log if running in quiet mode.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub InitializeAutodump()
|
|
On Error Resume Next
|
|
|
|
Dim versionFile
|
|
Dim objFileSystem
|
|
Dim oFSHang
|
|
Dim oFSCrash
|
|
On Error Resume Next
|
|
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "-----------------------"
|
|
wscript.echo "In InitializeAutodump"
|
|
wscript.echo "-----------------------"
|
|
End If
|
|
|
|
set objFileSystem = CreateObject("Scripting.FileSystemObject")
|
|
Set objShell = CreateObject("Wscript.Shell")
|
|
|
|
|
|
If CrashMode = true Then
|
|
If Create_Full_Dump_on_1st_Chance_Exception = TRUE and No_Dump_on_1st_Chance_Exception = TRUE Then
|
|
If QuietMode = False Then
|
|
objShell.popup "AutodumpPlus is not configured properly. The following constants: Create_Full_Dump_on_1st_Chance_Exception and No_Dump_on_1st_Chance_Exception are both set to TRUE and this is mutually exclusive behavior. Please set one or both of those constants to FALSE and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus is not configured properly. The following constants: Create_Full_Dump_on_1st_Chance_Exception and No_Dump_on_1st_Chance_Exception are both set to TRUE and this is mutually exclusive behavior. Please set one or both of those constants to FALSE and try running AutodumpPlus again."
|
|
wscript.echo "AutodumpPlus is not configured properly. The following constants: Create_Full_Dump_on_1st_Chance_Exception and No_Dump_on_1st_Chance_Exception are both set to TRUE and this is mutually exclusive behavior. Please set one or both of those constants to FALSE and try running AutodumpPlus again."
|
|
End If
|
|
wscript.quit 1
|
|
End If
|
|
|
|
Call CreateDirectory(CrashDir) ' Create the new crash mode folder.
|
|
Set oFSCrash = objFileSystem.GetFolder(CrashDir)
|
|
ShortCrashDir = oFSCrash.ShortPath 'Set the short file name.
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In InitializeAutodump(), CrashDir = " & CrashDir
|
|
wscript.echo "In InitializeAutodump(), ShortCrashDir = " & ShortCrashDir
|
|
Wscript.echo "Error number after calling oFSCrash.Shortpath = " & err.number
|
|
Wscript.echo "Error description: " & err.description
|
|
wscript.echo " ------------------------------------------------------------"
|
|
If ShortCrashDir = "" Then
|
|
Wscript.quit 1
|
|
End If
|
|
End If
|
|
|
|
If ShortCrashDir = "" Then
|
|
If QuietMode = False Then
|
|
objShell.Popup "AutodumpPlus encountered an error trying to get the short path name for the following directory: " & CrashDir & ". AutodumpPlus can not continue.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus encountered an error trying to get the short path name for the following directory: " & CrashDir & ". AutodumpPlus can not continue."
|
|
wscript.echo "AutodumpPlus encountered an error trying to get the short path name for the following directory: " & CrashDir & ". AutodumpPlus can not continue."
|
|
End If
|
|
DeleteDirectory(CrashDir)
|
|
Wscript.quit 1
|
|
End If
|
|
|
|
Else
|
|
Call CreateDirectory(HangDir) ' Create the new hang mode folder.
|
|
Set oFSHang = objFileSystem.GetFolder(HangDir)
|
|
ShortHangDir = oFSHang.ShortPath 'Set the short file name.
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In InitializeAutodump(), HangDir = " & HangDir
|
|
wscript.echo "In InitializeAutodump(), ShortHangDir = " & ShortHangDir
|
|
Wscript.echo "Error number after calling oFSHang.Shortpath = " & err.number
|
|
Wscript.echo "Error description: " & err.description
|
|
wscript.echo " ------------------------------------------------------------"
|
|
If ShortHangDir = "" Then
|
|
Wscript.quit 1
|
|
End If
|
|
End If
|
|
|
|
If ShortHangDir = "" Then
|
|
If QuietMode = False Then
|
|
objShell.Popup "AutodumpPlus encountered an error trying to get the short path name for the following directory: " & HangDir & ". AutodumpPlus can not continue.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus encountered an error trying to get the short path name for the following directory: " & HangDir & ". AutodumpPlus can not continue."
|
|
wscript.echo "AutodumpPlus encountered an error trying to get the short path name for the following directory: " & HangDir & ". AutodumpPlus can not continue."
|
|
End If
|
|
DeleteDirectory(HangDir)
|
|
Wscript.quit 1
|
|
End If
|
|
|
|
End If
|
|
|
|
End Sub
|
|
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: RunTlist
|
|
' This function is responsible for running tlist.exe -k to get a list of all
|
|
' running MTS or COM+ packages and piping it out to the appropriate text file.
|
|
' This function also runs EMCMD.EXE /T to get a list of all running processes.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub RunTlist()
|
|
On Error Resume Next
|
|
|
|
Dim objShell
|
|
Dim objFileSystem
|
|
Dim oFS2
|
|
Dim objTextFile
|
|
Dim strShell
|
|
Dim objShellErrorLevel
|
|
Dim DriveObject
|
|
Dim Path
|
|
Dim NewPath
|
|
Dim PathArray
|
|
Dim ServerName
|
|
Dim ShareName
|
|
Dim MinFreeSpace
|
|
|
|
|
|
Set objShell = CreateObject("Wscript.Shell")
|
|
Set objFileSystem = CreateObject("Scripting.FileSystemObject")
|
|
MinFreeSpace = 10000000 '10Mb free space should be enough to at least produce the .txt files and the output logs.
|
|
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "-----------------------"
|
|
wscript.echo "In RunTlist"
|
|
wscript.echo ""
|
|
End If
|
|
|
|
|
|
'Check the output directories drive to ensure there is enough free space for the files.
|
|
If CrashMode = true Then
|
|
If Left(ShortCrashDir,2) <> "\\" Then 'We are in crash mode but not logging to a UNC path.
|
|
Set DriveObject = objFileSystem.GetDrive(Left(ShortCrashDir,1))
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In RunTlist(), Err number after calling objFileSystem.GetDrive: " & err.number & " Err Description: " & err.description
|
|
Wscript.echo "In RunTlist(), Free space = " & DriveObject.FreeSpace
|
|
Wscript.echo "In RunTlist(), MinFreeSpace = " & MinFreeSpace
|
|
Wscript.echo ""
|
|
End If
|
|
If No_Free_Space_Checking = False Then
|
|
If DriveObject.FreeSpace < MinFreeSpace Then
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In RunEcmdm(), No_Free_Space_Checking = FALSE"
|
|
Wscript.echo "In RunTlist(), Err number after calling DriveObject.Freespace: " & err.number & " Err Description: " & err.description
|
|
Wscript.echo "In RunTlist(), Free space = " & DriveObject.FreeSpace
|
|
Wscript.echo "In RunTlist(), MinFreeSpace = " & MinFreeSpace
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
If QuietMode = False Then
|
|
objShell.popup "AutodumpPlus has detected that there is not enough free space on the " & Left(ShortCrashDir,2) & " drive. AutodumpPlus requires at least 10Mb of free space. Please free up some space on that drive and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus has detected that there is not enough free space on the " & Left(ShortCrashDir,2) & " drive. AutodumpPlus requires at least 10Mb of free space. Please free up some space on that drive and try running AutodumpPlus again."
|
|
wscript.echo "AutodumpPlus has detected that there is not enough free space on the " & Left(ShortCrashDir,2) & " drive. AutodumpPlus requires at least 10Mb of free space. Please free up some space on that drive and try running AutodumpPlus again."
|
|
End If
|
|
DeleteDirectory(ShortCrashDir)
|
|
wscript.quit 1
|
|
End If
|
|
Else
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In RunTlist(), No_Free_Space_Checking = TRUE"
|
|
Wscript.echo "In RunTlist(), Call to DriveObject.Freespace skipped!"
|
|
Wscript.echo "In RunTlist(), Err number after calling objFileSystem.GetDrive: " & err.number & " Err Description: " & err.description
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
End If
|
|
|
|
Else 'We are in crash mode and logging to a UNC path
|
|
Path = ShortCrashDir
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "Path = " & Path
|
|
End If
|
|
NewPath = Right(Path, Len(Path) - 2)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "NewPath = " & NewPath
|
|
End If
|
|
PathArray = Split(NewPath, "\", -1)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "ServerName = " & PathArray(0)
|
|
End If
|
|
ServerName = PathArray(0)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "ShareName = " & PathArray(1)
|
|
End If
|
|
ShareName = PathArray(1)
|
|
NewPath = "\\" & ServerName & "\" & ShareName
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "NewPath = " & NewPath
|
|
End If
|
|
Set DriveObject = objFileSystem.GetDrive(NewPath)
|
|
|
|
|
|
If No_Free_Space_Checking = False Then
|
|
If DriveObject.FreeSpace < MinFreeSpace Then
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In RunEcmdm(), No_Free_Space_Checking = FALSE"
|
|
Wscript.echo "In RunTlist(), Err number after calling DriveObject.Freespace: " & err.number & " Err Description: " & err.description
|
|
Wscript.echo "In RunTlist(), Free space = " & DriveObject.FreeSpace
|
|
Wscript.echo "In RunTlist(), MinFreeSpace = " & MinFreeSpace
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
If QuietMode = False Then
|
|
objShell.popup "AutodumpPlus has detected that there is not enough free space on the following network share " & CrashDir & ". AutodumpPlus requires at least 10Mb of free space. Please free up some space on that drive and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus has detected that there is not enough free space on the following network share " & CrashDir & ". AutodumpPlus requires at least 10Mb of free space. Please free up some space on that drive and try running AutodumpPlus again."
|
|
wscript.echo "AutodumpPlus has detected that there is not enough free space on the following network share " & CrashDir & ". AutodumpPlus requires at least 10Mb of free space. Please free up some space on that drive and try running AutodumpPlus again."
|
|
End If
|
|
DeleteDirectory(ShortCrashDir)
|
|
wscript.quit 1
|
|
End If
|
|
Else
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In RunTlist(), No_Free_Space_Checking = TRUE"
|
|
Wscript.echo "In RunTlist(), Call to DriveObject.Freespace skipped!"
|
|
Wscript.echo "In RunTlist(), Err number after calling objFileSystem.GetDrive: " & err.number & " Err Description: " & err.description
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
End If
|
|
|
|
|
|
End If
|
|
Else 'We are in hang mode
|
|
If Left(ShortHangDir,2) <> "\\" Then 'We are in hang mode but not logging to a UNC path
|
|
Set DriveObject = objFileSystem.GetDrive(Left(ShortHangDir,1))
|
|
If No_Free_Space_Checking = False Then
|
|
If DriveObject.FreeSpace < MinFreeSpace Then
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In RunEcmdm(), No_Free_Space_Checking = FALSE"
|
|
Wscript.echo "In RunTlist(), Err number after calling DriveObject.Freespace: " & err.number & " Err Description: " & err.description
|
|
Wscript.echo "In RunTlist(), Free space = " & DriveObject.FreeSpace
|
|
Wscript.echo "In RunTlist(), MinFreeSpace = " & MinFreeSpace
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
If QuietMode = False Then
|
|
objShell.popup "AutodumpPlus has detected that there is not enough free space on the " & Left(ShortCrashDir,2) & " drive. AutodumpPlus requires at least 10Mb of free space. Please free up some space on that drive and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus has detected that there is not enough free space on the " & Left(ShortCrashDir,2) & " drive. AutodumpPlus requires at least 10Mb of free space. Please free up some space on that drive and try running AutodumpPlus again."
|
|
wscript.echo "AutodumpPlus has detected that there is not enough free space on the " & Left(ShortCrashDir,2) & " drive. AutodumpPlus requires at least 10Mb of free space. Please free up some space on that drive and try running AutodumpPlus again."
|
|
End If
|
|
DeleteDirectory(ShortHangDir)
|
|
wscript.quit 1
|
|
End If
|
|
Else
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In RunTlist(), No_Free_Space_Checking = TRUE"
|
|
Wscript.echo "In RunTlist(), Call to DriveObject.Freespace skipped!"
|
|
Wscript.echo "In RunTlist(), Err number after calling objFileSystem.GetDrive: " & err.number & " Err Description: " & err.description
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
End If
|
|
Else 'We are in hang mode but logging to a UNC path
|
|
|
|
|
|
Path = ShortHangDir
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "Path = " & Path
|
|
End If
|
|
NewPath = Right(Path, Len(Path) - 2)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "NewPath = " & NewPath
|
|
End If
|
|
PathArray = Split(NewPath, "\", -1)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "ServerName = " & PathArray(0)
|
|
End If
|
|
ServerName = PathArray(0)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "ShareName = " & PathArray(1)
|
|
End If
|
|
ShareName = PathArray(1)
|
|
NewPath = "\\" & ServerName & "\" & ShareName
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "NewPath = " & NewPath
|
|
End If
|
|
Set DriveObject = objFileSystem.GetDrive(NewPath)
|
|
|
|
If No_Free_Space_Checking = False Then
|
|
If DriveObject.FreeSpace < MinFreeSpace Then
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In RunEcmdm(), No_Free_Space_Checking = FALSE"
|
|
Wscript.echo "In RunTlist(), Err number after calling DriveObject.Freespace: " & err.number & " Err Description: " & err.description
|
|
Wscript.echo "In RunTlist(), Free space = " & DriveObject.FreeSpace
|
|
Wscript.echo "In RunTlist(), MinFreeSpace = " & MinFreeSpace
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
If QuietMode = False Then
|
|
objShell.popup "AutodumpPlus has detected that there is not enough free space on the following network share " & HangDir & ". AutodumpPlus requires at least 10Mb of free space. Please free up some space on that drive and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "AutodumpPlus has detected that there is not enough free space on the following network share " & HangDir & ". AutodumpPlus requires at least 10Mb of free space. Please free up some space on that drive and try running AutodumpPlus again."
|
|
wscript.echo "AutodumpPlus has detected that there is not enough free space on the following network share " & HangDir & ". AutodumpPlus requires at least 10Mb of free space. Please free up some space on that drive and try running AutodumpPlus again."
|
|
End If
|
|
DeleteDirectory(ShortHangDir)
|
|
wscript.quit 1
|
|
End If
|
|
Else
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In RunTlist(), No_Free_Space_Checking = TRUE"
|
|
Wscript.echo "In RunTlist(), Call to DriveObject.Freespace skipped!"
|
|
Wscript.echo "In RunTlist(), Err number after calling objFileSystem.GetDrive: " & err.number & " Err Description: " & err.description
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
End If
|
|
|
|
|
|
End If
|
|
|
|
|
|
End If
|
|
|
|
If CrashMode = true Then
|
|
strShell = "cmd /c " & chr(34) & InstallDir & "\tlist.exe" & Chr(34) & " -k >" & ShortCrashDir & "\Process_List.txt"
|
|
'Un-comment the line below in order to simulate the effects of a missing Process_List.txt file
|
|
'strShell = "cmd /c " & chr(34) & InstallDir & "\tlist.exe -k"
|
|
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In RunTlist(), about to run tlist.exe, the strShell (emcmd command string) is: " & StrShell
|
|
Wscript.Echo ""
|
|
wscript.echo "-----------------------"
|
|
End If
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,TRUE
|
|
Else
|
|
strShell = "cmd /c " & chr(34) & InstallDir & "\tlist.exe" & Chr(34) & " -k >" & ShortHangDir & "\Process_List.txt"
|
|
'Un-comment the line below in order to simulate the effects of a missing Process_List.txt file
|
|
'strShell = "cmd /c " & chr(34) & InstallDir & "\tlist.exe -k"
|
|
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In RunTlist(), about to run tlist.exe, the strShell (emcmd command string) is: " & StrShell
|
|
Wscript.Echo ""
|
|
wscript.echo "-----------------------"
|
|
End If
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,TRUE
|
|
End If
|
|
|
|
End Sub
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: CreateCDBScript
|
|
' This function is used to create the CDB scripts used by the debugger.
|
|
' If you wish to change the debug output for hangs, crashes, or quick mode, you can
|
|
' add the necessary debugger commands so that they are placed in the CDB scripts the
|
|
' next time AutodumpPlus is run.
|
|
'---------------------------------------------------------------------------------------------
|
|
Function CreateCDBScript(pid, packagename)
|
|
On Error Resume Next
|
|
|
|
Dim objFileSystem
|
|
Dim objTextFile
|
|
Dim strFile
|
|
Dim arResults
|
|
Dim objShell
|
|
Dim strShell
|
|
Dim versionFile
|
|
|
|
If CrashMode = True Then
|
|
strFile = CrashDir & "\CDBScripts"
|
|
CreateDirectory(strFile)
|
|
strFile = CrashDir & "\CDBScripts\" & "PID-" & pid & "__" & packagename & ".cfg"
|
|
Else
|
|
strFile = HangDir & "\CDBScripts"
|
|
CreateDirectory(strFile)
|
|
strFile = HangDir & "\CDBScripts\" & "PID-" & pid & "__" & packagename & ".cfg"
|
|
End If
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "---------------------------------------"
|
|
Wscript.echo "In the CreateCDBScript() function . . ."
|
|
Wscript.echo "In CreateCDBScript(), pid = " & pid
|
|
Wscript.echo "In CreateCDBScript(), packagename = " & packagename
|
|
Wscript.echo "In CreateCDBScript(), strFile (the name of the CDB script to create) = " & strFile
|
|
Wscript.echo ""
|
|
Wscript.echo "----------------------------------------"
|
|
End If
|
|
|
|
|
|
Set objFileSystem = CreateObject("Scripting.FileSystemObject")
|
|
Set objShell = CreateObject("Wscript.Shell")
|
|
Set objTextFile = objFileSystem.CreateTextFile(strFile,True)
|
|
If CrashMode = True Then
|
|
If No_CrashMode_Log = FALSE Then
|
|
objTextFile.Writeline ".logopen " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & ".log"
|
|
Else
|
|
End If
|
|
objTextFile.Writeline ".echotimestamps"
|
|
objTextFile.Writeline ".sympath"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* --------- AutodumpPlus " & VERSION & " was started at: -----------"
|
|
objTextFile.Writeline ".time"
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* --------- AutodumpPlus " & VERSION & " was run on server: --------"
|
|
objTextFile.Writeline "* Server name: " & ComputerName
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* ------ OS Version Information displayed below. -------"
|
|
objTextFile.Writeline "!version"
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
|
|
'Setup the debug break exception handler
|
|
If PageHeapMode = False Then
|
|
If Full_Dump_on_CONTRL_C = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- Listing all thread stacks: ---;~*kb250;.echo;.echo --- Listing loaded modules: ---;lmv;.echo;.echo --- Modules with matching symbols:;lml;.echo;.echo --- Listing all locks: ---;!locks;.echo;.echo ----------------------------------------------------------------------;.echo CTRL-C was pressed to stop debugging this process!;.echo ----------------------------------------------------------------------;.echo Exiting the debugger at:;.time;.echo;.dump /mfh /c CTRL-C_was_pressed_to_stop_the_debugger_while_running_in_crash_mode.__Full_memory_dump_from_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__CTRL-C__full.dmp;!elog_str AutodumpPlus detected that CTRL-C was pressed to stop debugging " & packagename & " and has created a full memory dump of the process in the " & CrashDir & " directory;q" & Chr(34) & " bpe"
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- Listing all thread stacks: ---;~*kb250;.echo;.echo --- Listing loaded modules: ---;lmv;.echo;.echo --- Modules with matching symbols:;lml;.echo;.echo --- Listing all locks: ---;!locks;.echo;.echo ----------------------------------------------------------------------;.echo CTRL-C was pressed to stop debugging this process!;.echo ----------------------------------------------------------------------;.echo Exiting the debugger at:;.time;.echo;.dump -u /m /c CTRL-C_was_pressed_to_stop_the_debugger_while_running_in_crash_mode.__Mini_memory_dump_from_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__CTRL-C__mini.dmp;!elog_str AutodumpPlus detected that CTRL-C was pressed to stop debugging " & packagename & " and has created a mini-memory dump of the process in the " & CrashDir & " directory;q" & Chr(34) & " bpe"
|
|
End If
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- Debug Break exception - Faulting stack below! ---;~#;kvn250;.echo -----------------------------------;.dump /mfh /c Debug_break_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__Debug_break_exception__full.dmp;!elog_str AutodumpPlus generated a Debug Break Exception dump while running in pageheap mode;.echo;.echo;.echo --- A debug break exception was encountered ---;.echo - AutodumpPlus will now detach the debugger;.echo - and end the debugging session.;.echo -----------------------------------" & Chr(34) & " bpe"
|
|
End If
|
|
|
|
|
|
|
|
'Setup the invalid handle exception handler
|
|
If No_Dump_on_1st_Chance_Exception = True Then 'The user does not want a memory dump produced for a 1st chance exception.
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Invalid Handle exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Invalid Handle exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_invalid_handle_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_invalid_handle__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Invalid Handle exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " ch"
|
|
Else 'The user does want a memory dump produced for a 1st chance exception, now figure out which kind of memory dump (full or mini).
|
|
If Create_Full_Dump_on_1st_Chance_Exception = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Invalid Handle exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 1st_chance_invalid_handle_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__1st_chance_Invalid_Handle__full.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Invalid Handle exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_invalid_handle_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_invalid_handle__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Invalid Handle exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " ch"
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Invalid Handle exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump -u /m /c 1st_chance_invalid_handle_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__1st_chance_Invalid_Handle__mini.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Invalid Handle exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_invalid_handle_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_invalid_handle__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Invalid Handle exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " ch"
|
|
End If
|
|
End If
|
|
|
|
|
|
|
|
|
|
'Setup the illegal instruction exception handler
|
|
If No_Dump_on_1st_Chance_Exception = True Then 'The user does not want a memory dump produced for a 1st chance exception.
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Illegal Instruction exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Illegal Instruction exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Illegal_Instruction_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Illegal_Instruction__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Illegal Instruction exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " ii"
|
|
Else 'The user does want a memory dump produced for a 1st chance exception, now figure out which kind of memory dump (full or mini).
|
|
If Create_Full_Dump_on_1st_Chance_Exception = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Illegal Instruction exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 1st_chance_Illegal_Instruction_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__1st_chance_Illegal_Instruction__full.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Illegal Instruction exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Illegal_Instruction_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Illegal_Instruction__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Illegal Instruction exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " ii"
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Illegal Instruction exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump -u /m /c 1st_chance_Illegal_Instruction_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__1st_chance_Illegal_Instruction__mini.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Illegal Instruction exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Illegal_Instruction_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Illegal_Instruction__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Illegal Instruction exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " ii"
|
|
End If
|
|
End If
|
|
|
|
|
|
|
|
'Setup the Integer Divide by Zero exception handler
|
|
If No_Dump_on_1st_Chance_Exception = True Then 'The user does not want a memory dump produced for a 1st chance exception.
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Integer Divide by Zero exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Integer Divide by Zero exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Integer_Divide_by_Zero_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Integer_Divide_by_Zero__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Integer Divide by Zero exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " dz"
|
|
Else 'The user does want a memory dump produced for a 1st chance exception, now figure out which kind of memory dump (full or mini).
|
|
If Create_Full_Dump_on_1st_Chance_Exception = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Integer Divide by Zero exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 1st_chance_Integer_Divide_by_Zero_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__1st_chance_Integer_Divide_by_Zero__full.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Integer Divide by Zero exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Integer_Divide_by_Zero_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Integer_Divide_by_Zero__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Integer Divide by Zero exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " dz"
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Integer Divide by Zero exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump -u /m /c 1st_chance_Integer_Divide_by_Zero_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__1st_chance_Integer_Divide_by_Zero__mini.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Integer Divide by Zero exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Integer_Divide_by_Zero_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Integer_Divide_by_Zero__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Integer Divide by Zero exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " dz"
|
|
End If
|
|
End If
|
|
|
|
|
|
|
|
'Setup the Floating Point Divide by Zero exception handler
|
|
If No_Dump_on_1st_Chance_Exception = True Then 'The user does not want a memory dump produced for a 1st chance exception.
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Floating Point Divide by Zero exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Floating Point Divide by Zero exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Floating_Point_Divide_by_Zero_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Floating_Point_Divide_by_Zero__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Floating Point Divide by Zero exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " c000008e"
|
|
Else 'The user does want a memory dump produced for a 1st chance exception, now figure out which kind of memory dump (full or mini).
|
|
If Create_Full_Dump_on_1st_Chance_Exception = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Floating Point Divide by Zero exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 1st_chance_Floating_Point_Divide_by_Zero_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__1st_chance_Floating_Point_Divide_by_Zero__full.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Floating Point Divide by Zero exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Floating_Point_Divide_by_Zero_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Floating_Point_Divide_by_Zero__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Floating Point Divide by Zero exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " c000008e"
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Floating Point Divide by Zero exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump -u /m /c 1st_chance_Floating_Point_Divide_by_Zero_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__1st_chance_Floating_Point_Divide_by_Zero__mini.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Floating Point Divide by Zero exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Floating_Point_Divide_by_Zero_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Floating_Point_Divide_by_Zero__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Floating Point Divide by Zero exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " c000008e"
|
|
End If
|
|
End If
|
|
|
|
|
|
|
|
'Setup the Integer Overflow exception handler
|
|
If No_Dump_on_1st_Chance_Exception = True Then 'The user does not want a memory dump produced for a 1st chance exception.
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Integer Overflow exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Integer Overflow exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Integer_Overflow_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Integer_Overflow__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Integer Overflow exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " dz"
|
|
Else 'The user does want a memory dump produced for a 1st chance exception, now figure out which kind of memory dump (full or mini).
|
|
If Create_Full_Dump_on_1st_Chance_Exception = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Integer Overflow exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 1st_chance_Integer_Overflow_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__1st_chance_Integer_Overflow__full.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Integer Overflow exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Integer_Overflow_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Integer_Overflow__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Integer Overflow exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " dz"
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Integer Overflow exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump -u /m /c 1st_chance_Integer_Overflow_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__1st_chance_Integer_Overflow__mini.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Integer Overflow exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Integer_Overflow_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Integer_Overflow__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Integer Overflow exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " dz"
|
|
End If
|
|
End If
|
|
|
|
|
|
|
|
|
|
'Setup the Invalid Lock Sequence exception handler
|
|
If No_Dump_on_1st_Chance_Exception = True Then 'The user does not want a memory dump produced for a 1st chance exception.
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Invalid Lock Sequence exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Invalid Lock Sequence exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Invalid_Lock_Sequence_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Invalid_Lock_Sequence__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Invalid Lock Sequence exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " lsq"
|
|
Else 'The user does want a memory dump produced for a 1st chance exception, now figure out which kind of memory dump (full or mini).
|
|
If Create_Full_Dump_on_1st_Chance_Exception = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Invalid Lock Sequence exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 1st_chance_Invalid_Lock_Sequence_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__1st_chance_Invalid_Lock_Sequence__full.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Invalid Lock Sequence exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Invalid_Lock_Sequence_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Invalid_Lock_Sequence__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Invalid Lock Sequence exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " lsq"
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Invalid Lock Sequence exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump -u /m /c 1st_chance_Invalid_Lock_Sequence_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__1st_chance_Invalid_Lock_Sequence__mini.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Invalid Lock Sequence exception - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_Invalid_Lock_Sequence_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_Invalid_Lock_Sequence__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Invalid Lock Sequence exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " lsq"
|
|
End If
|
|
End If
|
|
|
|
|
|
|
|
|
|
'Setup the Acces Violation exception handler
|
|
If No_Dump_on_1st_Chance_Exception = True Then 'The user does not want a memory dump produced for a 1st chance exception.
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Access Violation - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Acess Violation - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_access_violation_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_access_violation__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Access Violation exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " av"
|
|
Else 'The user does want a memory dump produced for a 1st chance exception, now figure out which kind of memory dump (full or mini).
|
|
If Create_Full_Dump_on_1st_Chance_Exception = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Access Violation - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 1st_chance_access_violation_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__1st_chance_access_violation__full.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Acess Violation - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_access_violation_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_access_violation__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Access Violation exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " av"
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Access Violation - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump -u /m /c 1st_chance_access_violation_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__1st_chance_access_violation__mini.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance Acess Violation - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_access_violation_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_access_violation__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Access Violation exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " av"
|
|
End If
|
|
End If
|
|
|
|
|
|
|
|
'Setup the Stack Overflow exception handler
|
|
If No_Dump_on_1st_Chance_Exception = True Then 'The user does not want a memory dump produced for a 1st chance exception.
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Stack Overflow - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance stack overflow - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_stack_overflow_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance__stack_overflow__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Stack Overflow exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " sov"
|
|
Else 'The user does want a memory dump produced for a 1st chance exception, now figure out which kind of memory dump (full or mini).
|
|
If Create_Full_Dump_on_1st_Chance_Exception = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Stack Overflow - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 1st_chance_stack_overflow_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__1st_chance_stack_overflow__full.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance stack overflow - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_stack_overflow_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance__stack_overflow__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Stack Overflow exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " sov"
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Stack Overflow - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump -u /m /c 1st_chance_stack_overflow_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__1st_chance_stack_overflow__mini.dmp;.echo;.echo;gn" & Chr(34) & " -c2 " & Chr(34) & ".echo --- 2nd chance stack overflow - Faulting stack below ---;~#;kvn250;.dump /mfh /c 2nd_chance_stack_overflow_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance__stack_overflow__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Stack Overflow exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " sov"
|
|
End If
|
|
End If
|
|
|
|
|
|
|
|
'Setup the C++ EH exception handler
|
|
'By default C++ EH exceptions are only logged to the log file (if logging is enabled) and there is no memory dump produced to minimize the impact on performance.
|
|
If Dump_on_EH_Exceptions = TRUE AND No_Dump_on_1st_Chance_Exception = FALSE Then 'Check to see whether we should produce a mini dump or a full memory dump
|
|
If Create_Full_Dump_on_1st_Chance_Exception = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance C++ EH exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 1st_chance_C++_EH_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__1st_chance_C++_EH_exception__full.dmp;.echo;.echo;gn" & Chr(34) & "-c2 " & Chr(34) & ".echo --- 2nd chance C++ EH exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 2nd_chance_C++_EH_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_C++_EH__full.dmp;!elog_str AutodumpPlus detected a 2nd chance EH exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " eh"
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance C++ EH exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump -u /m /c 1st_chance_C++_EH_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__1st_chance_C++_EH_exception__mini.dmp;.echo;.echo;gn" & Chr(34) & "-c2 " & Chr(34) & ".echo --- 2nd chance C++ EH exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 2nd_chance_C++_EH_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_C++_EH__full.dmp;!elog_str AutodumpPlus detected a 2nd chance EH exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " eh"
|
|
End If
|
|
Else 'By default, ADPlus does not produce a memory dump on 1st chance EH exceptions, it just logs the stack and continues without handling the exception (gn).
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance C++ EH exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.echo;.echo;gn" & Chr(34) & "-c2 " & Chr(34) & ".echo --- 2nd chance C++ EH exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 2nd_chance_C++_EH_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_C++_EH__full.dmp;q" & Chr(34) & " eh"
|
|
End If
|
|
|
|
|
|
|
|
'Setup the unknown exception handler
|
|
'By default unknown exceptions are only logged to the log file (if logging is enabled) and there is no memory dump produced to minimize the impact on performance.
|
|
If Dump_on_Unknown_Exceptions = TRUE AND No_Dump_on_1st_Chance_Exception = FALSE Then 'Check to see whether we should produce a mini dump or a full memory dump
|
|
If Create_Full_Dump_on_1st_Chance_Exception = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Unknown exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 1st_chance_unknown_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__1st_chance_unknown_exception__full.dmp;.echo;.echo;gn" & Chr(34) & "-c2 " & Chr(34) & ".echo --- 2nd chance unknown exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 2nd_chance_Unknown_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_unknown_exception__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Unknown exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " *"
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Unknown exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump -u /m /c 1st_chance_unknown_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__1st_chance_unknown_exception__mini.dmp;.echo;.echo;gn" & Chr(34) & "-c2 " & Chr(34) & ".echo --- 2nd chance unknown exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 2nd_chance_Unknown_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_unknown_exception__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Unknown exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " *"
|
|
End If
|
|
Else 'By default, ADPlus does not produce a memory dump on 1st chance unknown exceptions, it just logs the stack and continues without handling the exception (gn).
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- 1st chance Unknown exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.echo;.echo;gn" & Chr(34) & "-c2 " & Chr(34) & ".echo --- 2nd chance unknown exception - Faulting stack below ----;~#;kvn250;.echo -----------------------------------;.dump /mfh /c 2nd_chance_Unknown_exception_in_" & packagename & "_running_on_" & ComputerName & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__2nd_chance_unknown_exception__full.dmp;!elog_str AutodumpPlus detected a 2nd chance Unknown exception in process " & packagename & " and has created a full memory dump of the process at the time of the crash in the " & CrashDir & " directory;q" & Chr(34) & " *"
|
|
End If
|
|
|
|
|
|
|
|
'Setup the DLL Load exception handler
|
|
If Dump_Stack_on_DLL_Load = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- A DLL was loaded - Stack back trace below ----;~#;kvn250;.echo -----------------------------------;.echo;gn" & Chr(34) & " ld"
|
|
End If
|
|
|
|
|
|
|
|
'Setup the DLL UnLoad exception handler
|
|
If Dump_Stack_on_DLL_UnLoad = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo --- A DLL was un-loaded - Stack back trace below ----;~#;kvn250;.echo -----------------------------------;.echo;gn" & Chr(34) & " ud"
|
|
End If
|
|
|
|
|
|
|
|
'Setup the end process exception handler
|
|
If Create_Full_Dump_on_1st_Chance_Exception = TRUE Then
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo;.echo ----------------------------------------------------------------------;.echo This process is shutting down!;.echo;.echo This can happen for the following reasons:;.echo 1.) Someone killed the process with Task Manager or the kill command.;.echo;.echo 2.) If this process is an MTS or COM+ server package, it could be;.echo* exiting because an MTS/COM+ server package idle limit was reached.;.echo;.echo 3.) If this process is an MTS or COM+ server package,;.echo* someone may have shutdown the package via the MTS Explorer or;.echo* Component Services MMC snap-in.;.echo;.echo 4.) If this process is an MTS or COM+ server package,;.echo* MTS or COM+ could be shutting down the process because an internal;.echo* error was detected in the process (MTS/COM+ fail fast condition).;.echo ----------------------------------------------------------------------;.echo;.echo --- Listing all remaining threads at time of shutdown ----;~*kv250;.echo ----------------------------------------------------------------------;.echo;.echo The process was shut down at:;.time;.echo;.echo;.dump /mfh /c The_following_process_" & packagename & "_running_on_" & ComputerName & "_was_shutdown_or_killed" & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__Process_was_shutdown__full.dmp;!elog_str AutodumpPlus detected that the following process " & packagename & " is shutting down or was killed and has created a full memory dump of the process at the time of the shutdown in the " & CrashDir & " directory;" & Chr(34) & " epr"
|
|
Else
|
|
objTextFile.Writeline "sxe -c " & Chr(34) & ".echo;.echo ----------------------------------------------------------------------;.echo This process is shutting down!;.echo;.echo This can happen for the following reasons:;.echo 1.) Someone killed the process with Task Manager or the kill command.;.echo;.echo 2.) If this process is an MTS or COM+ server package, it could be;.echo* exiting because an MTS/COM+ server package idle limit was reached.;.echo;.echo 3.) If this process is an MTS or COM+ server package,;.echo* someone may have shutdown the package via the MTS Explorer or;.echo* Component Services MMC snap-in.;.echo;.echo 4.) If this process is an MTS or COM+ server package,;.echo* MTS or COM+ could be shutting down the process because an internal;.echo* error was detected in the process (MTS/COM+ fail fast condition).;.echo ----------------------------------------------------------------------;.echo;.echo --- Listing all remaining threads at time of shutdown ----;~*kv250;.echo ----------------------------------------------------------------------;.echo;.echo The process was shut down at:;.time;.echo;.echo;.dump -u /m /c The_following_process_" & packagename & "_running_on_" & ComputerName & "_was_shutdown_or_killed" & " " & ShortCrashDir & "\" & "PID-" & pid & "__" & packagename & "__Process_was_shutdown__mini.dmp;!elog_str AutodumpPlus detected that the following process " & packagename & " is shutting down or was killed and has created a mini-memory dump of the process at the time of the shutdown in the " & CrashDir & " directory;" & Chr(34) & " epr"
|
|
End If
|
|
|
|
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* AutodumpPlus is monitoring: " & packagename
|
|
objTextFile.Writeline "* for most types of 1st chance and 2nd chance exceptions."
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* When a first chance exception is encountered, the process is paused"
|
|
objTextFile.Writeline "* while the faulting thread's stack is logged to a .log file and a"
|
|
objTextFile.Writeline "* mini-memory dump is created. The process will then resume."
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* If a second chance exception is encountered, the process is paused"
|
|
objTextFile.Writeline "* while the faulting thread's stack is logged to a .log file and a"
|
|
objTextFile.Writeline "* full memory dump is created. The debugger then quits and the process"
|
|
objTextFile.Writeline "* may need to be re-started."
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* C++ EH and Unknown exceptions, by deafult, will not produce memory"
|
|
objTextFile.Writeline "* dumps on 1st chance exceptions (see Q286350 for more info)."
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* If this process hangs, or to stop debugging this process please press"
|
|
objTextFile.Writeline "* CTRL-C in this window to produce a memory dump and to stop debugging."
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* NOTE: To stop debugging this process, do NOT close this window by"
|
|
objTextFile.Writeline "* pressing the X button at the top-right corner, please press CTRL-C to"
|
|
objTextFile.Writeline "* stop debugging. After pressing CTRL-C in this window, you will need to"
|
|
objTextFile.Writeline "* re-start this process. If you are monitoring IIS 5.0, IIS 5.0 will be"
|
|
objTextFile.Writeline "* re-started automatically by the Windows 2000 Service Control Manager."
|
|
'Setup the DLL Load / Unload information
|
|
If (Dump_Stack_on_DLL_Load = TRUE or Dump_Stack_on_DLL_UnLoad) Then
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* -------------------- Listing loaded modules -------------------------"
|
|
objTextFile.Writeline "lmv"
|
|
objTextFile.Writeline "* ---------------------------------------------------------------------"
|
|
End If
|
|
objTextFile.Writeline "g"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* -------- AutodumpPlus " & VERSION & " finished running at: --------"
|
|
objTextFile.Writeline ".time"
|
|
objTextFile.Writeline "* -------------------------------------------------------"
|
|
|
|
'If the -notify switch was used then send a message to the computer or user specified on the command line
|
|
'Note on NT 4.0 LocalUserName will be blank because the Volatile Environment variable can only be quired on Windows 2000 to get the
|
|
'local username. So we must send the message from the NotifyTarget on NT 4.0, instead of the locally logged on user.
|
|
If NotifyAdmin = True Then
|
|
If OSVer = "4.0" Then
|
|
objTextFile.Writeline "!net_send " & ComputerName & " " & NotifyTarget & " " & NotifyTarget & " AutodumpPlus has finished running in crash mode on " & ComputerName & " for the following process: " & packagename & ". This could indicate that a crash has occurred, or that the debugging session was ended manually (CTRL-C was pressed to stop debugging). Please check the application event log on " & ComputerName & " for more information."
|
|
Else
|
|
objTextFile.Writeline "!net_send " & ComputerName & " " & NotifyTarget & " " & LocalUsername & " AutodumpPlus has finished running in crash mode on " & ComputerName & " for the following process: " & packagename & ". This could indicate that a crash has occurred, or that the debugging session was ended manually (CTRL-C was pressed to stop debugging). Please check the application event log on " & ComputerName & " for more information."
|
|
End If
|
|
End If
|
|
objTextFile.Writeline "q"
|
|
|
|
ElseIf QuickMode = True Then
|
|
objTextFile.Writeline ".logopen " & ShortHangDir & "\" & "PID-" & pid & "__" & packagename & "__" & DateTimeStamp & ".log"
|
|
objTextFile.Writeline "*.reload /s"
|
|
objTextFile.Writeline ".sympath"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* --------- AutodumpPlus " & VERSION & " was started at: -----------"
|
|
objTextFile.Writeline ".time"
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* --------- OS Version Information: ---------------------"
|
|
objTextFile.Writeline "!version"
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* --------- AutodumpPlus " & VERSION & " was run on server: --------"
|
|
objTextFile.Writeline "* Server name: " & ComputerName
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* --------- Heap information: --------------------------"
|
|
objTextFile.Writeline "!heap 0 -k"
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* --------- Handle information: ------------------------"
|
|
objTextFile.Writeline "!handle 0 0"
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* -------- Thread stack backtrace information: ---------"
|
|
objTextFile.Writeline "~*kb250"
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* -------- Loaded modules: -----------------------------"
|
|
objTextFile.Writeline "lmv"
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* -------- Loaded modules with matching symbols: -------"
|
|
objTextFile.Writeline "lml"
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* -------- DLL Information: ----------------------------"
|
|
objTextFile.Writeline "!dlls"
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* -------- Critical section information: ---------------"
|
|
objTextFile.Writeline "!locks"
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "* -------- Time & Uptime Statistics: -------------------"
|
|
objTextFile.Writeline "* Time & Uptime Statistics:"
|
|
objTextFile.Writeline ".time"
|
|
objTextFile.Writeline "* ------------------------------------------------------"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline "*"
|
|
objTextFile.Writeline ".dump -u /m /c " & Chr(34) & "Mini memory dump for " & packagename & " created by AutodumpPlus Version " & VERSION & " running on " & ComputerName & " in quick/hang mode!" & Chr(34) & " " & ShortHangDir & "\PID-" & pid & "__" & packagename & "__mini.dmp"
|
|
objTextFile.Writeline ".logclose"
|
|
objTextFile.Writeline "q"
|
|
Else
|
|
objTextFile.Writeline ".dump /mfh /c " & Chr(34) & "Full memory dump for " & packagename & " created by AutodumpPlus Version " & VERSION & " running on " & ComputerName & " in normal/hang mode!" & Chr(34) & " " & ShortHangDir & "\PID-" & pid & "__" & packagename & "__" & DateTimeStamp & "__full.dmp"
|
|
objTextFile.Writeline "q"
|
|
End If
|
|
|
|
|
|
objTextFile.Close
|
|
Set objFileSystem = nothing
|
|
Set objTextFile = nothing
|
|
Set objShell = nothing
|
|
CreateCDBScript = strFile
|
|
|
|
End Function
|
|
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: DumpIIS
|
|
' This is a rather large function and it is the main function used to dump
|
|
' all of the MTS / COM+ processes when running in either quick or normal mode.
|
|
' Generic processes (those specified by the -p or -pn switch) are dumped using the
|
|
' DumpAnyProc() function.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub DumpIIS(strFile,OSVersion)
|
|
On Error Resume Next
|
|
|
|
Dim objFileSystem
|
|
Dim oFS2
|
|
Dim objTextFile
|
|
Dim str
|
|
Dim arResults
|
|
Dim objShell
|
|
Dim strShell
|
|
Dim versionFile
|
|
Dim TempCounter
|
|
Dim i
|
|
Dim TotalPackageCount
|
|
Dim WheresTheSpace
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the DumpIIS() function . . ."
|
|
Wscript.echo "In DumpIIS(), strFile = " & strFile
|
|
Wscript.echo "In DumpIIS(), OSVersion = " & OSVersion
|
|
Wscript.echo ""
|
|
End If
|
|
i = 0
|
|
Set objFileSystem = CreateObject("Scripting.FileSystemObject")
|
|
Set oFS2 = CreateObject("Scripting.FileSystemObject")
|
|
Set objShell = CreateObject("Wscript.Shell")
|
|
|
|
'Per the scripting team's advice, sleep for .5 second prior to calling this function.
|
|
Wscript.sleep 500
|
|
If CrashMode = true Then
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), The Process_List.txt file should be located here: " & CrashDir & "\Process_List.txt"
|
|
Wscript.echo ""
|
|
End If
|
|
While not objFileSystem.FileExists(CrashDir & "\Process_List.txt")
|
|
Wscript.sleep 1000
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpIIS(), The Process_List.txt file has not been created yet, sleeping for 1 second and trying again."
|
|
wscript.echo ""
|
|
End If
|
|
i = i +1
|
|
If i = 10 Then
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpIIS(), Could not find the Process_List.txt file in the folder: " & CrashDir
|
|
wscript.echo "In DumpIIS(), Exiting AutodumpPlus now."
|
|
wscript.echo ""
|
|
End If
|
|
If QuietMode = False Then
|
|
objShell.PopUp "The file Process_List.txt could not be found in the " & CrashDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "The file Process_List.txt could not be found in the " & CrashDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
objShell.LogEvent 1, "The file Process_List.txt could not be found in the " & CrashDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
If HangMode = True Then
|
|
DeleteDirectory(HangDir)
|
|
Else
|
|
DeleteDirectory(CrashDir)
|
|
End If
|
|
|
|
wscript.quit 1
|
|
End If
|
|
|
|
Wend
|
|
Else 'Running in Hang or Quick modes . . .
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), The Process_List.txt file should be located here: " & HangDir & "\Process_List.txt"
|
|
End If
|
|
While not objFileSystem.FileExists(HangDir & "\Process_List.txt")
|
|
Wscript.sleep 1000
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpIIS(), The Process_List.txt file has not been created yet, sleeping for 1 second and trying again."
|
|
wscript.echo ""
|
|
End If
|
|
i = i +1
|
|
If i = 10 Then
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpIIS(), Could not find the Process_List.txt file in the folder: " & HangDir
|
|
wscript.echo "In DumpIIS(), Exiting AutodumpPlus now."
|
|
wscript.echo ""
|
|
End If
|
|
If QuietMode = False Then
|
|
objShell.PopUp "The file Process_List.txt could not be found in the " & HangDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "The file Process_List.txt could not be found in the " & HangDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
objShell.LogEvent 1, "The file Process_List.txt could not be found in the " & HangDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
If HangMode = True Then
|
|
DeleteDirectory(HangDir)
|
|
Else
|
|
DeleteDirectory(CrashDir)
|
|
End If
|
|
|
|
wscript.quit 1
|
|
End If
|
|
|
|
Wend
|
|
End If
|
|
|
|
If HangMode = True Then
|
|
Set objTextFile = objFileSystem.OpenTextFile(HangDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
Else
|
|
Set objTextFile = objFileSystem.OpenTextFile(CrashDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
End If
|
|
i = 0
|
|
While objTextFile.AtEndOfStream
|
|
'Close the text file to let it finish writing and to get a new copy . . .
|
|
objTextFile.Close
|
|
wscript.sleep 1000
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpIIS(), Waiting for Process_List.txt to finish writing (sleeping 1 second). . . "
|
|
wscript.echo ""
|
|
End If
|
|
i = i +1
|
|
If i = 10 Then
|
|
If HangMode = True Then
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpIIS(), Process_List.txt was never closed (finished writing) in the folder: " & HangDir
|
|
wscript.echo "In DumpIIS(), Exiting AutodumpPlus now."
|
|
wscript.echo ""
|
|
End If
|
|
If QuietMode = False Then
|
|
objShell.PopUp "The file Process_List.txt was never closed (finished writing) by tlist.exe in the " & HangDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "The file Process_List.txt was never closed (finished writing) by tlist.exe in the " & HangDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
objShell.LogEvent 1, "The file Process_List.txt was never closed (finished writing) by tlist.exe in the " & HangDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
DeleteDirectory(HangDir)
|
|
wscript.quit 1
|
|
Else
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpIIS(), Process_List.txt was never closed (finished writing) in the folder: " & CrashDir
|
|
wscript.echo "In DumpIIS(), Exiting AutodumpPlus now."
|
|
wscript.echo ""
|
|
End If
|
|
If QuietMode = False Then
|
|
objShell.PopUp "The file Process_List.txt was never closed (finished writing) by tlist.exe in the " & CrashDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "The file Process_List.txt was never closed (finished writing) by tlist.exe in the " & CrashDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
objShell.LogEvent 1, "The file Process_List.txt was never closed (finished writing) by tlist.exe in the " & CrashDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
DeleteDirectory(CrashDir)
|
|
wscript.quit 1
|
|
End If
|
|
End If
|
|
'Open the text file again before looping . . .
|
|
If HangMode = True Then
|
|
Set objTextFile = objFileSystem.OpenTextFile(HangDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
Else
|
|
Set objTextFile = objFileSystem.OpenTextFile(CrashDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
End If
|
|
|
|
Wend
|
|
|
|
While not objTextFile.AtEndofStream
|
|
str = objTextFile.ReadLine
|
|
Str = LTrim(Str)
|
|
arResults= split(Str," ",-1,1)
|
|
arResults(1)=trim(arResults(1))
|
|
arResults(1)=Replace(arResults(1),"/",",")
|
|
arResults(1)=Replace(arResults(1),"\",",")
|
|
arResults(1)=Replace(arResults(1),"<","(")
|
|
arResults(1)=Replace(arResults(1),">",")")
|
|
arResults(1)=Replace(arResults(1),":","")
|
|
arResults(1)=Replace(arResults(1),"*","")
|
|
arResults(1)=Replace(arResults(1),"?","")
|
|
arResults(1)=Replace(arResults(1),"|","")
|
|
If UCase(arResults(1)) = "INETINFO.EXE" Then
|
|
IISPid = Trim(arResults(0))
|
|
End If
|
|
Wend
|
|
|
|
objTextFile.Close
|
|
|
|
|
|
If DEBUGGING = True Then
|
|
wscript.echo ""
|
|
wscript.echo "In DumpIIS(), strFile = " & strFile
|
|
wscript.echo "In DumpIIS(), about to open strFile for reading . . ."
|
|
End If
|
|
|
|
'Open the Process_List.txt and count how many packages / applications are running.
|
|
'This code was updated to limit ADPlus to only attaching to up to MAX_APPLICATIONS_TO_DEBUG
|
|
'NOTE: If there are more than MAX_APPLICATIONS_TO_DEBUG applications running ADPlus will
|
|
'display an error and quit.
|
|
|
|
Set objTextFile = objFileSystem.OpenTextFile(strFile,ForReading,TristateUseDefault)
|
|
While not objTextFile.AtEndofStream
|
|
str = objTextFile.ReadLine
|
|
Str = LTrim(Str)
|
|
If InStr(Str, "Mts:") Then
|
|
arResults= split(Str,":",-1,1)
|
|
arResults(1)=trim(arResults(1))
|
|
arResults(1)=Replace(arResults(1),"/",",")
|
|
arResults(1)=Replace(arResults(1),"\",",")
|
|
arResults(1)=Replace(arResults(1),"<","(")
|
|
arResults(1)=Replace(arResults(1),">",")")
|
|
arResults(1)=Replace(arResults(1),":","")
|
|
arResults(1)=Replace(arResults(1),"*","")
|
|
arResults(1)=Replace(arResults(1),"?","")
|
|
arResults(1)=Replace(arResults(1),"|","")
|
|
arResults(0)=LTrim(arResults(0))
|
|
WheresTheSpace = InStr(arResults(0)," ")
|
|
arResults(0)= Left(arResults(0),(WheresTheSpace-1))
|
|
TotalPackageCount = TotalPackageCount+1
|
|
End if
|
|
Wend
|
|
|
|
'Close the text file.
|
|
objTextFile.Close
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS() TotalPackageCount = " & TotalPackageCount
|
|
End If
|
|
|
|
'This is the logic to display the error message if too many packages / applications are running when
|
|
'used with the -IIS switch.
|
|
If TotalPackageCount > MAX_APPLICATIONS_TO_DEBUG Then
|
|
If OSVersion = "4.0" Then
|
|
If QuietMode = False Then
|
|
objShell.PopUp "AutodumpPlus has determined that there are currently " & TotalpackageCount & " MTS server packages running. AutodumpPlus when used with the '-IIS' switch, by default, will only monitor up to " & MAX_APPLICATIONS_TO_DEBUG & " MTS server packages because of the impact on system resources.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "AutodumpPlus has determined that there are currently " & TotalpackageCount & " MTS server packages running. AutodumpPlus when used with the '-IIS' switch, by default, will only monitor up to " & MAX_APPLICATIONS_TO_DEBUG & " MTS server packages because of the impact on system resources."
|
|
objShell.LogEvent 1, "AutodumpPlus has determined that there are currently " & TotalpackageCount & " MTS server packages running. AutodumpPlus when used with the '-IIS' switch, by default, will only monitor up to " & MAX_APPLICATIONS_TO_DEBUG & " MTS server packages because of the impact on system resources."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
'Delete the crash or hang mode directory since we are quitting.
|
|
If HangMode = True Then
|
|
Call DeleteDirectory(HangDir)
|
|
Else
|
|
Call DeleteDirectory(CrashDir)
|
|
End If
|
|
|
|
wscript.quit 1
|
|
Else
|
|
If QuietMode = False Then
|
|
objShell.PopUp "AutodumpPlus has determined that there are currently " & TotalpackageCount & " COM+ server applications running. AutodumpPlus when used with the '-IIS' switch, by default, will only monitor up to " & MAX_APPLICATIONS_TO_DEBUG & " COM+ server applications because of the impact on system resources.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "AutodumpPlus has determined that there are currently " & TotalpackageCount & " COM+ server applications running. AutodumpPlus when used with the '-IIS' switch, by default, will only monitor up to " & MAX_APPLICATIONS_TO_DEBUG & " COM+ server applications because of the impact on system resources."
|
|
objShell.LogEvent 1, "AutodumpPlus has determined that there are currently " & TotalpackageCount & " COM+ server applications running. AutodumpPlus when used with the '-IIS' switch, by default, will only monitor up to " & MAX_APPLICATIONS_TO_DEBUG & " COM+ server applications because of the impact on system resources."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
'Delete the crash or hang mode directory since we are quitting.
|
|
If HangMode = True Then
|
|
Call DeleteDirectory(HangDir)
|
|
Else
|
|
Call DeleteDirectory(CrashDir)
|
|
End If
|
|
wscript.quit 1
|
|
End If
|
|
End If
|
|
|
|
'Open the Process_List.txt
|
|
Set objTextFile = objFileSystem.OpenTextFile(strFile,ForReading,TristateUseDefault)
|
|
|
|
if not objTextFile.AtEndOfStream Then
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpIIS(), Succesffully opened the file " & strFile & ". tlist.exe -k appears to have run."
|
|
wscript.echo ""
|
|
End If
|
|
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpIIS(), The first line of " & strFile & " contains: " & Str
|
|
wscript.echo ""
|
|
End If
|
|
|
|
If HangMode = true and QuickMode = true Then
|
|
Wscript.Echo "The '-quick' switch was used, AutodumpPlus is running in 'quick hang' mode."
|
|
ElseIf HangMode = true Then
|
|
Wscript.echo "The '-hang' switch was used, Autdoump is running in 'hang' mode."
|
|
End If
|
|
|
|
If CrashMode = true Then
|
|
Wscript.Echo "The '-crash' switch was used, AutodumpPlus is running in 'crash' mode."
|
|
End If
|
|
|
|
If PageHeapMode = true Then
|
|
Wscript.Echo "The '-pageheap' switch was used, AutodumpPlus is running in 'pageheap' mode."
|
|
End If
|
|
|
|
If QuietMode = true Then
|
|
Wscript.Echo "The '-quiet' switch was used, AutodumpPlus will not display any"
|
|
Wscript.Echo "modal dialog boxes."
|
|
End If
|
|
|
|
If OSwitchUsed = true Then
|
|
Wscript.Echo "The '-o' switch was used. AutodumpPlus will place all files in"
|
|
Wscript.echo "the following directory: " & OutputDir
|
|
End If
|
|
|
|
If NotifyAdmin = true Then
|
|
Wscript.Echo "The '-notify' switch was used. AutodumpPlus will send notification to"
|
|
Wscript.echo "the following computer or user: " & NotifyTarget
|
|
End If
|
|
|
|
If CrashMode = True Then
|
|
If OSVersion = "4.0" Then
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Monitoring IIS and all MTS server packages for crashes."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
ElseIf CInt(OSBuildNumber) = 2195 Then
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Monitoring IIS and all COM+ server applications"
|
|
Wscript.Echo "except for the System application for crashes."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
ElseIf CInt(OSBuildNumber) > 2195 Then
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Monitoring IIS and all COM+ server applications for crashes."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
End If
|
|
ElseIf QuickMode = True Then
|
|
If OSVersion = "4.0" Then
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Logging debug info for IIS and all MTS server packages."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
ElseIf CInt(OSBuildNumber) = 2195 Then
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Logging debug info for IIS and all COM+ server applications"
|
|
Wscript.Echo "except for the System application."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
ElseIf CInt(OSBuildNumber) > 2195 Then
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Logging debug info for IIS and all COM+ server applications."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
End If
|
|
Else
|
|
If OSVersion = "4.0" Then
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Dumping process info for IIS and all MTS server packages."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
ElseIf CInt(OSBuildNumber) = 2195 Then
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Dumping process info for IIS and all COM+ server applications"
|
|
Wscript.Echo "except for the System application."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
ElseIf CInt(OSBuildNumber) > 2195 Then
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Dumping process info for IIS and all COM+ server applications."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
End If
|
|
End If
|
|
|
|
|
|
If CrashMode = true Then
|
|
If IISPid <> "" Then
|
|
PackageCount = PackageCount + 1
|
|
IISProcessCount = IISProcessCount + 1
|
|
Wscript.Echo "Attaching the CDB debugger to: IIS (inetinfo.exe)"
|
|
Wscript.Echo " (Process ID: " & IISPid & ")"
|
|
strShell = ShortInstallDir & "\cdb.exe -sfce -pn inetinfo.exe -c $<" & Chr(34) & CreateCDBScript(IISPid, "Inetinfo.exe") & Chr(34)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), just about to launch CDB.EXE with: " & strShell
|
|
End If
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,FALSE
|
|
Else
|
|
Wscript.echo "The '-IIS' switch was used, but IIS is not currently running."
|
|
End If
|
|
ElseIf QuickMode = true Then
|
|
If IISPid <> "" Then
|
|
PackageCount = PackageCount + 1
|
|
IISProcessCount = IISProcessCount + 1
|
|
If OSVer = "4.0" Then
|
|
Wscript.Echo "Logging debug info for: IIS (inetinfo.exe)"
|
|
Wscript.Echo " (Process ID: " & IISPid & ")"
|
|
strShell = ShortInstallDir & "\cdb.exe -sfce -pv -pn inetinfo.exe -c $<" & Chr(34) & CreateCDBScript(IISPid, "Inetinfo.exe") & Chr(34)
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,FALSE
|
|
Else
|
|
Wscript.Echo "Logging debug info for: IIS (inetinfo.exe)."
|
|
Wscript.Echo " (Process ID: " & IISPid & ")"
|
|
strShell = ShortInstallDir & "\cdb.exe -pv -pn inetinfo.exe -c $<" & Chr(34) & CreateCDBScript(IISPid, "Inetinfo.exe") & Chr(34)
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,FALSE
|
|
End If
|
|
Else
|
|
Wscript.echo "The '-IIS' switch was used, but IIS is not currently running."
|
|
End If
|
|
Else
|
|
If IISPid <> "" Then
|
|
PackageCount = PackageCount + 1
|
|
IISProcessCount = IISProcessCount + 1
|
|
Wscript.Echo "Dumping process: IIS (inetinfo.exe)"
|
|
Wscript.Echo " (Process ID: " & IISPid & ")"
|
|
strShell = ShortInstallDir & "\cdb.exe -sfce -pv -pn inetinfo.exe -c $<" & Chr(34) & CreateCDBScript(IISPid, "Inetinfo.exe") & Chr(34)
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,FALSE
|
|
Else
|
|
Wscript.echo "The '-IIS' switch was used, but IIS is not currently running."
|
|
End If
|
|
End If
|
|
|
|
'Enumerate all running MTS / COM+ server packages that are currently running and attach the debugger to them . . .
|
|
while not objTextFile.AtEndofStream
|
|
str = objTextFile.ReadLine
|
|
Str = LTrim(Str)
|
|
If InStr(Str, "Mts:") Then
|
|
arResults= split(Str,":",-1,1)
|
|
arResults(1)=trim(arResults(1))
|
|
arResults(1)=Replace(arResults(1),"/",",")
|
|
arResults(1)=Replace(arResults(1),"\",",")
|
|
arResults(1)=Replace(arResults(1),"<","(")
|
|
arResults(1)=Replace(arResults(1),">",")")
|
|
arResults(1)=Replace(arResults(1),":","")
|
|
arResults(1)=Replace(arResults(1),"*","")
|
|
arResults(1)=Replace(arResults(1),"?","")
|
|
arResults(1)=Replace(arResults(1),"|","")
|
|
arResults(0)=LTrim(arResults(0))
|
|
WheresTheSpace = InStr(arResults(0)," ")
|
|
arResults(0)= Left(arResults(0),(WheresTheSpace-1))
|
|
|
|
If DEBUGGING Then
|
|
Wscript.Echo "Enumerating all COM+ & MTS Processes from Process_List.txt"
|
|
Wscript.Echo "The Package Name is: " & arResults(1)
|
|
Wscript.echo "The Package PID is: " & arResults(0)
|
|
End if
|
|
|
|
'Dump all COM+ / MTS packages, including the system package if possible . . .
|
|
If arResults(1) <> "IIS In-Process Applications" Then 'Somtimes Inetinfo.exe shows up as "IIS In-Process Applications"
|
|
If QuickMode = true then
|
|
If OSVersion = "4.0" Then
|
|
PackageCount = PackageCount + 1
|
|
IISProcessCount = IISProcessCount + 1
|
|
Wscript.Echo "Logging debug info for: " & arResults(1)
|
|
Wscript.Echo " (Process ID: " & arResults(0) & ")"
|
|
strPackageName = Replace(Trim(arResults(1)), " ", "_")
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), strPackageName = " & strPackageName
|
|
Wscript.echo ""
|
|
End If
|
|
strShell= ShortInstallDir & "\cdb.exe -sfce -pv -p " & arResults(0) & " -c $<" & Chr(34) & CreateCDBScript(arResults(0), strPackageName) & Chr(34)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), about to run the debugger with the following string, strShell = " & strShell
|
|
Wscript.echo ""
|
|
End If
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,FALSE
|
|
Else
|
|
PackageCount = PackageCount + 1
|
|
IISProcessCount = IISProcessCount + 1
|
|
Wscript.Echo "Logging debug info for: " & arResults(1)
|
|
Wscript.Echo " (Process ID: " & arResults(0) & ")"
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), strPackageName = " & strPackageName
|
|
Wscript.echo ""
|
|
End If
|
|
strPackageName = Replace(Trim(arResults(1)), " ", "_")
|
|
strShell= ShortInstallDir & "\cdb.exe -sfce -pv -p " & arResults(0) & " -c $<" & Chr(34) & CreateCDBScript(arResults(0), strPackageName) & Chr(34)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), about to run the debugger with the following string, strShell = " & strShell
|
|
Wscript.echo ""
|
|
End If
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,FALSE
|
|
End If
|
|
|
|
ElseIf CrashMode = True Then
|
|
If OSVersion = "4.0" Then
|
|
PackageCount = PackageCount + 1
|
|
IISProcessCount = IISProcessCount + 1
|
|
Wscript.Echo "Attaching the CDB debugger to: " & arResults(1)
|
|
Wscript.Echo " (Process ID: " & arResults(0) & ")"
|
|
strPackageName = Replace(Trim(arResults(1)), " ", "_")
|
|
strPackageName = Replace(strPackageName, ",,", "-")
|
|
strPackageName = Replace(strPackageName, ",", "-")
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), strPackageName = " & strPackageName
|
|
Wscript.echo ""
|
|
End If
|
|
strShell= ShortInstallDir & "\cdb.exe -sfce -p " & arResults(0) & " -c $<" & Chr(34) & CreateCDBScript(arResults(0), strPackageName) & Chr(34)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), about to run the debugger with the following string, strShell = " & strShell
|
|
Wscript.echo ""
|
|
End If
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,FALSE
|
|
Else
|
|
PackageCount = PackageCount + 1
|
|
IISProcessCount = IISProcessCount + 1
|
|
Wscript.Echo "Attaching the CDB debugger to: " & arResults(1)
|
|
Wscript.Echo " (Process ID: " & arResults(0) & ")"
|
|
strPackageName = Replace(Trim(arResults(1)), " ", "_")
|
|
strPackageName = Replace(strPackageName, ",,", "-")
|
|
strPackageName = Replace(strPackageName, ",", "-")
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), strPackageName = " & strPackageName
|
|
Wscript.echo ""
|
|
End If
|
|
strShell= ShortInstallDir & "\cdb.exe -sfce -p " & arResults(0) & " -c $<" & Chr(34) & CreateCDBScript(arResults(0), strPackageName) & Chr(34)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), about to run the debugger with the following string, strShell = " & strShell
|
|
Wscript.echo ""
|
|
End If
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,FALSE
|
|
End If
|
|
Else
|
|
PackageCount = PackageCount + 1
|
|
IISProcessCount = IISProcessCount + 1
|
|
Wscript.Echo "Dumping process: " & arResults(1)
|
|
Wscript.Echo " (Process ID: " & arResults(0) & ")"
|
|
strPackageName = Replace(Trim(arResults(1)), " ", "_")
|
|
strPackageName = Replace(strPackageName, ",,", "-")
|
|
strPackageName = Replace(strPackageName, ",", "-")
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), strPackageName = " & strPackageName
|
|
Wscript.echo ""
|
|
End If
|
|
strShell= ShortInstallDir & "\cdb.exe -sfce -pv -p " & arResults(0) & " -c $<" & Chr(34) & CreateCDBScript(arResults(0), strPackageName) & Chr(34)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpIIS(), about to run the debugger with the following string, strShell = " & strShell
|
|
Wscript.echo ""
|
|
End If
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,FALSE
|
|
End If
|
|
End If
|
|
End if
|
|
|
|
wend
|
|
|
|
Else
|
|
If QuietMode = False Then
|
|
objshell.popup "The command 'tlist.exe -k' does not appear to have run properly from the " & InstallDir & " directory. AutodumpPlus can not continue.",,"AutodumpPlus",0
|
|
ErrorsDuringRuntime = True
|
|
Else
|
|
objShell.LogEvent 1, "The command 'tlist.exe -k' does not appear to have run properly from the " & InstallDir & " directory. AutodumpPlus can not continue."
|
|
wscript.echo "The command 'tlist.exe -k' does not appear to have run properly from the " & InstallDir & " directory. AutodumpPlus can not continue."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
Wscript.quit 1
|
|
|
|
End if
|
|
|
|
objTextFile.Close
|
|
Set objTextFile = nothing
|
|
Set objFileSystem = nothing
|
|
Set objShell = nothing
|
|
|
|
End sub
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: DumpAnyProc
|
|
' This is the code used to dump any processes specified on the command line.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub DumpAnyProc()
|
|
On Error Resume Next
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the DumpAnyProc function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
Dim objFileSystem
|
|
Dim objTextFile
|
|
Dim Str
|
|
Dim i
|
|
Dim x,y
|
|
Dim LineNumber
|
|
Dim args
|
|
Dim PIDArgItems
|
|
Dim PidArgItemsCount
|
|
Dim ProcArgItems
|
|
Dim ProcArgItemsCount
|
|
Dim arResults
|
|
Dim objShell
|
|
Dim strShell
|
|
Dim versionFile
|
|
Dim TempCounter
|
|
Dim strPackageName
|
|
Dim strProcName
|
|
Dim PidMatch
|
|
Dim ProcessMatch
|
|
Dim ProcNamePidArray()
|
|
Dim FirstCall
|
|
|
|
FirstCall = True
|
|
LineNumber = 1
|
|
PidMatch = false
|
|
ProcessMatch = false
|
|
x = 0
|
|
Set objFileSystem = CreateObject("Scripting.FileSystemObject")
|
|
Set objShell = CreateObject("Wscript.Shell")
|
|
|
|
'Per the scripting team's advice, sleep for .5 second prior to calling this function.
|
|
Wscript.sleep 500
|
|
If CrashMode = true Then
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpAnyProc(), The Process_List.txt file should be located here: " & CrashDir & "\Process_List.txt"
|
|
Wscript.echo ""
|
|
End If
|
|
While not objFileSystem.FileExists(CrashDir & "\Process_List.txt")
|
|
Wscript.sleep 1000
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc(), The Process_List.txt file has not been created yet, sleeping for 1 second and trying again."
|
|
wscript.echo ""
|
|
End If
|
|
i = i +1
|
|
If i = 10 Then
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc(), Could not find the Process_List.txt file in the folder: " & CrashDir
|
|
wscript.echo "In DumpAnyProc(), Exiting AutodumpPlus now."
|
|
wscript.echo ""
|
|
End If
|
|
If QuietMode = False Then
|
|
objShell.PopUp "The file Process_List.txt could not be found in the " & CrashDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "The file Process_List.txt could not be found in the " & CrashDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
objShell.LogEvent 1, "The file Process_List.txt could not be found in the " & CrashDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
If HangMode = True Then
|
|
DeleteDirectory(HangDir)
|
|
Else
|
|
DeleteDirectory(CrashDir)
|
|
End If
|
|
|
|
wscript.quit 1
|
|
End If
|
|
|
|
Wend
|
|
Else 'Running in Hang or Quick modes . . .
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpAnyProc(), The Process_List.txt file should be located here: " & HangDir & "\Process_List.txt"
|
|
End If
|
|
While not objFileSystem.FileExists(HangDir & "\Process_List.txt")
|
|
Wscript.sleep 1000
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc(), The Process_List.txt file has not been created yet, sleeping for 1 second and trying again."
|
|
wscript.echo ""
|
|
End If
|
|
i = i +1
|
|
If i = 10 Then
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc(), Could not find the Process_List.txt file in the folder: " & HangDir
|
|
wscript.echo "In DumpAnyProc(), Exiting AutodumpPlus now."
|
|
wscript.echo ""
|
|
End If
|
|
If QuietMode = False Then
|
|
objShell.PopUp "The file Process_List.txt could not be found in the " & HangDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "The file Process_List.txt could not be found in the " & HangDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
objShell.LogEvent 1, "The file Process_List.txt could not be found in the " & HangDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
If HangMode = True Then
|
|
DeleteDirectory(HangDir)
|
|
Else
|
|
DeleteDirectory(CrashDir)
|
|
End If
|
|
|
|
wscript.quit 1
|
|
End If
|
|
|
|
Wend
|
|
End If
|
|
|
|
If HangMode = True Then
|
|
Set objTextFile = objFileSystem.OpenTextFile(HangDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
Else
|
|
Set objTextFile = objFileSystem.OpenTextFile(CrashDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
End If
|
|
i = 0
|
|
While objTextFile.AtEndOfStream
|
|
'Close the text file to let it finish writing and to get a new copy . . .
|
|
objTextFile.Close
|
|
wscript.sleep 1000
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc(), Waiting for Process_List.txt to finish writing (sleeping 1 second). . . "
|
|
wscript.echo ""
|
|
End If
|
|
i = i +1
|
|
If i = 10 Then
|
|
If HangMode = True Then
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc(), Process_List.txt was never closed (finished writing) in the folder: " & HangDir
|
|
wscript.echo "In DumpAnyProc(), Exiting AutodumpPlus now."
|
|
wscript.echo ""
|
|
End If
|
|
If QuietMode = False Then
|
|
objShell.PopUp "The file Process_List.txt was never closed (finished writing) by tlist.exe in the " & HangDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "The file Process_List.txt was never closed (finished writing) by tlist.exe in the " & HangDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
objShell.LogEvent 1, "The file Process_List.txt was never closed (finished writing) by tlist.exe in the " & HangDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
DeleteDirectory(HangDir)
|
|
wscript.quit 1
|
|
Else
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc(), Process_List.txt was never closed (finished writing) in the folder: " & CrashDir
|
|
wscript.echo "In DumpAnyProc(), Exiting AutodumpPlus now."
|
|
wscript.echo ""
|
|
End If
|
|
If QuietMode = False Then
|
|
objShell.PopUp "The file Process_List.txt was never closed (finished writing) by tlist.exe in the " & CrashDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
Else
|
|
Wscript.echo "The file Process_List.txt was never closed (finished writing) by tlist.exe in the " & CrashDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
objShell.LogEvent 1, "The file Process_List.txt was never closed (finished writing) by tlist.exe in the " & CrashDir & " directory after waiting for 10 seconds. This could indicate that there was a problem running tlist.exe or that the file could not be read using the Scripting.FileSystemObject. Please try running tlist.exe manually from the " & installdir & " directory or re-register scrrun.dll and try running AutodumpPlus again."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
DeleteDirectory(CrashDir)
|
|
wscript.quit 1
|
|
End If
|
|
End If
|
|
'Open the text file again before looping . . .
|
|
If HangMode = True Then
|
|
Set objTextFile = objFileSystem.OpenTextFile(HangDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
Else
|
|
Set objTextFile = objFileSystem.OpenTextFile(CrashDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
End If
|
|
|
|
Wend
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
If IISMode = False then
|
|
If HangMode = true and QuickMode = true Then
|
|
Wscript.Echo "The '-quick' switch was used, AutodumpPlus is running in 'quick hang' mode."
|
|
ElseIf HangMode = true Then
|
|
Wscript.echo "The '-hang' switch was used, AutodumpPlus is running in 'hang' mode."
|
|
End If
|
|
|
|
If CrashMode = true Then
|
|
Wscript.Echo "The '-crash' switch was used, AutodumpPlus is running in 'crash' mode."
|
|
End If
|
|
|
|
If QuietMode = true Then
|
|
Wscript.Echo "The '-quiet' switch was used, AutodumpPlus will not display any modal dialog boxes."
|
|
End If
|
|
|
|
If OSwitchUsed = true Then
|
|
Wscript.Echo "The '-o' switch was used. AutodumpPlus will place all files in"
|
|
Wscript.echo "the following directory: " & OutputDir
|
|
End If
|
|
|
|
If NotifyAdmin = true Then
|
|
Wscript.Echo "The '-notify' switch was used. AutodumpPlus will send notification to"
|
|
Wscript.echo "the following computer or user: " & NotifyTarget
|
|
End If
|
|
|
|
End If
|
|
|
|
If GenericModePID = True Then
|
|
PidArgItems = GenericProcessPIDDictionary.Items
|
|
PidArgItemsCount = GenericProcessPIDDictionary.Count
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc, in the function to get the process name, given the '-p' switch."
|
|
wscript.echo ""
|
|
End If
|
|
|
|
For i = 0 to PidArgItemsCount -1
|
|
If HangMode = True Then
|
|
Set objTextFile = objFileSystem.OpenTextFile(HangDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
Else
|
|
Set objTextFile = objFileSystem.OpenTextFile(CrashDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
End If
|
|
|
|
While not objTextFile.AtEndofStream
|
|
str = objTextFile.ReadLine
|
|
Str = LTrim(Str)
|
|
arResults= split(Str," ",-1,1)
|
|
arResults(1)=trim(arResults(1))
|
|
arResults(1)=Replace(arResults(1),"/",",")
|
|
arResults(1)=Replace(arResults(1),"\",",")
|
|
arResults(1)=Replace(arResults(1),"<","(")
|
|
arResults(1)=Replace(arResults(1),">",")")
|
|
arResults(1)=Replace(arResults(1),":","")
|
|
arResults(1)=Replace(arResults(1),"*","")
|
|
arResults(1)=Replace(arResults(1),"?","")
|
|
arResults(1)=Replace(arResults(1),"|","")
|
|
|
|
|
|
If Trim(arResults(0)) = PidArgItems(i) Then
|
|
PidMatch = True
|
|
strProcName = Trim(arResults(1))
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc(), Logging debug info for: Process - " & strProcName & " with PID - " & PidArgItems(i)
|
|
wscript.echo ""
|
|
End If
|
|
End If
|
|
Wend
|
|
If CrashMode = True Then
|
|
strShell= ShortInstallDir & "\cdb.exe -sfce -p " & PidArgItems(i) & " -c $<" & Chr(34) & CreateCDBScript(PidArgItems(i), strProcName) & Chr(34)
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc(), running in CrashMode, strShell = " & strShell
|
|
wscript.echo ""
|
|
End If
|
|
|
|
Else
|
|
strShell= ShortInstallDir & "\cdb.exe -sfce -pv -p " & PidArgItems(i) & " -c $<" & Chr(34) & CreateCDBScript(PidArgItems(i), strProcName) & Chr(34)
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc(), running in Hang or Quick mode, strShell = " & strShell
|
|
wscript.echo ""
|
|
End If
|
|
|
|
End If
|
|
If PidMatch = True Then
|
|
If FirstCall = True Then
|
|
If CrashMode = True Then
|
|
Wscript.echo ""
|
|
Wscript.echo "Monitoring the processes that were specified"
|
|
Wscript.echo "on the command line for unhandled exceptions."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
ElseIf QuickMode = True Then
|
|
Wscript.echo ""
|
|
Wscript.echo "Logging debug info for the processes that were"
|
|
Wscript.echo "specified on the command line."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
Else
|
|
Wscript.echo ""
|
|
Wscript.echo "Dumping process information for the processes"
|
|
Wscript.echo "that were specified on the command line."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
End If
|
|
End If
|
|
|
|
FirstCall = False
|
|
If CrashMode = True Then
|
|
wscript.echo "Attaching the CDB debugger to: Process - " & strProcName & " with PID - " & PidArgItems(i)
|
|
ElseIf QuickMode = True Then
|
|
wscript.echo "Logging debug info for: Process - " & strProcName & " with PID - " & PidArgItems(i)
|
|
Else
|
|
wscript.echo "Dumping Process: " & strProcName & " with PID - " & PidArgItems(i)
|
|
End If
|
|
'Now run the debugger . . .
|
|
If PackageCount < MAX_APPLICATIONS_TO_DEBUG Then
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,FALSE
|
|
Else
|
|
wscript.echo "MAX_APPLICATIONS_TO_DEBUG has been exceeded, skipping the above process . . ."
|
|
End If
|
|
PackageCount = PackageCount + 1
|
|
|
|
Else
|
|
If QuietMode = False Then
|
|
objShell.PopUp "One or more process ID's specified on the command line using the '-p' switch, were not found. Please doublecheck the process ID(s) and run AutodumpPlus again.",,"AutodumpPlus",0
|
|
ErrorsDuringRuntime = True
|
|
Else
|
|
objShell.LogEvent 1, "One or more process ID's specified on the command line using the '-p' switch, were not found. Please doublecheck the process ID(s) and run AutodumpPlus again."
|
|
wscript.echo "One or more process ID's specified on the command line using the '-p' switch, were not found. Please doublecheck the process ID(s) and run AutodumpPlus again."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
objTextFile.Close
|
|
If HangMode = True Then
|
|
DeleteDirectory(HangDir)
|
|
Else
|
|
DeleteDirectory(CrashDir)
|
|
End If
|
|
Wscript.quit 1
|
|
End If
|
|
Next
|
|
|
|
End If
|
|
|
|
If GenericModeProcessName = true Then
|
|
ProcArgItems = GenericProcessNameDictionary.Items 'Store the GenericProcessNameDictionary items collection in an array
|
|
ProcArgItemsCount = GenericProcessNameDictionary.Count 'Get the count of all the items in the array
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DumpAnyProc, in the function to get the process ID, given the '-pn' switch."
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
For i = 0 to ProcArgItemsCount -1
|
|
x = 0
|
|
|
|
If HangMode = True Then
|
|
Set objTextFile = objFileSystem.OpenTextFile(HangDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
Else
|
|
Set objTextFile = objFileSystem.OpenTextFile(CrashDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
End If
|
|
While not objTextFile.AtEndofStream
|
|
str = objTextFile.ReadLine
|
|
Str = LTrim(Str)
|
|
arResults= split(Str," ",-1,1)
|
|
arResults(1)=trim(arResults(1))
|
|
arResults(1)=Replace(arResults(1),"/",",")
|
|
arResults(1)=Replace(arResults(1),"\",",")
|
|
arResults(1)=Replace(arResults(1),"<","(")
|
|
arResults(1)=Replace(arResults(1),">",")")
|
|
arResults(1)=Replace(arResults(1),":","")
|
|
arResults(1)=Replace(arResults(1),"*","")
|
|
arResults(1)=Replace(arResults(1),"?","")
|
|
arResults(1)=Replace(arResults(1),"|","")
|
|
If UCase(arResults(1)) = UCase(ProcArgItems(i)) Then
|
|
ProcessMatch = True
|
|
x = x + 1
|
|
End If
|
|
Wend
|
|
objTextFile.Close
|
|
|
|
'If the process name specified is invalid, display an error and then quit.
|
|
If ProcessMatch = False Then
|
|
If QuietMode = False Then
|
|
objShell.PopUp "One or more process names specified on the command line using the '-pn' switch, were not found. Please doublecheck the process name(s) and run AutodumpPlus again.",,"AutodumpPlus",0
|
|
ErrorsDuringRuntime = True
|
|
Else
|
|
objShell.LogEvent 1, "One or more process names specified on the command line using the '-pn' switch, were not found. Please doublecheck the process name(s) and run AutodumpPlus again."
|
|
wscript.echo "One or more process names specified on the command line using the '-pn' switch, were not found. Please doublecheck the process name(s) and run AutodumpPlus again."
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
|
|
'If there was nothing to dump or log, then display an error and clean up the directory
|
|
If IISMode = False Then
|
|
If HangMode = True Then
|
|
'Wscript.echo HangDir
|
|
DeleteDirectory(HangDir)
|
|
Else
|
|
'Wscript.echo CrashDir
|
|
DeleteDirectory(CrashDir)
|
|
End If
|
|
Wscript.quit 1
|
|
End If
|
|
End If
|
|
|
|
ReDim ProcNamePidArray(x)
|
|
x = 0
|
|
|
|
|
|
If HangMode = True Then
|
|
Set objTextFile = objFileSystem.OpenTextFile(HangDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
Else
|
|
Set objTextFile = objFileSystem.OpenTextFile(CrashDir & "\Process_List.txt",ForReading,TristateUseDefault)
|
|
End If
|
|
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc, in GenericModeProcessName function."
|
|
wscript.echo ""
|
|
End If
|
|
|
|
If objTextFile.AtEndOfStream Then
|
|
wscript.echo "objTextFile is at EndOfStream"
|
|
wscript.echo ""
|
|
End If
|
|
|
|
While not objTextFile.AtEndofStream
|
|
str = objTextFile.ReadLine
|
|
Str = LTrim(Str)
|
|
arResults= split(Str," ",-1,1)
|
|
arResults(1)=trim(arResults(1))
|
|
arResults(1)=Replace(arResults(1)," ",",")
|
|
If UCase(arResults(1)) = UCase(ProcArgItems(i)) Then
|
|
ProcNamePidArray(x) = Trim(arResults(0))
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc(), ProcNamePidArray(x) = " & ProcNamePidArray(x)
|
|
wscript.echo ""
|
|
End If
|
|
|
|
x = x + 1
|
|
End If
|
|
|
|
Wend
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In DumpAnyProc(), Total number of CDB sessions to launch: " & UBound(ProcNamePidArray, 1)
|
|
wscript.echo ""
|
|
End If
|
|
For y = 0 to UBound(ProcNamePidArray, 1) - 1 'The For . . . Each syntax seemed to have an extra, empty array element which was causing problems
|
|
If DEBUGGING = True Then
|
|
Wscript.echo ""
|
|
Wscript.echo "In the DumpAnyProc(), PID = " & ProcNamePidArray(y)
|
|
End If
|
|
If CrashMode = true Then
|
|
strShell= ShortInstallDir & "\cdb.exe -sfce -p " & ProcNamePidArray(y) & " -c $<" & Chr(34) & CreateCDBScript(ProcNamePidArray(y), Trim(UCase(ProcArgItems(i)))) & Chr(34)
|
|
If DEBUGGING = True Then
|
|
Wscript.echo "In the DumpAnyProc(), strShell = " & strShell
|
|
Wscript.echo ""
|
|
End If
|
|
Else
|
|
strShell= ShortInstallDir & "\cdb.exe -sfce -pv -p " & ProcNamePidArray(y) & " -c $<" & Chr(34) & CreateCDBScript(ProcNamePidArray(y), Trim(UCase(ProcArgItems(i)))) & Chr(34)
|
|
If DEBUGGING = True Then
|
|
Wscript.echo "In the DumpAnyProc(), strShell = " & strShell
|
|
Wscript.echo ""
|
|
End If
|
|
End If
|
|
|
|
If FirstCall = True Then
|
|
If CrashMode = True Then
|
|
Wscript.echo ""
|
|
Wscript.echo "Monitoring the processes that were specified on the command line"
|
|
Wscript.echo "for unhandled exceptions."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
ElseIf QuickMode = True Then
|
|
Wscript.echo ""
|
|
Wscript.echo "Logging debug info for the processes that were specified on the command line."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
Else
|
|
Wscript.echo ""
|
|
Wscript.echo "Dumping process information for the processes that were specified"
|
|
Wscript.echo "on the command line."
|
|
Wscript.echo "----------------------------------------------------------------------"
|
|
End If
|
|
End If
|
|
FirstCall = False
|
|
|
|
If CrashMode = true Then
|
|
wscript.echo "Attaching the CDB debugger to: Process - " & Trim(UCase(ProcArgItems(i))) & " with PID - " & ProcNamePidArray(y)
|
|
ElseIf QuickMode = true Then
|
|
wscript.echo "Logging debug info for: Process - " & Trim(UCase(ProcArgItems(i))) & " with PID - " & ProcNamePidArray(y)
|
|
Else
|
|
wscript.echo "Dumping Process: " & Trim(UCase(ProcArgItems(i))) & " with PID - " & ProcNamePidArray(y)
|
|
End If
|
|
If PackageCount < MAX_APPLICATIONS_TO_DEBUG Then
|
|
objShell.Run strShell,MINIMIZE_NOACTIVATE,FALSE
|
|
Else
|
|
wscript.echo "MAX_APPLICATIONS_TO_DEBUG has been exceeded, skipping the above process . . ."
|
|
End If
|
|
PackageCount = PackageCount + 1
|
|
' objShell.Run strShell,MINIMIZE_NOACTIVATE,FALSE
|
|
|
|
Next
|
|
|
|
Next
|
|
|
|
End If
|
|
|
|
End Sub
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: ShowStatus
|
|
' This is the code used to display the pop-up summary at the end of AutodumpPlus.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub ShowStatus(OSVersion)
|
|
On Error Resume Next
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the ShowStatus() function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
Dim objFileSystem
|
|
Dim versionFile
|
|
Set objFileSystem = CreateObject("Scripting.FileSystemObject")
|
|
|
|
If PackageCount = 1 Then
|
|
If QuickMode = true Then
|
|
If OSVersion = "4.0" Then
|
|
If QuietMode = False Then
|
|
objshell.popup "AutodumpPlus is now running in 'quick' mode and is logging information for all of the threads in the process you have chosen to examine. Quick mode is usually faster than 'hang' mode, however you may still see " & PackageCount & " minimized command shell window which is logging information about this process. AutodumpPlus is finished running when this window disappears. After AutodumpPlus completes, please check the " & HangDir & " directory to verify the log file for this process was created!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 0, "AutodumpPlus is now running in 'quick' mode with the '-quiet' switch, and was started at: " & DateTimeStamp & "."
|
|
End If
|
|
Else
|
|
If QuietMode = False Then
|
|
objshell.popup "AutodumpPlus is now running in 'quick' mode and is logging information for all of the threads in the process you have chosen to examine. Quick mode is usually faster than 'hang' mode, however you may still see " & PackageCount & " minimized command shell window which is logging information about this process. AutodumpPlus is finished running when this window disappears. After AutodumpPlus completes, please check the " & HangDir & " directory to verify the log file for this process was created!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 0, "AutodumpPlus is now running in 'quick' mode with the '-quiet' switch, and was started at: " & DateTimeStamp & "."
|
|
End If
|
|
End If
|
|
ElseIf CrashMode = True Then
|
|
If OSVersion = "4.0" Then
|
|
If QuietMode = False Then
|
|
objshell.popup "AutodumpPlus is now running in 'crash' mode and has attached the CDB debugger to the process you have chosen to monitor for crashes. You should see " & PackageCount & " minimized debugger window which is monitoring this process for any exceptions. A log file will be generated for the process you have chosen to monitor and when a 1st chance exception occurs, it will be logged to this log file and a mini-memory dump will be produced. If a 2nd chance exception occurs, it will be logged to this log file and a full memory dump will be produced. AutodumpPlus has probably captured a crash if and when the minimized debugger window disappears. If the process hangs while running in crash mode, or if you wish to stop debugging the process, please press CTRL-C in the minimized debugger window to stop debugging, and then re-start the process if necessary. After AutodumpPlus completes, please check the " & CrashDir & " directory to verify log files and possibly memory dump files for this process were created!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 0, "AutodumpPlus is now running in 'crash' mode with the '-quiet' switch, and was started at: " & DateTimeStamp & "."
|
|
End If
|
|
Else
|
|
If QuietMode = False Then
|
|
objshell.popup "AutodumpPlus is now running in 'crash' mode and has attached the CDB debugger to the process you have chosen to monitor for crashes. You should see " & PackageCount & " minimized debugger window which is monitoring this process for any exceptions. A log file will be generated for the process you have chosen to monitor and when a 1st chance exception occurs, it will be logged to this log file and a mini-memory dump will be produced. If a 2nd chance exception occurs, it will be logged to this log file and a full memory dump will be produced. AutodumpPlus has probably captured a crash if and when the minimized debugger window disappears. If the process hangs while running in crash mode, or if you wish to stop debugging the process, please press CTRL-C in the minimized debugger window to stop debugging, and then re-start the process if necessary. After AutodumpPlus completes, please check the " & CrashDir & " directory to verify log files and possibly memory dump files for this process were created!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 0, "AutodumpPlus is now running in 'crash' mode with the '-quiet' switch, and was started at: " & DateTimeStamp & "."
|
|
End If
|
|
End If
|
|
Else
|
|
If OSVersion = "4.0" Then
|
|
If QuietMode = False Then
|
|
objshell.popup "AutodumpPlus is now dumping the process you have chosen to examine. Depending upon the size of the process being dumped, AutodumpPlus could take anywhere from a few seconds to a few minutes to complete. You should see " & PackageCount & " minimized command shell window which is dumping the process. AutodumpPlus is finished when this window disappears. After AutodumpPlus completes, please check the " & HangDir & " directory to verify the memory dump was created!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 0, "AutodumpPlus is now running in 'hang' mode with the '-quiet' switch, and was started at: " & DateTimeStamp & "."
|
|
End If
|
|
Else
|
|
If QuietMode = False Then
|
|
objshell.popup "AutodumpPlus is now dumping the process you have chosen to examine. Depending upon the size of the process being dumped, AutodumpPlus could take anywhere from a few seconds to a few minutes to complete. You should see " & PackageCount & " minimized command shell window which is dumping the process. AutodumpPlus is finished when this window disappears. After AutodumpPlus completes, please check the " & HangDir & " directory to verify the memory dump was created!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 0, "AutodumpPlus is now running in 'hang' mode with the '-quiet' switch, and was started at: " & DateTimeStamp & "."
|
|
End If
|
|
End If
|
|
End If
|
|
ElseIf PackageCount > 0 Then
|
|
If QuickMode = true Then
|
|
If OSVersion = "4.0" Then
|
|
If QuietMode = False Then
|
|
objshell.popup "AutodumpPlus is now running in 'quick' mode and is logging information for all of the threads in the processes you have chosen to examine. Quick mode is usually faster than 'hang' mode, however you may still see at least " & PackageCount & " minimized command shell windows which are logging information about these processes. AutodumpPlus is finished running when these windows disappear. After AutodumpPlus completes, please check the " & HangDir & " directory to verify the log files for each process were created!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 0, "AutodumpPlus is now running in 'quick' mode with the '-quiet' switch, and was started at: " & DateTimeStamp & "."
|
|
End If
|
|
Else
|
|
If QuietMode = False Then
|
|
objshell.popup "AutodumpPlus is now running in 'quick' mode and is logging information for all of the threads in the processes you have chosen to examine. Quick mode is usually faster than 'hang' mode, however you may still see at least " & PackageCount & " minimized command shell windows which are logging information about these processes. AutodumpPlus is finished running when these windows disappear. After AutodumpPlus completes, please check the " & HangDir & " directory to verify the log files for each process were created!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 0, "AutodumpPlus is now running in 'quick' mode with the '-quiet' switch, and was started at: " & DateTimeStamp & "."
|
|
End If
|
|
End If
|
|
ElseIf CrashMode = true Then
|
|
If OSVersion = "4.0" Then
|
|
If QuietMode = False Then
|
|
objshell.popup "AutodumpPlus is now running in 'crash' mode and has attached the CDB debugger to the processes you have chosen to monitor for crashes. You should see " & PackageCount & " minimized debugger windows which are monitoring these processes for any exceptions. A log file will be generated for each process you have chosen to monitor and when a 1st chance exception occurs, it will be logged to this log file and a mini-memory dump will be produced. If a 2nd chance exception occurs, it will be logged to this log file and a full memory dump will be produced. AutodumpPlus has probably captured a crash if and when any of these minimized debugger windows disappear. If any of these processes hang while running in crash mode, or if you wish to stop debugging a process that has not crashed, please press CTRL-C in ALL minimized debugger windows to stop debugging, and then re-start the processes if necessary. After AutodumpPlus completes, please check the " & CrashDir & " directory to verify log files and possibly memory dump files for these processes were created!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 0, "AutodumpPlus is now running in 'crash' mode with the '-quiet' switch, and was started at: " & DateTimeStamp & "."
|
|
End If
|
|
Else
|
|
If QuietMode = False Then
|
|
objshell.popup "AutodumpPlus is now running in 'crash' mode and has attached the CDB debugger to the processes you have chosen to monitor for crashes. You should see " & PackageCount & " minimized debugger windows which are monitoring these processes for any exceptions. A log file will be generated for each process you have chosen to monitor and when a 1st chance exception occurs, it will be logged to this log file and a mini-memory dump will be produced. If a 2nd chance exception occurs, it will be logged to this log file and a full memory dump will be produced. AutodumpPlus has probably captured a crash if and when any of these minimized debugger windows disappear. If any of these processes hang while running in crash mode, or if you wish to stop debugging a process that has not crashed, please press CTRL-C in ALL minimized debugger windows to stop debugging, and then re-start the processes if necessary. After AutodumpPlus completes, please check the " & CrashDir & " directory to verify log files and possibly memory dump files for these processes were created!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 0, "AutodumpPlus is now running in 'crash' mode with the '-quiet' switch, and was started at: " & DateTimeStamp & "."
|
|
End If
|
|
End If
|
|
Else
|
|
If OSVersion = "4.0" Then
|
|
If QuietMode = False Then
|
|
objshell.popup "AutodumpPlus is now dumping the processes you have chosen to examine. Depending upon the number of processes being dumped, AutodumpPlus could take anywhere from a few seconds to a few minutes to complete. You should see at least " & PackageCount & " minimized command shell windows which are dumping processes. AutodumpPlus is finished dumping processes when these windows disappear. After AutodumpPlus completes, please check the " & HangDir & " directory to verify the memory dumps were created!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 0, "AutodumpPlus is now running in 'hang' mode with the '-quiet' switch, and was started at: " & DateTimeStamp & "."
|
|
End If
|
|
Else
|
|
If QuietMode = False Then
|
|
objshell.popup "AutodumpPlus is now dumping the processes you have chosen to examine. Depending upon the number of processes being dumped, AutodumpPlus could take anywhere from a few seconds to a few minutes to complete. You should see at least " & PackageCount & " minimized command shell windows which are dumping processes. AutodumpPlus is finished dumping processes when these windows disappear. After AutodumpPlus completes, please check the " & HangDir & " directory to verify the memory dumps were created!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 0, "AutodumpPlus is now running in 'hang' mode with the '-quiet' switch, and was started at: " & DateTimeStamp & "."
|
|
End If
|
|
End If
|
|
End If
|
|
Else
|
|
'There were no processes to dump based on the specified command line criteria, display an error and quit.
|
|
If QuietMode = False Then
|
|
objshell.popup "There were no processes found to examine based on the parameters specified on the command line. If the '-iis' switch was used, please ensure that IIS is running. If the '-pn' or '-p' switches were used, please ensure you typed the process name correctly or that you specified the right Process ID.",,"AutodumpPlus",0
|
|
Else
|
|
wscript.echo "There were no processes found to examine based on the parameters specified on the command line. If the '-iis' switch was used, please ensure that IIS is running. If the '-pn' or '-p' switches were used, please ensure you typed the process name correctly or that you specified the right Process ID."
|
|
objShell.LogEvent 0, "There were no processes found to examine based on the parameters specified on the command line. If the '-iis' switch was used, please ensure that IIS is running. If the '-pn' or '-p' switches were used, please ensure you typed the process name correctly or that you specified the right Process ID."
|
|
End If
|
|
|
|
'Clean up the directory since no output was produced.
|
|
If Crashmode = true Then
|
|
DeleteDirectory(CrashDir)
|
|
Else
|
|
DeleteDirectory(HangDir)
|
|
End If
|
|
|
|
Wscript.quit 1
|
|
|
|
End If
|
|
|
|
If CrashMode = true Then
|
|
err.clear
|
|
Set versionFile = objFileSystem.CreateTextFile(CrashDir & "\AutodumpPlus-report.txt",True)
|
|
If Err.number <> 0 Then
|
|
wscript.echo "Error encountered creating AutodumpPlus-report.txt"
|
|
wscript.echo "Error Description: " & err.description
|
|
wscript.echo "Error Number: " & err.number
|
|
End If
|
|
Else
|
|
err.clear
|
|
Set versionFile = objFileSystem.CreateTextFile(HangDir & "\AutodumpPlus-report.txt",True)
|
|
If Err.number <> 0 Then
|
|
wscript.echo "Error encountered creating AutodumpPlus-report.txt"
|
|
wscript.echo "Error Description: " & err.description
|
|
wscript.echo "Error Number: " & err.number
|
|
End If
|
|
End If
|
|
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In ShowStatus(), about to create AutodumpPlus-report.txt"
|
|
wscript.echo ""
|
|
End If
|
|
|
|
versionFile.writeline "'********************************************************************"
|
|
versionFile.writeline "'* File: AutodumpPlus-report.txt"
|
|
versionFile.writeline "'* AutodumpPlus version: " & VERSION
|
|
versionFile.writeline "'* Debuggers Installation Directory: " & InstallDir
|
|
versionFile.writeline "'* AutodumpPlus was run on: " & ComputerName
|
|
If HangMode = True Then
|
|
versionFile.writeline "'* Output Directory: " & HangDir
|
|
Else
|
|
versionFile.writeline "'* Output Directory: " & CrashDir
|
|
End If
|
|
If OSVer = "4.0" Then
|
|
versionFile.writeline "'* AutodumpPlus was run on NT 4.0."
|
|
Else
|
|
versionFile.writeline "'* AutodumpPlus was run on Windows 2000 or higher."
|
|
End If
|
|
If HangMode = True Then
|
|
versionFile.writeline "'* AutodumpPlus was run with the '-hang' switch."
|
|
End If
|
|
If QuickMode = true Then
|
|
versionFile.writeline "'* AutodumpPlus was run with the '-quick' switch."
|
|
End If
|
|
If CrashMode = true Then
|
|
versionFile.writeline "'* AutodumpPlus was run with the '-crash' switch."
|
|
End If
|
|
If PageHeapMode = true Then
|
|
versionFile.writeline "'* AutodumpPlus was run with the '-pageheap' switch."
|
|
End If
|
|
If QuietMode = true Then
|
|
versionFile.writeline "'* AutodumpPlus was run with the '-quiet' switch."
|
|
End If
|
|
If IISMode = True Then
|
|
versionFile.writeline "'* AutodumpPlus was run with the '-IIS' switch."
|
|
versionFile.writeline "'* IIS version: " & IISVer
|
|
End If
|
|
versionFile.writeline "'*"
|
|
versionFile.writeline "'* AutodumpPlus's constants had the following values:"
|
|
versionFile.writeline "'* DEBUGGING = " & DEBUGGING
|
|
versionFile.writeline "'* Full_Dump_on_CONTRL_C = " & Full_Dump_on_CONTRL_C
|
|
versionFile.writeline "'* Create_Full_Dump_on_1st_Chance_Exception = " & Create_Full_Dump_on_1st_Chance_Exception
|
|
versionFile.writeline "'* No_Dump_on_1st_Chance_Exception = " & No_Dump_on_1st_Chance_Exception
|
|
versionFile.writeline "'* Dump_on_EH_Exceptions = " & Dump_on_EH_Exceptions
|
|
versionFile.writeline "'* Dump_on_Unknown_Exceptions = " & Dump_on_Unknown_Exceptions
|
|
versionFile.writeline "'* Dump_Stack_on_DLL_Load = " & Dump_Stack_on_DLL_Load
|
|
versionFile.writeline "'* Dump_Stack_on_DLL_UnLoad = " & Dump_Stack_on_DLL_UnLoad
|
|
versionFile.writeline "'* No_CrashMode_Log = " & No_CrashMode_Log
|
|
versionFile.writeline "'* No_Free_Space_Checking = " & No_Free_Space_Checking
|
|
versionFile.writeline "'* "
|
|
versionFile.writeline "'* Date & Time AutodumpPlus was run: " & Now
|
|
If ErrorsDuringRuntime = True Then
|
|
versionFile.writeline "Error and warning information:"
|
|
versionFile.writeline "AutodumpPlus encountered one or more errors or warnings. Please check the event log for more information."
|
|
End If
|
|
If SymPathError = True Then
|
|
versionFile.writeline "'* WARNING! An '_NT_SYMBOL_PATH' environment variable is not set, as a result AutodumpPlus will be forced to use 'export' symbols (if present) to resolve function names in the stack trace information for each thread listed in the log file for the processes being debugged. To resolve this warning, please copy the appropriate symbols to a directory on the server and then create an environment variable with a name of '_NT_SYMBOL_PATH' and a value containing the path to the proper symbols (i.e. c:\winnt\symbols) before running AutodumpPlus in quick or crash modes again. NOTE: After creating the '_NT_SYMBOL_PATH' system environment variable you will need to close the current command shell and open a new one before running AutodumpPlus again."
|
|
End If
|
|
versionFile.writeline "'********************************************************************"
|
|
versionFile.close
|
|
|
|
End Sub
|
|
|
|
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: PrintHelp
|
|
' This is the code used to display the verbose help information.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub PrintHelp()
|
|
On Error Resume Next
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the PrintHelp() function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
Wscript.Echo "--------------------------------------------------------------------------------"
|
|
Wscript.Echo "AutodumpPlus Version " & VERSION
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Purpose:"
|
|
Wscript.Echo "AutodumpPlus automatically generates memory dumps or log files containing"
|
|
Wscript.Echo "scripted debug output usefull for troubleshooting N-tier WinDNA / .Net"
|
|
Wscript.Echo "applications."
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Since WinDNA / .Net applications often encompass multiple, interdependent"
|
|
Wscript.Echo "processes on one or more machines, when troubleshooting an 'application' hang"
|
|
Wscript.Echo "or crash it is often necessary to 'look' at all of the processes at the"
|
|
Wscript.Echo "same time. AutodumpPlus allows you to profile an application that is hanging"
|
|
Wscript.Echo "by taking 'snapshots' (memory dumps, or debug log files) of that application"
|
|
Wscript.Echo "and all of it's processes, all at the same time. Multiple 'snapshots' can"
|
|
Wscript.Echo "then be compared or analyzed to build a history or profile of an application"
|
|
Wscript.Echo "over time."
|
|
Wscript.Echo ""
|
|
Wscript.Echo "In addition to taking 'snapshots' of hung/non-responsive WinDNA / .Net "
|
|
Wscript.Echo "applications, AutodumpPlus can be used to troubleshoot applications that are"
|
|
Wscript.Echo "crashing or throwing unhandled exceptions which can lead to a crash."
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Usage:"
|
|
Wscript.Echo "AutodumpPlus has 3 modes of operation: 'Hang', 'Quick' and 'Crash' mode."
|
|
Wscript.Echo ""
|
|
Wscript.Echo "In 'Hang' mode, AutodumpPlus assumes that a process is hung and it will attach"
|
|
Wscript.Echo "a debugger to the process(s) specified on the command line with either the '-p'"
|
|
Wscript.Echo "or '-pn' or '-iis' switches. After the debugger is attached to the process(s)"
|
|
Wscript.Echo "AutodumpPlus will dump the memory of each process to a .dmp file for later"
|
|
Wscript.Echo "analysis with a debugger (such as WinDBG). In this mode, processes are paused"
|
|
Wscript.Echo "briefly while their memory is being dumped to a file and then resumed."
|
|
Wscript.Echo ""
|
|
Wscript.Echo "In 'Quick' mode AutodumpPlus assumes that a process is hung and it will attach"
|
|
Wscript.ECho "a debugger to the process(s) specified on the command line with either the '-p'"
|
|
Wscript.Echo "or '-pn' or '-iis' switches. After the debugger is attached to the process(s)"
|
|
Wscript.ECho "AutodumpPlus will create text files for each process, containing commonly"
|
|
Wscript.Echo "requested debug information, rather than dumping the entire memory for each"
|
|
Wscript.Echo " process. 'Quick' mode is generally faster than 'Hang' mode, but requires"
|
|
Wscript.Echo "symbols to be installed on the server where AutodumpPlus is running."
|
|
Wscript.Echo ""
|
|
Wscript.Echo "In 'Crash' mode, AutodumpPlus assumes that a process will crash and it will"
|
|
Wscript.ECho "attach a debugger to the process(s) specified on the command line with either"
|
|
Wscript.Echo "the '-p' or '-pn' or '-iis' switches. After the debugger is attached to the"
|
|
Wscript.Echo "process(s) AutodumpPlus will configure the debugger to log 'first chance'"
|
|
Wscript.Echo "exceptions to a text file. When a 'second chance' exception occurs"
|
|
Wscript.Echo "the processes memory is dumped to a .dmp file for analysis"
|
|
Wscript.Echo "with a debugger such as WinDBG. In this mode, a debugger remains attached to"
|
|
Wscript.Echo "the process(s) until the process exits or the debugger is exited by pressing"
|
|
Wscript.Echo "CTRL-C in the minimized debugger window. When the process crashes, or CTRL-C"
|
|
Wscript.Echo "is pressed it will need to be re-started."
|
|
Wscript.Echo ""
|
|
Wscript.Echo "The '-pageheap' switch is only valid in 'crash' mode and should only be used"
|
|
Wscript.Echo "when Pageheap.exe or GFlags.exe has been used to turn on NTDLL's heap"
|
|
Wscript.Echo "debugging options for a specific process, for the purpose of troubleshooting"
|
|
Wscript.Echo "heap corruption issues."
|
|
Wscript.Echo "This switch causes AutodumpPlus to produce a full memory dump when a "
|
|
Wscript.Echo "'debug break' exception is thrown. After the memory dumps is produced, "
|
|
Wscript.Echo "AutodumpPlus exits the debugger which kills the process being monitored."
|
|
Wscript.Echo "These exceptions can be thrown by DLL's that were compiled in debug mode,"
|
|
Wscript.Echo "or if the process being monitored is running with pageheap options enabled."
|
|
Wscript.Echo ""
|
|
Wscript.Echo "The '-quiet' switch can be used to suppress all modal dialog boxes that"
|
|
Wscript.Echo "AutodumpPlus displays. This is usefull if you are running AutodumpPlus"
|
|
Wscript.Echo "inside of a remot command shell. When this switch is used, AutodumpPlus"
|
|
Wscript.Echo "will log information to the event log rather than popping up dialog boxes"
|
|
Wscript.Echo "to the local desktop. Logging to the event log requires Windows Scripting"
|
|
Wscript.Echo "version 5.5 or later."
|
|
Wscript.Echo ""
|
|
Wscript.Echo "The '-o' switch can be used to supply an output directory for AutodumpPlus."
|
|
Wscript.Echo "AutodumpPlus will place all log files and memory dumps in the supplied"
|
|
Wscript.Echo "directory. Long file names should be placed inside of double quotes and"
|
|
Wscript.Echo "UNC paths are supported."
|
|
Wscript.Echo ""
|
|
Wscript.Echo "The '-notify' switch can be used to supply computer name for AutodumpPlus."
|
|
Wscript.Echo "to notify (via NET SEND) when a debugger is finished running."
|
|
Wscript.Echo "A username can be specified but supplying a computer name to notify"
|
|
Wscript.Echo "is generally more reliable."
|
|
Wscript.Echo ""
|
|
Call PrintUsage()
|
|
Wscript.quit 1
|
|
|
|
End Sub
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: PrintUsage
|
|
' This is the code used to print the usage information.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub PrintUsage()
|
|
On Error Resume Next
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the PrintUsage() function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
Wscript.Echo "AutodumpPlus " & VERSION & " Usage Information"
|
|
Wscript.Echo "Switches: '-hang', '-quick', '-crash', '-iis', '-p <PID>', '-pn <Process Name>"
|
|
Wscript.echo " '-pageheap', '-quiet', '-o <output directory>, '-notify <target>"
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Required: ('-hang', or '-quick', or '-crash') AND ('-iis' or '-p' or '-pn')"
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Optional: '-pageheap', '-quiet', '-o <outputdir>', '-notify <computer>'"
|
|
Wscript.Echo ""
|
|
Wscript.Echo "Examples: 'ADPlus -hang -iis', Produces memory dumps of IIS and all "
|
|
Wscript.Echo " MTS/COM+ packages currently running."
|
|
Wscript.ECho ""
|
|
Wscript.Echo " 'ADPlus -crash -p 1896', Attaches the debugger to process with PID"
|
|
Wscript.Echo " 1896, and monitors it for 1st and 2nd"
|
|
Wscript.Echo " chance access violations (crashes)."
|
|
Wscript.Echo ""
|
|
Wscript.Echo " 'ADPlus -quick -pn mmc.exe', Attaches the debugger to all instances"
|
|
Wscript.Echo " of MMC.EXE and dumps debug information"
|
|
Wscript.Echo " about these processes to a text file."
|
|
Wscript.Echo ""
|
|
Wscript.Echo " 'ADPlus -?' or 'ADPlus -help': Displays detailed help."
|
|
Wscript.Echo "-------------------------------------------------------------------------------"
|
|
Wscript.Echo "For more information on using AutodumpPlus, please refer to the following KB:"
|
|
Wscript.Echo "http://support.microsoft.com/support/kb/articles/q286/3/50.asp"
|
|
Wscript.quit 1
|
|
End Sub
|
|
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: FileExists
|
|
' This is the code used to verify if a file exists.
|
|
'
|
|
'---------------------------------------------------------------------------------------------
|
|
Function FileExists(strFile )
|
|
On Error Resume Next
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the FileExists() function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
FileExists = true
|
|
Dim objFileSystem
|
|
Set objFileSystem = CreateObject("Scripting.FileSystemObject")
|
|
FileExists = objFileSystem.FileExists(strFile)
|
|
set objFileSystem = nothing
|
|
|
|
End Function
|
|
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: CreateDirectory()
|
|
' This is the code used to create a directory on the file system or the network
|
|
' It checks to make sure you have proper permissions and displays/logs an error
|
|
' if you don't.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub CreateDirectory(strDirectory)
|
|
On Error Resume Next
|
|
|
|
Err.clear
|
|
Dim objFileSystem
|
|
Dim oFile
|
|
set objFileSystem = CreateObject("Scripting.FileSystemObject")
|
|
Set oFile = objFileSystem.CreateFolder(strDirectory)
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the CreateDirectory() function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
If err.number = -2147024784 Then 'The disk is full!
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In CreateDirectory(), Could not create the directory, the error number was: " & err.number & " and the error description was " & err.description
|
|
wscript.echo ""
|
|
End If
|
|
If QuietMode = False Then
|
|
objshell.popup "Could not create the " & strDirectory & " directory because the drive is full. Please free up some disk space and try running AutodumpPlus again!",,"AutodumpPlus",0
|
|
objShell.LogEvent 1, "Could not create the " & strDirectory & " directory because the drive is full. Please free up some disk space and try running AutodumpPlus again!"
|
|
Else
|
|
objShell.LogEvent 1, "Could not create the " & strDirectory & " directory because the drive is full. Please free up some disk space and try running AutodumpPlus again!"
|
|
wscript.echo "Could not create the " & strDirectory & " directory because the drive is full. Please free up some disk space and try running AutodumpPlus again!"
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
Wscript.Quit 1
|
|
ElseIf err.number = 76 Then 'Specified a subdirectory below a share that does not exist or path with more than one subdirectory that does not exist!
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In CreateDirectory(), Could not create the directory, the error number was: " & err.number
|
|
wscript.echo "In CreateDirectory(), the error description was " & err.description
|
|
End If
|
|
If QuietMode = False Then
|
|
objshell.popup "Could not create the " & strDirectory & " directory. If you are using the '-o' switch and specifying a UNC path, please ensure that the share and any sub-directories below the share you specified actually exist!",,"AutodumpPlus",0
|
|
objShell.LogEvent 1, "Could not create the " & strDirectory & " directory. If you are using the '-o' switch and specifying a UNC path, please ensure that the share and any sub-directories below the share you specified actually exist!"
|
|
Else
|
|
objShell.LogEvent 1, "Could not create the " & strDirectory & " directory. If you are using the '-o' switch and specifying a UNC path, please ensure that the share and any sub-directories below the share you specified actually exist!"
|
|
wscript.echo "Could not create the " & strDirectory & " directory. If you are using the '-o' switch and specifying a UNC path, please ensure that the share and any sub-directories below the share you specified actually exist!"
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
Wscript.quit 1
|
|
ElseIf err.number = 52 Then 'The share does not exist or can not connect to the UNC path.
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In CreateDirectory(), Could not create the directory, the error number was: " & err.number
|
|
wscript.echo "In CreateDirectory(), the error description was " & err.description
|
|
End If
|
|
If QuietMode = False Then
|
|
objshell.popup "Could not create the " & strDirectory & " directory. If you are using the '-o' switch and specifying a UNC path, please ensure that the UNC path you specified exists and that you are able to connect to it!",,"AutodumpPlus",0
|
|
objShell.LogEvent 1, "Could not create the " & strDirectory & " directory. If you are using the '-o' switch and specifying a UNC path, please ensure that the UNC path you specified exists and that you are able to connect to it!"
|
|
Else
|
|
objShell.LogEvent 1, "Could not create the " & strDirectory & " directory. If you are using the '-o' switch and specifying a UNC path, please ensure that the UNC path you specified exists and that you are able to connect to it!"
|
|
wscript.echo "Could not create the " & strDirectory & " directory. If you are using the '-o' switch and specifying a UNC path, please ensure that the UNC path you specified exists and that you are able to connect to it!"
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
Wscript.quit 1
|
|
ElseIf err.number <> 0 and err.number <> 58 Then 'Permissions problem
|
|
If DEBUGGING = TRUE Then
|
|
wscript.echo "In CreateDirectory(), Could not create the directory, the error number was: " & err.number & " and the error description was " & err.description
|
|
End If
|
|
If QuietMode = False Then
|
|
objshell.popup "Could not create the " & strDirectory & " directory. Please verify that you have permissions to create this directory and try running AutodumpPlus again!",,"AutodumpPlus",0
|
|
objShell.LogEvent 1, "Could not create the " & strDirectory & " directory. Please verify that you have permissions to create this directory and try running AutodumpPlus again!"
|
|
Else
|
|
objShell.LogEvent 1, "Could not create the " & strDirectory & " directory. Please verify that you have permissions to create this directory and try running AutodumpPlus again!"
|
|
wscript.echo "Could not create the " & strDirectory & " directory. Please verify that you have permissions to create this directory and try running AutodumpPlus again!"
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
Wscript.quit 1
|
|
|
|
End If
|
|
Set oFile = nothing
|
|
Set objFileSystem = nothing
|
|
End Sub
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: DeleteDirectory
|
|
' Code is used to delete a directory. Not sure if its used. May delete it after
|
|
' a code review.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub DeleteDirectory(strDirectory)
|
|
On Error Resume Next
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the DeleteDirectory() function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
Err.clear
|
|
Dim objFileSystem
|
|
Dim oFile
|
|
set objFileSystem = CreateObject("Scripting.FileSystemObject")
|
|
Set oFile = objFileSystem.DeleteFolder(strDirectory)
|
|
|
|
If (err.number <> 0) and (err.number <> 424) Then
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In DeleteDirectory(), after calling objFileSystem.DeleteFolder"
|
|
Wscript.echo "Directory to delete: " & strDirectory
|
|
Wscript.echo "err.number: " & err.number
|
|
Wscript.echo "err.description: " & err.description
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
If QuietMode = False Then
|
|
objshell.popup "Could not delete the " & strDirectory & " directory. This error can also occur if you have a file open in the " & strDirectory & " directory or if you don't have sufficient permissions. Please close any open files, check your permissions and try running AutodumpPlus again!",,"AutodumpPlus",0
|
|
Else
|
|
objShell.LogEvent 1, "Could not delete the " & strDirectory & " directory. This error can also occur if you have a file open in the " & strDirectory & " directory or if you don't have sufficient permissions. Please close any open files, check your permissions and try running AutodumpPlus again!"
|
|
wscript.echo "Could not delete the " & strDirectory & " directory. This error can also occur if you have a file open in the " & strDirectory & " directory or if you don't have sufficient permissions. Please close any open files, check your permissions and try running AutodumpPlus again!"
|
|
ErrorsDuringRuntime = True
|
|
End If
|
|
Wscript.quit 1
|
|
End If
|
|
|
|
set oFile = nothing
|
|
set objFileSystem = nothing
|
|
Err.clear
|
|
End Sub
|
|
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: DetectScriptEngine()
|
|
' This is the used to determine what script engine is currently running the script.
|
|
' It will prompt the user to switch the default script engine to cscript.exe if
|
|
' the script is running under wscript.exe.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub DetectScriptEngine ()
|
|
On Error Resume Next
|
|
|
|
Dim ScriptHost
|
|
Dim objShell
|
|
Dim CurrentPathExt
|
|
Dim EnvObject
|
|
Dim RegCScript
|
|
Dim RegPopupType ' This is used to set the pop-up box flags.
|
|
' I couldn't find the pre-defined names
|
|
RegPopupType = 32 + 4
|
|
set objShell = CreateObject("Wscript.Shell")
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the DetectScriptEngine() function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
On Error Resume Next
|
|
ScriptHost = WScript.FullName
|
|
ScriptHost = Right (ScriptHost, Len (ScriptHost) - InStrRev(ScriptHost,"\"))
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectScriptEngine(), the ScriptHost = " & ScriptHost
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
If (UCase (ScriptHost) = "WSCRIPT.EXE") Then
|
|
|
|
' Create a pop-up box and ask if they want to register cscript as the default host.
|
|
Set objShell = WScript.CreateObject ("WScript.Shell")
|
|
' -1 is the time to wait. 0 means wait forever.
|
|
If QuietMode = False Then
|
|
RegCScript = objShell.PopUp ("Wscript.exe is currently your default script interpreter. This script requires the Cscript.exe script interpreter to work properly. Would you like to register Cscript.exe as your default script interpreter for VBscript?", 0, "Register Cscript.exe as default script interpreter?", RegPopupType)
|
|
Else 'Running in Quiet mode, assume the user would WANT to change their script default script interpreter if they were prompted.
|
|
RegCscript = 6
|
|
End If
|
|
|
|
If (Err.Number <> 0) Then
|
|
ReportError ()
|
|
WScript.Echo "To run this script using the CScript.exe script interpreter, type: ""CScript.exe " & WScript.ScriptName & """"
|
|
WScript.Quit 1
|
|
|
|
End If
|
|
|
|
' Check to see if the user pressed yes or no. Yes is 6, no is 7
|
|
If (RegCScript = 6) Then
|
|
objShell.RegWrite "HKEY_CLASSES_ROOT\VBSFile\Shell\Open\Command\", "%WINDIR%\System32\CScript.exe //nologo ""%1"" %*", "REG_EXPAND_SZ"
|
|
objShell.RegWrite "HKEY_LOCAL_MACHINE\SOFTWARE\Classes\VBSFile\Shell\Open\Command\", "%WINDIR%\System32\CScript.exe //nologo ""%1"" %*", "REG_EXPAND_SZ"
|
|
' Check if PathExt already existed
|
|
CurrentPathExt = objShell.RegRead ("HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PATHEXT")
|
|
if Err.Number = &h80070002 Then
|
|
Err.Clear
|
|
Set EnvObject = objShell.Environment ("PROCESS")
|
|
CurrentPathExt = EnvObject.Item ("PATHEXT")
|
|
End If
|
|
|
|
objShell.RegWrite "HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PATHEXT", CurrentPathExt & ";.VBS", "REG_SZ"
|
|
|
|
If (Err.Number <> 0) Then
|
|
If QuietMode = True Then
|
|
objShell.Logevent 1, "Error trying to write the registry settings! The error number was: " & Err.Number & " and the error description was: " & err.description
|
|
Wscript.Quit (Err.Number)
|
|
Else
|
|
Wscript.echo "Error trying to write the registry settings! The error number was: " & Err.Number & " and the error description was: " & err.description
|
|
WScript.Quit (Err.Number)
|
|
End If
|
|
Else
|
|
If QuietMode = True Then
|
|
objShell.Logevent 0, "Since AutodumpPlus is running in 'Quiet' mode, the default script interpreter was automatically changed to CScript to ensure compatibility with this script. Autodump will now open a new command shell window and run ADPlus.vbs again with the argument passsed in on the command line. To change the default script engine back to Wscript, type 'wscript.exe //h:wscript' in a command shell."
|
|
Else
|
|
WScript.Echo "Successfully registered Cscript.exe as the default script interpreter! To change the default script engine back to Wscript, type 'wscript.exe //h:wscript' in a command shell."
|
|
End If
|
|
|
|
End If
|
|
Else 'The user does not want the script engine changed and didn't use the '-quiet' switch.
|
|
WScript.Echo "The default script interpreter was NOT changed to CScript. Press 'OK' to continue running AutodumpPlus with the Cscript.exe script interpreter. NOTE: AutodumpPlus will now open a new command shell to run ADPlus.vbs with the CScript script engine. A new command shell will be opened each time AutoDumpPlus is run until the default script interpreter is changed to Cscript.exe."
|
|
End If
|
|
|
|
Dim ProcString
|
|
Dim ArgIndex
|
|
Dim ArgObj
|
|
Dim Result
|
|
Dim StrShell
|
|
|
|
ProcString = "Cscript //nologo " & Chr(34) & WScript.ScriptFullName & Chr(34)
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectScriptEngine(), the ProcString = " & ProcString
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
Set ArgObj = WScript.Arguments
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectScriptEngine(), there were: " & ArgObj.Count & " arguments specified on the command line."
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
|
|
For ArgIndex = 0 To ArgObj.Count - 1
|
|
ProcString = ProcString & " " & ArgObj.Item (ArgIndex)
|
|
Next
|
|
|
|
strShell = "cmd /k " & ProcString
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectScriptEngine(), about to run the script with the following strShell: " & strShell
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
objShell.Run strShell,ACTIVATE_AND_DISPLAY,TRUE
|
|
|
|
WScript.Quit 1
|
|
End If
|
|
|
|
End Sub
|
|
|
|
|
|
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: DetectOSVersion
|
|
' This function is responsible for determining which operating system we are
|
|
' running on and to ensure its NT 4.0 SP4 or higher.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub DetectOSVersion()
|
|
On Error Resume Next
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the DetectOSVersion() function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
Dim objShell
|
|
Dim SPLevel
|
|
Dim Temp, cnt
|
|
|
|
err.clear
|
|
|
|
Set objShell = CreateObject("Wscript.Shell")
|
|
OSVer = objShell.RegRead("HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\CurrentVersion")
|
|
OSBuildNumber = objShell.RegRead("HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\CurrentBuildNumber")
|
|
If (Err.Number <> 0) Then
|
|
If QuietMode = True Then
|
|
objShell.Logevent 1, "There was an error trying to read the OS version information from the registry! The error number was: " & Err.Number & " and the error description was: " & err.description & " Please check the permissions on the key show and try running AutodumpPlus again."
|
|
Wscript.Quit (Err.Number)
|
|
Else
|
|
objShell.Popup "There was an error trying to read the OS version information from the registry! The error number was: " & Err.Number & " and the error description was: " & err.description & " Please check the permissions on the key show and try running AutodumpPlus again.",,"AutodumpPlus",0
|
|
WScript.Quit (Err.Number)
|
|
End If
|
|
Else
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectOSVersion(), after querying the registry for HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\CurrentVersion: "
|
|
Wscript.echo "In DetectOSVersion(), the OSVer = " & OSVer
|
|
Wscript.echo "In DetectOSVersion(), the OSBuildNumber = " & OSBuildNumber
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
If OSVer = "4.0" then
|
|
SPLevel = objShell.RegRead("HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\CSDVersion")
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectOSVersin(), SPLevel = " & SPLevel
|
|
End If
|
|
Temp = Split(SPLevel,",")
|
|
If UBound(Temp) <> 0 Then 'The customer must not have a released service pack, make a best effor to get the version.
|
|
Wscript.echo " Temp: " & Temp(0) & Temp(1)
|
|
|
|
For cnt = 0 to UBound(Temp)
|
|
If instr(1,Temp(cnt),"sp",1) <> 0 then
|
|
SPLevel = Right(Temp(cnt), 1)
|
|
Wscript.echo "SPlevel = " & SPlevel
|
|
exit for
|
|
else
|
|
'continue to the next string in the list.....
|
|
End if
|
|
|
|
Next
|
|
|
|
Else
|
|
'Customer has a released version of the service pack, get the SP number.
|
|
SPLevel = Right(SPLevel, 1)
|
|
|
|
End If
|
|
|
|
If SPLevel < 4 then
|
|
Wscript.echo "Autodump.vbs requires NT 4.0 Service Pack 4 or higher, or Windows 2000 in order to run."
|
|
Wscript.quit 1
|
|
end if
|
|
End if
|
|
End If
|
|
|
|
|
|
End sub
|
|
|
|
|
|
|
|
'---------------------------------------------------------------------------------------------
|
|
' Function: DetectIISVersion
|
|
' This function is responsible for determining which version of IIS we are
|
|
' running on. Since the '-iis' switch does not work on IIS 3.0, AutodumpPlus
|
|
' checks for IIS 3.0 or lower in the registry and does not allow the switch to be
|
|
' used. If the version of IIS is greater than 5.x, AutodumpPlus also does not
|
|
' allow the switch to be used as IIS 6.0 was not tested in time for this release.
|
|
'---------------------------------------------------------------------------------------------
|
|
Sub DetectIISVersion()
|
|
On Error Resume Next
|
|
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo ""
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo "In the DetectIISVersion() function . . ."
|
|
Wscript.echo "-----------------------------------"
|
|
Wscript.echo ""
|
|
End If
|
|
On Error Resume Next
|
|
Dim objShell
|
|
Dim AccessDeniedIIS4
|
|
Dim AccessDeniedIIS3
|
|
Dim NotFound
|
|
Dim Installed
|
|
Dim IIS3
|
|
Dim IIS4
|
|
Dim IIS4Key
|
|
Dim IIS3Key
|
|
|
|
NotFound = True
|
|
AccessDeniedIIS4 = False
|
|
AccessDeniedIIS3 = False
|
|
IIS3 = False
|
|
IIS4 = False
|
|
Installed = False
|
|
IIS4Key = "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\InetStp\VersionString"
|
|
IIS3Key = "HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Inetsrv\CurrentVersion\ServiceName"
|
|
Set objShell = CreateObject("Wscript.Shell")
|
|
'Check the IIS 4.0 and 5.x registry key to see if the user is running IIS 4.0 or 5.0
|
|
IISVer = objShell.RegRead(IIS4Key)
|
|
If err.number = -2147024894 Then 'The key was not found, check for IIS 3.0
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectIISVersion(), after querying the registry for: " & IIS4Key
|
|
Wscript.echo "In DetectOSVersion(), the key was not found, checking for IIS 3.0"
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
err.clear
|
|
IISVer = objShell.RegRead(IIS3Key)
|
|
If err.number = -2147024891 Then
|
|
'AutodumpPlus doesn't have permissions to read IIS 3.0's registry version key.
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectIISVersion(), after querying the registry for: " & IIS3Key
|
|
Wscript.echo "In DetectOSVersion(), access was denied trying to query the key."
|
|
Wscript.echo ""
|
|
End If
|
|
AccessDeniedIIS3 = True
|
|
ElseIf err.number = -2147024894 Then
|
|
'IIS 3.0 or higher is not installed.
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectIISVersion(), after querying the registry for: " & IIS3Key
|
|
Wscript.echo "In DetectIISVersion(), IIS 3.0, 4.0, or 5.0 were not detected. No IIS Key's exist in the registry."
|
|
Wscript.echo ""
|
|
End If
|
|
IISVer = "Not found"
|
|
Notfound = True
|
|
Installed = False
|
|
ElseIf err.number = 0 Then
|
|
'IIS 3.0 is installed and the version key can be read.
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectIISVersion(), after querying the registry for: " & IIS3Key
|
|
Wscript.echo "In DetectIISVersion(), the IIS3Key exists and can be read. Running either IIS 2.0 or 3.0."
|
|
Wscript.echo ""
|
|
End If
|
|
Installed = True
|
|
IIS3 = True
|
|
AccessDeniedIIS3 = False
|
|
Else
|
|
'Some other error has occurred accessing the version key's. Display an error and exit gracefully.
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectIISVersion(), after querying the registry for: " & IIS3Key
|
|
Wscript.echo "In DetectIISVersion(), There was an unknown problem accessing the registry."
|
|
Wscript.echo ""
|
|
End If
|
|
Wscript.echo "There was an error reading the registry. The error number was: " & err.number & " and the error description was: " & err.description
|
|
Wscript.quit (err.number)
|
|
End If
|
|
ElseIf err.number = -2147024891 Then 'They are running IIS 4.0 or 5.x (the key was found) but they don't have permissions
|
|
'AutodumpPlus doesn't have the proper permissions to read either the IIS 4.0 or 5.x registry keys but they exist.
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectIISVersion(), after querying the registry for: " & IIS4Key
|
|
Wscript.echo "In DetectIISVersion(), access was denied trying to query the key."
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
AccessDeniedIIS4 = True
|
|
ElseIf err.number = 0 Then
|
|
If InStr(IISVer,"4") <> 0 or InStr(IISVer,"5") <>0 or InStr(IISVer,"6") <>0 Then
|
|
'IIS 4.0, 5.x, or 6.0 is installed and AutodumpPlus can access the version key.
|
|
IIS4 = True
|
|
Installed = True
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectIISVersion(), after querying the registry for: " & IIS4Key
|
|
Wscript.echo "In DetectIISVersion(), IIS 4.0, 5.x, or 6.0 was found."
|
|
Wscript.echo ""
|
|
End If
|
|
Else
|
|
'AutodumpPlus has detected a newer version of IIS that has not been tested. Display an error and disable the '-iis' switch to be safe.
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectIISVersion(), after querying the registry for: " & IIS4Key
|
|
Wscript.echo "In DetectIISVersion(), ADPlus has detected an unsupported version of IIS (possibly IIS 7.0 or higher)."
|
|
Wscript.echo ""
|
|
End If
|
|
|
|
If QuietMode = False Then
|
|
objShell.popup "You appear to have IIS " & IISVer & " installed. This has not been tested with the '-iis' switch. Please run AutodumpPlus again, without the '-iis' switch.",,"AutodumpPlus",0
|
|
Wscript.quit
|
|
Else
|
|
wscript.echo "You appear to have IIS " & IISVer & " installed. This has not been tested with the '-iis' switch. Please run AutodumpPlus again, without the '-iis' switch."
|
|
objShell.logevent 1, "You appear to have IIS " & IISVer & " installed. This has not been tested with the '-iis' switch. Please run AutodumpPlus again, without the '-iis' switch."
|
|
Wscript.quit
|
|
End If
|
|
End If
|
|
Else
|
|
If DEBUGGING = TRUE Then
|
|
Wscript.echo "In DetectIISVersion(), after querying the registry for: " & IIS3Key
|
|
Wscript.echo "In DetectIISVersion(), There was an unknown problem accessing the registry."
|
|
Wscript.echo ""
|
|
End If
|
|
Wscript.echo "There was an error reading the registry"
|
|
Wscript.quit (err.number)
|
|
End If
|
|
|
|
|
|
If AccessDeniedIIS3 = True and IISMode = True Then
|
|
If QuietMode = False Then
|
|
objShell.popup "You appear to be running IIS 3.0 or lower, however AutodumpPlus had trouble verifying the IIS version in the registry at the following location: '" & IIS3Key & "', because of a permissions problem. The '-IIS' switch only works on IIS 4.0 or higher. If you are trying to monitor IIS 2.0 or IIS 3.0 please using the '-pn' switch to monitor inetinfo.exe.",,"AutodumpPlus",0
|
|
Wscript.quit 1
|
|
Else
|
|
wscript.echo "You appear to be running IIS 3.0 or lower, however AutodumpPlus had trouble verifying the IIS version in the registry at the following location: '" & IIS3Key & "', because of a permissions problem. The '-IIS' switch only works on IIS 4.0 or higher. If you are trying to monitor IIS 2.0 or IIS 3.0 please using the '-pn' switch to monitor inetinfo.exe."
|
|
objShell.LogEvent 1, "You appear to be running IIS 3.0 or lower, however AutodumpPlus had trouble verifying the IIS version in the registry at the following location: '" & IIS3Key & "', because of a permissions problem. The '-IIS' switch only works on IIS 4.0 or higher. If you are trying to monitor IIS 2.0 or IIS 3.0 please using the '-pn' switch to monitor inetinfo.exe."
|
|
Wscript.quit 1
|
|
End If
|
|
|
|
ElseIf AccessDeniedIIS4 = True and IISMode = True Then
|
|
If QuietMode = False Then
|
|
objShell.popup "You appear to be running IIS 4.0 or higher, however AutodumpPlus had trouble verifying the IIS version in the registry at the following location: '" & IIS4Key & "', because of a permissions problem. The '-IIS' switch only works on IIS 4.0 or higher. If you are trying to monitor IIS 2.0 or IIS 3.0 please using the '-pn' switch to monitor inetinfo.exe.",,"AutodumpPlus",0
|
|
Wscript.quit 1
|
|
Else
|
|
wscript.echo "You appear to be running IIS 4.0 or higher, however AutodumpPlus had trouble verifying the IIS version in the registry at the following location: '" & IIS4Key & "', because of a permissions problem. The '-IIS' switch only works on IIS 4.0 or higher. If you are trying to monitor IIS 2.0 or IIS 3.0 please using the '-pn' switch to monitor inetinfo.exe."
|
|
objShell.logevent 1, "You appear to be running IIS 4.0 or higher, however AutodumpPlus had trouble verifying the IIS version in the registry at the following location: '" & IIS4Key & "', because of a permissions problem. The '-IIS' switch only works on IIS 4.0 or higher. If you are trying to monitor IIS 2.0 or IIS 3.0 please using the '-pn' switch to monitor inetinfo.exe."
|
|
Wscript.quit 1
|
|
|
|
End If
|
|
ElseIf IIS3 = True AND IISMode = True Then
|
|
If QuietMode = False then
|
|
objShell.popup "You have specified the '-iis' switch, however you appear to be running " & IISVer & ". The '-iis' switch only works with IIS 4.0 and higher.",,"Autodump",0
|
|
Wscript.quit 1
|
|
Else
|
|
wscript.echo "You have specified the '-iis' switch, however you appear to be running " & IISVer & ". The '-iis' switch only works with IIS 4.0 and higher."
|
|
objShell.logevent 1, "You have specified the '-iis' switch, however you appear to be running " & IISVer & ". The '-iis' switch only works with IIS 4.0 and higher."
|
|
Wscript.quit 1
|
|
End if
|
|
ElseIf Installed = False AND IISMode = True Then
|
|
If QuietMode = False then
|
|
objShell.popup "You have specified the '-iis' switch, however you do not appear to be running a supported version of IIS. The '-iis' switch only works with IIS 4.0 and higher.",,"Autodump",0
|
|
Wscript.quit 1
|
|
Else
|
|
wscript.echo "You have specified the '-iis' switch, however you do not appear to be running a supported version of IIS. The '-iis' switch only works with IIS 4.0 and higher."
|
|
objShell.logevent 1, "You have specified the '-iis' switch, however you do not appear to be running a supported version of IIS. The '-iis' switch only works with IIS 4.0 and higher."
|
|
Wscript.quit 1
|
|
End if
|
|
|
|
End If
|
|
|
|
|
|
Set objShell = nothing
|
|
End sub |