/* Copyright 1999 American Power Conversion, All Rights Reserverd
|
|
*
|
|
* Description:
|
|
* The ApcMiniDriver class provides an interface that is
|
|
* compatible with the MiniDriver interface for the Windows2000
|
|
* UPS service.
|
|
* The ApcMiniDriver makes use of a modified
|
|
* PowerChute plus UPS service. This modified service has had
|
|
* all of the networking, data logging, and flex manager code
|
|
* removed. All that is left is the modeling and monitoring of
|
|
* the connected UPS system. It is assumed that a "smart"
|
|
* signalling UPS is connected.
|
|
* The ApcMiniDriver class is also responsible for filling in
|
|
* the advanced registry settings, battery replacement condition,
|
|
* serial #, firmware rev, etc...
|
|
*
|
|
* Revision History:
|
|
* mholly 14Apr1999 Created
|
|
* mholly 16Apr1999 Convert data from UPS into wide characters
|
|
* if UNICODE is defined
|
|
* mholly 19Apr1999 remove registry updates of utility line state
|
|
* mholly 20Apr1999 no longer updating model/vendor in registry
|
|
* mholly 26Apr1999 convert RUN_TIME_REMAINING to minutes before
|
|
* updating the registry - also only update the
|
|
* runtime in the onRuntimeTimer method
|
|
* mholly 12May1999 no longer taking aCommPort parameter in UPSInit
|
|
*
|
|
*/
|
|
|
|
#include "cdefine.h"
|
|
|
|
#include <windows.h>
|
|
#include <tchar.h>
|
|
#include <stdio.h>
|
|
#include <stdlib.h>
|
|
|
|
#include "apcdrvr.h"
|
|
#include "apcups.h"
|
|
#include "ntsrvap.h"
|
|
#include "event.h"
|
|
#include "timerman.h"
|
|
#include "codes.h"
|
|
#include "tokenstr.h"
|
|
|
|
extern "C"{
|
|
#include "upsreg.h"
|
|
}
|
|
|
|
// Separator used for the shutdown delay allowed values
|
|
#define SHUTDOWN_DELAY_SEPARATOR ","
|
|
#define LOW_BATT_DURATION_SEPARATOR ","
|
|
#define SECONDS_TO_MINUTES 60
|
|
|
|
/**
|
|
* ApcMiniDriver
|
|
*
|
|
* Description:
|
|
* Constructor - initializes all data members
|
|
*
|
|
* Parameters:
|
|
* None
|
|
*
|
|
* Returns:
|
|
* N/A
|
|
*
|
|
*/
|
|
ApcMiniDriver::ApcMiniDriver()
|
|
: theState(UPS_ONLINE),
|
|
theStateChangedEvent(NULL),
|
|
theReplaceBatteryState(UPS_BATTERYSTATUS_UNKNOWN),
|
|
theUpsApp(NULL),
|
|
theRunTimeTimer(0),
|
|
theOnBatteryRuntime(-1),
|
|
theBatteryCapacity(-1)
|
|
{
|
|
}
|
|
|
|
|
|
/**
|
|
* ~ApcMiniDriver
|
|
*
|
|
* Description:
|
|
* Destructor - does nothing, must call
|
|
* UPSStop prior to destructor
|
|
*
|
|
* Parameters:
|
|
* None
|
|
*
|
|
* Returns:
|
|
* N/A
|
|
*
|
|
*/
|
|
ApcMiniDriver::~ApcMiniDriver()
|
|
{
|
|
}
|
|
|
|
|
|
/**
|
|
* UPSInit
|
|
*
|
|
* Description:
|
|
* Must be the first method called on the object
|
|
* Failing to call UPSInit will result in an object
|
|
* in an unstable state
|
|
*
|
|
* Parameters:
|
|
* aCommPort: not used
|
|
*
|
|
* Returns:
|
|
* UPS_INITOK: initalized successfully
|
|
* UPS_INITUNKNOWNERROR: initialization failed
|
|
*
|
|
*/
|
|
DWORD ApcMiniDriver::UPSInit()
|
|
{
|
|
DWORD init_err = UPS_INITOK;
|
|
|
|
theStateChangedEvent = CreateEvent(NULL, FALSE, FALSE, NULL);
|
|
|
|
if (!theStateChangedEvent) {
|
|
init_err = UPS_INITUNKNOWNERROR;
|
|
}
|
|
|
|
if ((UPS_INITOK == init_err) &&
|
|
(ErrNO_ERROR != initalizeUpsApplication())) {
|
|
init_err = UPS_INITUNKNOWNERROR;
|
|
}
|
|
|
|
if (UPS_INITOK != init_err) {
|
|
UPSStop();
|
|
}
|
|
|
|
return init_err;
|
|
}
|
|
|
|
|
|
/**
|
|
* UPSStop
|
|
*
|
|
* Description:
|
|
* must be called to cleanup the object, after
|
|
* this call completes the only valid method
|
|
* call is UPSInit() or the destructor
|
|
*
|
|
* Parameters:
|
|
* None
|
|
*
|
|
* Returns:
|
|
* None
|
|
*
|
|
*/
|
|
void ApcMiniDriver::UPSStop()
|
|
{
|
|
UPSCancelWait();
|
|
cleanupUpsApplication();
|
|
|
|
if (theStateChangedEvent) {
|
|
CloseHandle(theStateChangedEvent);
|
|
theStateChangedEvent = NULL;
|
|
}
|
|
}
|
|
|
|
|
|
/**
|
|
* UPSWaitForStateChange
|
|
*
|
|
* Description:
|
|
* Blocks until the state of the UPS differs
|
|
* from the value passed in via aState or
|
|
* anInterval milliseconds has expired. If
|
|
* anInterval has a value of INFINITE this
|
|
* function will never timeout
|
|
*
|
|
* Parameters:
|
|
* aState: defines the state to wait for a change from,
|
|
* possible values:
|
|
* UPS_ONLINE
|
|
* UPS_ONBATTERY
|
|
* UPS_LOWBATTERY
|
|
* UPS_NOCOMM
|
|
*
|
|
* anInterval: timeout in milliseconds, or INFINITE for
|
|
* no timeout interval
|
|
*
|
|
* Returns:
|
|
* None
|
|
*
|
|
*/
|
|
void ApcMiniDriver::UPSWaitForStateChange(DWORD aLastState, DWORD anInterval)
|
|
{
|
|
if (aLastState == theState) {
|
|
//
|
|
// wait for a state change from the UPS
|
|
//
|
|
if (theStateChangedEvent) {
|
|
WaitForSingleObject(theStateChangedEvent, anInterval);
|
|
}
|
|
}
|
|
}
|
|
|
|
|
|
/**
|
|
* UPSGetState
|
|
*
|
|
* Description:
|
|
* returns the current state of the UPS
|
|
*
|
|
* Parameters:
|
|
* None
|
|
*
|
|
* Returns:
|
|
* possible values:
|
|
* UPS_ONLINE
|
|
* UPS_ONBATTERY
|
|
* UPS_LOWBATTERY
|
|
* UPS_NOCOMM
|
|
*
|
|
*/
|
|
DWORD ApcMiniDriver::UPSGetState()
|
|
{
|
|
return theState;
|
|
}
|
|
|
|
|
|
/**
|
|
* UPSCancelWait
|
|
*
|
|
* Description:
|
|
* interrupts pending calls to UPSWaitForStateChange
|
|
* without regard to timout or state change
|
|
*
|
|
* Parameters:
|
|
* None
|
|
*
|
|
* Returns:
|
|
* None
|
|
*
|
|
*/
|
|
void ApcMiniDriver::UPSCancelWait()
|
|
{
|
|
if (theStateChangedEvent) {
|
|
SetEvent(theStateChangedEvent);
|
|
}
|
|
}
|
|
|
|
|
|
/**
|
|
* UPSTurnOff
|
|
*
|
|
* Description:
|
|
* Attempts to turn off the outlets on the UPS
|
|
* after the specified delay. This method querries the
|
|
* UPS for the allowed shutdown delays and sets the
|
|
* delay to one of the following:
|
|
* 1. aTurnOffDelay if it exactly matches one of the allowed values
|
|
* 2. the next highest value after aTurnOffDelay, if one exists
|
|
* 3. the highest allowed value, if aTurnOffDelay is larger than all of
|
|
* the allowed values.
|
|
* If no allowed values are returned, the Shutdown Delay will not be set.
|
|
* Next the UPS is instructed to sleep until power is restored.
|
|
*
|
|
* Parameters:
|
|
* aTurnOffDelay: the minimum amount of time to wait before
|
|
* turning off the outlets on the UPS
|
|
*
|
|
* Returns:
|
|
* None
|
|
*
|
|
*/
|
|
void ApcMiniDriver::UPSTurnOff(DWORD aTurnOffDelay)
|
|
{
|
|
if (theUpsApp) {
|
|
char allowed_values[512];
|
|
|
|
// Retrieve the allowed shutdown delays from the UPS
|
|
theUpsApp->Get(ALLOWED_SHUTDOWN_DELAYS, allowed_values);
|
|
|
|
TokenString token_str(allowed_values, SHUTDOWN_DELAY_SEPARATOR);
|
|
PCHAR tok = token_str.GetCurrentToken();
|
|
|
|
// Set the shutdown delay if there are allowed values
|
|
if (tok) {
|
|
|
|
// Initialize counters
|
|
long requested_value = (long) aTurnOffDelay;
|
|
long max = atol(tok);
|
|
long last_closest = 0;
|
|
|
|
|
|
// Cycle through the allowed values looking for a suitable value
|
|
while (tok) {
|
|
long value = atol(tok);
|
|
|
|
// Check to see if this value is closest to the requested
|
|
if ( ((value >= requested_value) && (value < last_closest))
|
|
|| (last_closest < requested_value)) {
|
|
last_closest = value;
|
|
}
|
|
|
|
// Check to see if this value is the max value
|
|
if (value > max) {
|
|
max = value;
|
|
}
|
|
|
|
// Get the next value
|
|
tok = token_str.GetCurrentToken();
|
|
}
|
|
|
|
long shutdown_delay = last_closest;
|
|
|
|
if (last_closest < requested_value) {
|
|
// The requested value is larger than all of the values, use the max
|
|
shutdown_delay = max;
|
|
}
|
|
|
|
// Set the shutdown delay
|
|
char shutdown_delay_str[4];
|
|
sprintf(shutdown_delay_str, "%3.3u", shutdown_delay);
|
|
theUpsApp->Set(SHUTDOWN_DELAY, shutdown_delay_str);
|
|
}
|
|
|
|
// Signal the UPS to sleep
|
|
theUpsApp->UPSTurnOff();
|
|
}
|
|
}
|
|
|
|
|
|
/**
|
|
* Update
|
|
*
|
|
* Description:
|
|
* Update is called when theUpsApp has
|
|
* generated an Event for which this object
|
|
* has registered.
|
|
* Events are defined by a set of integer
|
|
* 'codes' defined in the file 'codes.h'
|
|
*
|
|
* Parameters:
|
|
* anEvent: a pointer to an Event object that
|
|
* defines the generated event
|
|
*
|
|
* Returns:
|
|
* ErrNO_ERROR
|
|
*
|
|
*/
|
|
INT ApcMiniDriver::Update(PEvent anEvent)
|
|
{
|
|
INT err = ErrNO_ERROR;
|
|
|
|
if (!anEvent) {
|
|
return err;
|
|
}
|
|
|
|
switch (anEvent->GetCode()) {
|
|
case UTILITY_LINE_CONDITION:
|
|
{
|
|
err = onUtilityLineCondition(anEvent);
|
|
}
|
|
break;
|
|
|
|
case BATTERY_REPLACEMENT_CONDITION:
|
|
{
|
|
err = onBatteryReplacementCondition(anEvent);
|
|
}
|
|
break;
|
|
|
|
case BATTERY_CONDITION:
|
|
{
|
|
err = onBatteryCondition(anEvent);
|
|
}
|
|
break;
|
|
|
|
case COMMUNICATION_STATE:
|
|
{
|
|
err = onCommunicationState(anEvent);
|
|
}
|
|
break;
|
|
|
|
case TIMER_PULSE:
|
|
{
|
|
err = onTimerPulse(anEvent);
|
|
}
|
|
break;
|
|
|
|
default:
|
|
{
|
|
err = UpdateObj::Update(anEvent);
|
|
}
|
|
break;
|
|
}
|
|
return err;
|
|
}
|
|
|
|
|
|
/**
|
|
* onUtilityLineCondition
|
|
*
|
|
* Description:
|
|
* Determines the current state of the power
|
|
* and reports any changes to the registry and
|
|
* to any threads pending on UPSWaitForStateChange
|
|
*
|
|
* Parameters:
|
|
* anEvent: pointer to an Event object that
|
|
* relates to a UTILITY_LINE_CONDITION event
|
|
*
|
|
* Returns:
|
|
* ErrNO_ERROR
|
|
*
|
|
*/
|
|
INT ApcMiniDriver::onUtilityLineCondition(PEvent anEvent)
|
|
{
|
|
DWORD state = atoi(anEvent->GetValue());
|
|
DWORD old_state = theState;
|
|
|
|
if (LINE_BAD == state) {
|
|
theState = UPS_ONBATTERY;
|
|
}
|
|
else {
|
|
theState = UPS_ONLINE;
|
|
}
|
|
|
|
if (old_state != theState) {
|
|
UPSCancelWait();
|
|
}
|
|
return ErrNO_ERROR;
|
|
}
|
|
|
|
|
|
/**
|
|
* onBatteryReplacementCondition
|
|
*
|
|
* Description:
|
|
* Determines the current replacement state of the
|
|
* battery and reports any changes to the registry
|
|
*
|
|
* Parameters:
|
|
* anEvent: pointer to an Event object that
|
|
* relates to a BATTERY_REPLACEMENT_CONDITION event
|
|
*
|
|
* Returns:
|
|
* ErrNO_ERROR
|
|
*
|
|
*/
|
|
INT ApcMiniDriver::onBatteryReplacementCondition(PEvent anEvent)
|
|
{
|
|
DWORD state = atoi(anEvent->GetValue());
|
|
DWORD old_state = theReplaceBatteryState;
|
|
|
|
if (BATTERY_NEEDS_REPLACING == state) {
|
|
theReplaceBatteryState = UPS_BATTERYSTATUS_REPLACE;
|
|
}
|
|
else {
|
|
theReplaceBatteryState = UPS_BATTERYSTATUS_GOOD;
|
|
}
|
|
|
|
if (old_state != theReplaceBatteryState) {
|
|
InitUPSStatusBlock();
|
|
SetUPSStatusBatteryStatus(theReplaceBatteryState);
|
|
SaveUPSStatusBlock(FALSE);
|
|
}
|
|
return ErrNO_ERROR;
|
|
}
|
|
|
|
|
|
/**
|
|
* onBatteryCondition
|
|
*
|
|
* Description:
|
|
* Determines the current charge-state of the battery
|
|
* and reports any changes to the registry and
|
|
* to any threads pending on UPSWaitForStateChange
|
|
*
|
|
* Parameters:
|
|
* anEvent: pointer to an Event object that
|
|
* relates to a BATTERY_CONDITION event
|
|
*
|
|
* Returns:
|
|
* ErrNO_ERROR
|
|
*
|
|
*/
|
|
INT ApcMiniDriver::onBatteryCondition(PEvent anEvent)
|
|
{
|
|
DWORD old_state = theState;
|
|
DWORD state = atoi(anEvent->GetValue());
|
|
|
|
//
|
|
// get the current line condition
|
|
// we only goto low battery if we
|
|
// are also on battery
|
|
//
|
|
char value[256];
|
|
theUpsApp->Get(UTILITY_LINE_CONDITION, value);
|
|
DWORD line_state = atoi(value);
|
|
|
|
if ((BATTERY_BAD == state) || (LOW_BATTERY == state)) {
|
|
|
|
if (LINE_BAD == line_state) {
|
|
theState = UPS_LOWBATTERY;
|
|
}
|
|
else {
|
|
theState = UPS_ONLINE;
|
|
}
|
|
}
|
|
else {
|
|
|
|
if (LINE_BAD == line_state) {
|
|
theState = UPS_ONBATTERY;
|
|
}
|
|
else {
|
|
theState = UPS_ONLINE;
|
|
}
|
|
}
|
|
|
|
if (old_state != theState) {
|
|
UPSCancelWait();
|
|
}
|
|
return ErrNO_ERROR;
|
|
}
|
|
|
|
|
|
/**
|
|
* onCommunicationState
|
|
*
|
|
* Description:
|
|
* Determines the communication state to the UPS
|
|
* If theState goes to UPS_NOCOMM we report the change
|
|
* to threads pending on UPSWaitForStateChange
|
|
* If the state is leaving UPS_NOCOMM, we
|
|
* reinitialize the registry with advanced data
|
|
* and then 'fake' power and battery condition
|
|
* events
|
|
*
|
|
* Parameters:
|
|
* anEvent: pointer to an Event object that
|
|
* relates to a COMMUNICATION_STATE event
|
|
*
|
|
* Returns:
|
|
* ErrNO_ERROR
|
|
*
|
|
*/
|
|
INT ApcMiniDriver::onCommunicationState(PEvent anEvent)
|
|
{
|
|
DWORD state = atoi(anEvent->GetValue());
|
|
|
|
if ((COMMUNICATION_LOST == state) ||
|
|
(COMMUNICATION_LOST_ON_BATTERY == state)) {
|
|
|
|
if (UPS_NOCOMM != theState) {
|
|
theState = UPS_NOCOMM;
|
|
UPSCancelWait();
|
|
}
|
|
}
|
|
else {
|
|
|
|
if (UPS_NOCOMM == theState) {
|
|
//
|
|
// need to re-initialize the UPS data, since
|
|
// when you lose comm, the user might plug in
|
|
// a new UPS system
|
|
//
|
|
initalizeAdvancedUpsData();
|
|
|
|
// Set the low battery warning threshold
|
|
setLowBatteryDuration();
|
|
|
|
//
|
|
// here we just ask the service what it thinks
|
|
// the current line/battery conditions are, and
|
|
// 'fake' an event to ourselves. This allows
|
|
// all line/battery state changes to be handled
|
|
// consistently in the same methods
|
|
//
|
|
char value[256];
|
|
theUpsApp->Get(UTILITY_LINE_CONDITION, value);
|
|
Event ulc_evt(UTILITY_LINE_CONDITION, value);
|
|
onUtilityLineCondition(&ulc_evt);
|
|
|
|
theUpsApp->Get(BATTERY_CONDITION, value);
|
|
Event batt_evt(BATTERY_CONDITION, value);
|
|
onBatteryCondition(&batt_evt);
|
|
}
|
|
}
|
|
return ErrNO_ERROR;
|
|
}
|
|
|
|
|
|
/**
|
|
* onTimerPulse
|
|
*
|
|
* Description:
|
|
* Retrieves the on-battery runtime and battery
|
|
* capacity from the UPS and updates the registry
|
|
* with the values if they differ from the last
|
|
* time this method was called
|
|
*
|
|
* Parameters:
|
|
* anEvent: pointer to an Event object that
|
|
* relates to a TIMER_PULSE event
|
|
*
|
|
* Returns:
|
|
* ErrNO_ERROR
|
|
*
|
|
*/
|
|
INT ApcMiniDriver::onTimerPulse(PEvent anEvent)
|
|
{
|
|
DWORD old_run_time = theOnBatteryRuntime;
|
|
DWORD old_batt_cap = theBatteryCapacity;
|
|
|
|
//
|
|
// get the current on-battery runtime
|
|
//
|
|
CHAR data[100];
|
|
if (theUpsApp->Get(RUN_TIME_REMAINING,data) == ErrNO_ERROR) {
|
|
//
|
|
// we get the RUN_TIME_REMAINING back in seconds
|
|
// the UPS applet expects the value to be in
|
|
// minutes -
|
|
theOnBatteryRuntime = atol(data) / 60;
|
|
}
|
|
|
|
//
|
|
// get the current battery capacity
|
|
//
|
|
if (theUpsApp->Get(BATTERY_CAPACITY,data) == ErrNO_ERROR) {
|
|
// we get the battery capacity back as a percentage
|
|
// the UPS applet expects only a whole number.
|
|
theBatteryCapacity = (long) atof(data);
|
|
}
|
|
|
|
|
|
if ((old_run_time != theOnBatteryRuntime) || (old_batt_cap != theBatteryCapacity)){
|
|
// One or more values changed, update the registry
|
|
InitUPSStatusBlock();
|
|
|
|
if (old_run_time != theOnBatteryRuntime) {
|
|
// Update run time remaining
|
|
SetUPSStatusRuntime(theOnBatteryRuntime);
|
|
}
|
|
|
|
if (old_batt_cap != theBatteryCapacity) {
|
|
SetUPSStatusBatteryCapacity(theBatteryCapacity);
|
|
}
|
|
|
|
SaveUPSStatusBlock(FALSE);
|
|
}
|
|
|
|
//
|
|
// must create another timer to update the
|
|
// value again
|
|
//
|
|
theRunTimeTimer =
|
|
_theTimerManager->SetTheTimer((ULONG)5,
|
|
anEvent,
|
|
this);
|
|
|
|
return ErrNO_ERROR;
|
|
}
|
|
|
|
|
|
/**
|
|
* initalizeAdvancedUpsData
|
|
*
|
|
* Description:
|
|
* Retrieves the advanced data from theUpsApp
|
|
* and forces an update to the registry with
|
|
* the fresh data
|
|
*
|
|
* Parameters:
|
|
* None
|
|
*
|
|
* Returns:
|
|
* ErrNO_ERROR
|
|
*
|
|
*/
|
|
INT ApcMiniDriver::initalizeAdvancedUpsData()
|
|
{
|
|
// Initialize all static registry data
|
|
InitUPSStatusBlock();
|
|
CHAR data[100];
|
|
TCHAR w_data[200];
|
|
|
|
|
|
theUpsApp->Get(CURRENT_FIRMWARE_REV,data);
|
|
#ifdef UNICODE
|
|
MultiByteToWideChar(CP_ACP, MB_PRECOMPOSED, data, -1,
|
|
w_data, (sizeof(w_data)/sizeof(TCHAR)));
|
|
#else
|
|
strcpy(w_data, data);
|
|
#endif
|
|
SetUPSStatusFirmRev(w_data);
|
|
|
|
|
|
theUpsApp->Get(UPS_SERIAL_NUMBER,data);
|
|
#ifdef UNICODE
|
|
MultiByteToWideChar(CP_ACP, MB_PRECOMPOSED, data, -1,
|
|
w_data, (sizeof(w_data)/sizeof(TCHAR)));
|
|
#else
|
|
strcpy(w_data, data);
|
|
#endif
|
|
SetUPSStatusSerialNum(w_data);
|
|
|
|
// Default utility power and battery status to GOOD
|
|
SetUPSStatusBatteryStatus(UPS_BATTERYSTATUS_GOOD);
|
|
|
|
SetUPSStatusBatteryCapacity(0);
|
|
|
|
SaveUPSStatusBlock(TRUE);
|
|
|
|
//
|
|
// dummy up a BATTERY_REPLACEMENT_CONDITION event,
|
|
// just to make sure we initialize the registry with
|
|
// valid data, since this is an event we will not
|
|
// be notified unless the state changes
|
|
//
|
|
theUpsApp->Get(BATTERY_REPLACEMENT_CONDITION, data);
|
|
Event replace_batt(BATTERY_REPLACEMENT_CONDITION, data);
|
|
onBatteryReplacementCondition(&replace_batt);
|
|
|
|
return ErrNO_ERROR;
|
|
}
|
|
|
|
|
|
/**
|
|
* initalizeUpsApplication
|
|
*
|
|
* Description:
|
|
* inits theUpsApp member with a new NTServerApplication
|
|
* object.
|
|
* Registers for the events that can be received
|
|
* in the Update method
|
|
* Initalizes the advanced UPS data in the registry,
|
|
* and starts the repeating event that triggers updates
|
|
* to get on-battery runtime data
|
|
*
|
|
* Parameters:
|
|
* None
|
|
*
|
|
* Returns:
|
|
* ErrNO_ERROR: init succeeded
|
|
* ErrMEMORY: theUpsApp could not be created
|
|
*
|
|
*/
|
|
INT ApcMiniDriver::initalizeUpsApplication()
|
|
{
|
|
INT err = ErrNO_ERROR;
|
|
|
|
//
|
|
// assume that the UPS is not on battery
|
|
// this matches the assumption made by
|
|
// the NTServerApplication class
|
|
//
|
|
theState = UPS_ONLINE;
|
|
theUpsApp = new NTServerApplication();
|
|
|
|
if (!theUpsApp) {
|
|
err = ErrMEMORY;
|
|
}
|
|
else {
|
|
theUpsApp->RegisterEvent(UTILITY_LINE_CONDITION, this);
|
|
theUpsApp->RegisterEvent(BATTERY_CONDITION, this);
|
|
theUpsApp->RegisterEvent(BATTERY_REPLACEMENT_CONDITION, this);
|
|
theUpsApp->RegisterEvent(COMMUNICATION_STATE, this);
|
|
|
|
err = theUpsApp->Start();
|
|
}
|
|
|
|
if (ErrNO_ERROR == err) {
|
|
initalizeAdvancedUpsData();
|
|
|
|
// Start the polling of UPS run time
|
|
if (!theRunTimeTimer) {
|
|
Event retry_event(TIMER_PULSE, TIMER_PULSE);
|
|
onTimerPulse(&retry_event);
|
|
}
|
|
}
|
|
return err;
|
|
}
|
|
|
|
|
|
/**
|
|
* cleanupUpsApplication
|
|
*
|
|
* Description:
|
|
* cleans up and destructs theUpsApp object. Sets
|
|
* member variables to the default values
|
|
*
|
|
*
|
|
* Parameters:
|
|
* None
|
|
*
|
|
* Returns:
|
|
* None
|
|
*
|
|
*/
|
|
void ApcMiniDriver::cleanupUpsApplication()
|
|
{
|
|
theState = UPS_ONLINE;
|
|
|
|
if (theUpsApp) {
|
|
theUpsApp->Quit();
|
|
delete theUpsApp;
|
|
theUpsApp = NULL;
|
|
}
|
|
theRunTimeTimer = 0;
|
|
theOnBatteryRuntime = -1;
|
|
}
|
|
|
|
/**
|
|
* setLowBatteryDuration
|
|
*
|
|
* Description:
|
|
* Sets the low battery duration to a value compatable with the
|
|
* UPSTurnOffWait registry key. This method querries the
|
|
* UPS for the allowed low battery durations and sets the
|
|
* duration to one of the following:
|
|
* 1. The value of UPSTurnOffWait if it exactly matches one of
|
|
* the allowed values
|
|
* 2. the next highest value after UPSTurnOffWait, if one exists
|
|
* 3. the highest allowed value, if UPSTurnOffWait is larger than
|
|
* all of the allowed values.
|
|
* If the UPSTurnOffWait is not set or no allowed values are returned,
|
|
* the low battery duration will not be set.
|
|
*
|
|
* Parameters:
|
|
* None
|
|
*
|
|
* Returns:
|
|
* None
|
|
*
|
|
*/
|
|
void ApcMiniDriver::setLowBatteryDuration() {
|
|
DWORD turn_off_wait;
|
|
|
|
InitUPSConfigBlock();
|
|
|
|
if ((GetUPSConfigTurnOffWait(&turn_off_wait) == ERROR_SUCCESS) && (theUpsApp)) {
|
|
char allowed_values[512];
|
|
|
|
// Retrieve the allowed low battery durations from the UPS
|
|
theUpsApp->Get(ALLOWED_LOW_BATTERY_DURATIONS, allowed_values);
|
|
|
|
TokenString token_str(allowed_values, LOW_BATT_DURATION_SEPARATOR);
|
|
PCHAR tok = token_str.GetCurrentToken();
|
|
|
|
// Set the low battery duration if there are allowed values
|
|
if (tok) {
|
|
|
|
// Initialize counters
|
|
long max = atol(tok);
|
|
long last_closest = 0;
|
|
long requested_value = 0;
|
|
if (turn_off_wait > 0) {
|
|
// Convert the value from seconds to minutes (rounded up)
|
|
requested_value = turn_off_wait / SECONDS_TO_MINUTES;
|
|
if ((turn_off_wait % SECONDS_TO_MINUTES) > 0) {
|
|
++requested_value;
|
|
}
|
|
}
|
|
|
|
|
|
// Cycle through the allowed values looking for a suitable value
|
|
while (tok) {
|
|
long value = atol(tok);
|
|
|
|
// Check to see if this value is closest to the requested
|
|
if ( ((value >= requested_value) && (value < last_closest))
|
|
|| (last_closest < requested_value)) {
|
|
last_closest = value;
|
|
}
|
|
|
|
// Check to see if this value is the max value
|
|
if (value > max) {
|
|
max = value;
|
|
}
|
|
|
|
// Get the next value
|
|
tok = token_str.GetCurrentToken();
|
|
}
|
|
|
|
long low_batt_duration = last_closest;
|
|
|
|
if (last_closest < requested_value) {
|
|
// The requested value is larger than all of the values, use the max
|
|
low_batt_duration = max;
|
|
}
|
|
|
|
// Set the shutdown delay
|
|
char low_batt_duration_str[4];
|
|
sprintf(low_batt_duration_str, "%2.2u", low_batt_duration);
|
|
theUpsApp->Set(LOW_BATTERY_DURATION, low_batt_duration_str);
|
|
}
|
|
}
|
|
}
|