windows-nt/Source/XPSP1/NT/drivers/smartcrd/scrcp8t/cp8tlog.mc
2020-09-26 16:20:57 +08:00

89 lines
2.6 KiB
MonkeyC

;/*++ BUILD Version: 0001 // Increment this if a change has global effects
;
;Copyright (c) 1993 Microsoft Corporation
;
;Module Name:
;
; scrcp8t.mc
;
;Abstract:
;
; Constant definitions for the I/O error code log values.
;
;Revision History:
;
;--*/
;
;#ifndef _CP8TLOG_
;#define _CP8TLOG_
;
;//
;// Status values are 32 bit values layed out as follows:
;//
;// 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1
;// 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0
;// +---+-+-------------------------+-------------------------------+
;// |Sev|C| Facility | Code |
;// +---+-+-------------------------+-------------------------------+
;//
;// where
;//
;// Sev - is the severity code
;//
;// 00 - Success
;// 01 - Informational
;// 10 - Warning
;// 11 - Error
;//
;// C - is the Customer code flag
;//
;// Facility - is the facility code
;//
;// Code - is the facility's status code
;//
;
MessageIdTypedef=NTSTATUS
SeverityNames=(Success=0x0:STATUS_SEVERITY_SUCCESS
Informational=0x1:STATUS_SEVERITY_INFORMATIONAL
Warning=0x2:STATUS_SEVERITY_WARNING
Error=0x3:STATUS_SEVERITY_ERROR
)
FacilityNames=(System=0x0
RpcRuntime=0x2:FACILITY_RPC_RUNTIME
RpcStubs=0x3:FACILITY_RPC_STUBS
Io=0x4:FACILITY_IO_ERROR_CODE
Smartcard=0x10:FACILITY_SCARD
)
MessageId=0x0001 Facility=Io Severity=Error SymbolicName=CP8_CANT_CONNECT_TO_SERIAL_PORT
Language=English
Can't open COM%2. It is either not available or used by another device.
.
MessageId=0x0002 Facility=Io Severity=Error SymbolicName=CP8_CANT_CREATE_DEVICE
Language=English
Device for Smart Card Reader cannot be created due to an internal error.
.
MessageId=0x0003 Facility=Io Severity=Error SymbolicName=CP8_NO_MEMORY
Language=English
Not enough memory available to create device.
.
MessageId=0x0004 Facility=Smartcard Severity=Error SymbolicName=CP8_BUFFER_TOO_SMALL
Language=English
Smart Card Data Buffer too small.
The internal data buffer for sending and receiving data is too small to hold all data.
.
MessageId=0x0005 Facility=Smartcard Severity=Warning SymbolicName=CP8_NO_SUCH_DEVICE
Language=English
No Bull CP8 Transac Smart Card Reader found.
To autodetect all Bull CP8 readers please
insert a smart card in each reader and
reboot the system.
.
MessageId=0x0006 Facility=Smartcard Severity=Informational SymbolicName=CP8_NEW_DEVICE_ADDED
Language=English
A Bull CP8 Smart Card Reader on %2 has been added to the system.
.
;#endif /* _CP8TLOG_ */