MSIPBOOTP-MIB DEFINITIONS ::= BEGIN
--
-- Microsoft(R) BOOTP for Internet Protocol MIB
--
-- This MIB defines the management information for the BOOTP
-- Protocol. The information in this MIB is divided
-- into 3 groups:
--
-- 1. Global Group
-- Contains the global information BOOTP protocol
-- Information contained in this group is independent of the interfaces
-- over which the protocol is enabled.
--
-- 2. Interface Group
-- Contains RIP configuration information and statistics specific
-- to each interface.
--
--
IMPORTS
enterprises, OBJECT-TYPE,
TimeTicks, Counter, IpAddress
FROM RFC1155-SMI
microsoft, software
FROM MSFT-MIB;
-- MSIPRIP2
-- microsoft OBJECT IDENTIFIER ::= { enterprises 311 }
-- software OBJECT IDENTIFIER ::= { microsoft 1 }
msipbootp OBJECT IDENTIFIER ::= { software 12 }
--
-- groups in MSIPRIP2
--
global OBJECT IDENTIFIER ::= { msipbootp 1 }
interface OBJECT IDENTIFIER ::= { msipbootp 2 }
--
-- BOOTP Global Group
--
-- Contains the global information for the BOOTP protocol
-- Information contained in this group is independent of the
-- interfaces over which the protocol is enabled.
--
-- Global information consists of scalar variables which can be
-- updated and table of DHCP/BOOTP servers to which packets will be
-- sent.
--
globalLoggingLevel OBJECT-TYPE
SYNTAX INTEGER {
none(1),
error(2),
warning(3),
information(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Information logged can be None, Error only, Error + Warning,
Error + Warn + Logging. This variable controls the amount
of information logged"
::= { global 1 }
globalMaxRecQueueSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum size to use for queueing incoming packets."
::= { global 2 }
globalServerCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of entries BOOTP server table"
::= { global 3 }
--
-- the DHCP/BOOTP Server Table
--
--
-- Entries in the BOOTP Server table are IP addresses of BOOTP servers
-- to which request packets are forwarded.
--
globalBOOTPServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF GlobalBOOTPServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of BOOTP servers to which packets are sent by this router"
::= { global 4 }
globalBOOTPServerEntry OBJECT-TYPE
SYNTAX GlobalBOOTPServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"BOOTP server entry. Contains the IP address of a BOOTP server"
INDEX { globalBOOTPServerAddr }
::= { globalBOOTPServerTable 1 }
GlobalBOOTPServerEntry ::=
SEQUENCE {
globalBOOTPServerAddr
IpAddress,
globalBOOTPServerTag
INTEGER
}
globalBOOTPServerAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of DHCP/BOOTP router"
::= { globalBOOTPServerEntry 1 }
globalBOOTPServerTag OBJECT-TYPE
SYNTAX INTEGER {
create(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"create : Creates an entry in the BOOTP Server table
delete : Deletes an entry in the BOOTP Server table
"
::= { globalBOOTPServerEntry 2 }
--
-- BOOTP Interface group
--
-- Contains BOOTP interface configuration information, BOOTP interface
-- statistics and BOOTP interface binding information. Each type of
-- information is stored in a table with one entry for each
-- interface over which BOOTP is enabled.
--
-- Asscociated with each entry in the Interface binding table is a
-- list of entries in the
--
-- Interface Address Table : List of address bound to an interface
--
--
-- Interface Statistics Table.
--
--
-- BOOTP statistics for each interface. Statistics include
-- number of send/receive failures
-- number of ARP Update Failures
-- number of requests/replies received/discarded,
--
ifStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of BOOTP statistics for interfaces"
::= { interface 1 }
ifStatsEntry OBJECT-TYPE
SYNTAX IfStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"BOOTP interface statistics entry.
Each entry contains counts of send/receive failures, requests/relies
received/discarded, and ARP Update failures"
INDEX { ifSEIndex }
::= { ifStatsTable 1 }
IfStatsEntry ::=
SEQUENCE {
ifSEIndex
INTEGER,
ifSEState
INTEGER,
ifSESendFailures
Counter,
ifSEReceiveFailures
Counter,
ifSEArpUpdateFailures
Counter,
ifSERequestReceiveds
Counter,
ifSERequestDiscards
Counter,
ifSEReplyReceiveds
Counter,
ifSEReplyDiscards
Counter
}
ifSEIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index for the BOOTP interface Statistics table"
::= { ifStatsEntry 1 }
ifSEState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
bound(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current state of BOOTP on this interface."
::= { ifStatsEntry 2 }
ifSESendFailures OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times a failure occurred while attempting to send a
packet on this interface."
::= { ifStatsEntry 3 }
ifSEReceiveFailures OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times a failure occurred while attempting to receive
a packet on this interface."
::= { ifStatsEntry 4 }
ifSEArpUpdateFailures OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times a failure occurred while attempting to
update the ARP cache on this interface."
::= { ifStatsEntry 5 }
ifSERequestReceiveds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of BOOTP REQUEST packets received on this interface."
::= { ifStatsEntry 6 }
ifSERequestDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of BOOTP REQUEST packets discarded on this interface."
::= { ifStatsEntry 7 }
ifSEReplyReceiveds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of BOOTP REPLY packets received on this interface."
::= { ifStatsEntry 8 }
ifSEReplyDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of BOOTP REPLY packets discarded due to errors in the header."
::= { ifStatsEntry 9 }
--
-- BOOTP Interface Configuration Table.
--
--
-- BOOTP Interface config includes the interface setting for :
--
-- Relay Modes, max hop count and minimum seconds since boot
--
--
ifConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"BOOTP Interface configuration table. List of subnets that require
separate configuration in BOOTP."
::= { interface 2 }
ifConfigEntry OBJECT-TYPE
SYNTAX IfConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"BOOTP configuration entry for an interface. A single routing domain in a
single subnet."
INDEX { ifCEIndex }
::= { ifConfigTable 1 }
IfConfigEntry ::=
SEQUENCE {
ifCEIndex
INTEGER,
ifCEState
INTEGER,
ifCERelayMode
INTEGER,
ifCEMaxHopCount
INTEGER,
ifCEMinSecondsSinceBoot
INTEGER
}
ifCEIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index for BOOTP interface config. table."
::= { ifConfigEntry 1 }
ifCEState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
bound(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current state of BOOTP on this interface."
::= { ifConfigEntry 2 }
ifCERelayMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Relay Mode for BOOTP request/reply packets "
DEFVAL { enabled }
::= { ifConfigEntry 3 }
ifCEMaxHopCount OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Each time a BOOTP request is forwarded by the BOOTP relay agent
the request packet's hop count is incremented. If the number of
hops traversed by the packet exceeds the max hop count configured
on a relay agent the request packet is discarded by that relay agent."
DEFVAL { 4 }
::= { ifConfigEntry 4 }
ifCEMinSecondsSinceBoot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Each BOOTP request sent by a client contains the time since the client
has booted. If the time since boot for the client exceeds the
configured value of ifCEMinSecondsSinceBoot on a relay agent,
the relay agent will forward the request. Otherwise it will discard
the request."
DEFVAL { 4 }
::= { ifConfigEntry 5 }
--
-- Interface Binding Table.
--
--
-- This table stores information pertaining to the binding state and the
-- number of IP addresses bound to an interface.
--
-- The list of IP address bound to an interface is maintained in the
-- Interface Address Table
--
ifBindingTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfBindingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table containing binding information for each interface."
::= { interface 3 }
ifBindingEntry OBJECT-TYPE
SYNTAX IfBindingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Binding information entry for an interface"
INDEX { ifBindingIndex }
::= { ifBindingTable 1 }
IfBindingEntry ::=
SEQUENCE {
ifBindingIndex
INTEGER,
ifBindingState
INTEGER,
ifBindingAddrCount
INTEGER
}
ifBindingIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index for an interface entry in the binding table"
::= { ifBindingEntry 1 }
ifBindingState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
bound(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of the interface binding"
::= { ifBindingEntry 2 }
ifBindingAddrCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of IP address bound to this interface. This is also the
number of entries in the Interface Address Table corresponding
to this interface."
::= { ifBindingEntry 3 }
--
-- Interface Address Table
--
--
-- The Interface Address Table contains the list of address bound to
-- each interface.
--
-- This table is indexed by an interface number and an IP address.
--
ifAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfAddressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of IP addresses bound to interfaces"
::= { interface 4 }
ifAddressEntry OBJECT-TYPE
SYNTAX IfAddressEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry for an IP address for an interface"
INDEX { ifAEIfIndex, ifAEAddress, ifAEMask }
::= { ifAddressTable 1 }
IfAddressEntry ::=
SEQUENCE {
ifAEIfIndex
INTEGER,
ifAEAddress
IpAddress,
ifAEMask
IpAddress
}
ifAEIfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index corresponding to the Interface with which this entry
is associated."
::= { ifAddressEntry 1 }
ifAEAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ip address bound to the associated interface."
::= { ifAddressEntry 2 }
ifAEMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Address Mask associated with the IP address contained in the
corresponding ifAEAddress field."
::= { ifAddressEntry 3 }
END